View Single Post
  #244   Report Post  
Old April 20th 07, 05:47 AM posted to rec.radio.amateur.antenna
Cecil Moore[_2_] Cecil Moore[_2_] is offline
external usenet poster
 
First recorded activity by RadioBanter: Mar 2007
Posts: 3,521
Default Analyzing Stub Matching with Reflection Coefficients

Gene Fuller wrote:
I am familiar with all sorts of weird and wonderful things that happen
on surfaces and really close to interfaces and discontinuities.


Here's a little brain teaser for you, Gene.

Given the following experiment with two signal generators
equipped with circulators and load resistors - the generators
are phased-locked to ensure coherency. The two feedlines
are of equal electrical lengths.

100W | 25W
50 ohm---50 ohm line---+---291.4 ohm line---291.4 ohm
SGCL1 Pfor1=100W-- | --Prev2=25W SGCL2
--Prev1 | Pfor2--

What is the magnitude of Prev1? Pfor2?
--
73, Cecil http://www.w5dxp.com