Rohn 25G without guys, how high?
On Sun, 01 Jul 2007 20:44:45 +0000, Dave wrote:
to quote the book 'pinned bases must not be used'. think about it, when
there are no guys the highest stress point is where the metal meets the
concrete. each leg must be held down by something at least as strong as
it is.
Yup, makes sense.
Unfortunately the base is spaced out just a bit too far from the house to
be able to add a house brace that's strong enough. Why Dad did that I
can't quite figure out... of course, he had the mast at the time...
Also unfortunately, US Towers tells me that the bolt spacing on my base,
which was for a mast that was manufactured by a company that US Towers
apparently acquired years ago, is wrong for their current crop of crank-up
masts. :-( :-(
So, I guess I have a tower base that would hold up a (proper)
self-supporting tower through a hurricane, but I can't do anything with it. :-(
|