Yaesu FT-212 S meter question
I would hook it up to a signal generator with a calibrated attenuator first,
just to make sure that you don't have a blown front end device. Also, you
will be able to see how many microvolts are required to "move the meter".
You should be able to easily hear a 0.1uV signal from the generator.
Pete
"Craig" wrote in message
ups.com...
I recently bought a used Yaesu FT-212RH, in very good condition,
everything seems to work fine.
Though the S-meter is a somewhat odd or very, very stingy.
When talking to people simplex, the s-meter (bars) either dont show
any signal strength at all or very little, even when the simplex
station is strong. When listening to repeaters the s-meter bar lights
show up in varying signal strengths, so I know the S-meter does work.
Does someone have a service manual or know how to adjust this S-
meter.
Thank You
|