View Single Post
  #9   Report Post  
Old November 3rd 03, 04:09 PM
Tom Bruhns
 
Posts: n/a
Default

"Reg Edwards" wrote in message ...
"Tom Bruhns" wrote "Reg Edwards"
The velocity factor of ALL solid polyethylene coax cable, regardless of
impedance, is 0.665


================================

And this comes from someone who I could swear posted not long ago a
table that had velocity factors for solid polyethylene cable that were
significantly different from this magic number?

....
===============================

Your para. 1. You can swear till you're appoplectic black and blue in the
face - it wasn't me. I'm not THAT stupid. So who was it then?

....

----
Reg.


Hi Reg...

Well, the Google archive says it was from you. Perhaps you DO have
someone else posting under your name.

See below. Or is the "VF" column not actually velocity factor? OTOH,
I do agree with the posting below, that at low frequencies, beta
becomes dependent more on R than on L, and thus the VF changes.

Cheers,
Tom


From: Reg Edwards )
Subject: Coax Cable vs Freqency

View this article only
Newsgroups: rec.radio.amateur.antenna
Date: 2003-08-12 17:41:24 PST

For anyone who may be interested.

Typical of RG-58 and RG-11 type cables.
Zo = Ro - jXo
Xo is always negative.
Angle of Zo in degrees. Always negative.
VF = relative velocity.

Freq Ro jXo Angle VF
------ ------ ------ ------ ------
50 Hz 967 -965 -44.95 0.034
1 kHz 220 -213 -44 0.151
10 kHz 80 -58 -36 0.41
100 kHz 56 -9.3 -9.5 0.59
1 MHz 52.4 -2.4 -2.7 0.63
10 MHz 50.7 -0.76 -0.86 0.65
100 MHz 50.2 -0.23 -0.27 0.66

Smith Chart calculations begin to be inaccurate around 2 MHz and
below. So
do SWR meters.