Gene Fuller wrote:
If you refuse to accept standard technical conventions, then there is
little hope of getting others to agree with you.
Gene, have you stopped beating your wife? Your usual ad
hominem attack completely devoid of any technical content
is duly noted.
In a one second long lossless transmission line where the
forward power is 200W and the reflected power is 100W, it
can be proved that the source has supplied 300 joules that
have not been accepted by the load. If those joules are not
contained in the forward and reflected waves, where are they?
--
73, Cecil
http://www.qsl.net/w5dxp