View Single Post
  #133   Report Post  
Old December 15th 07, 05:03 AM posted to rec.radio.amateur.antenna
John Smith John Smith is offline
external usenet poster
 
First recorded activity by RadioBanter: Nov 2006
Posts: 2,915
Default Standing Wave Phase

Cecil Moore wrote:

---43.4 deg 600 ohm line---+---10 deg 100 ohm line---open

---43.4 deg 300 ohm line---+---10 deg 50 ohm line---open

So how long does the 600 ohm line have to be in the following
example for the stub to exhibit 1/4WL of electrical length?

---??? deg 600 ohm line---+---10 deg 50 ohm line---open


Strange, for the 600/100/10 degree I get:

Arctan(100\600)*(1/tan(10)) = 53.6635

for 300/50/10 degree:

Arctan(50\300)*(1/tan(10)) = 53.6635

and for 600/50/10 degree:

Arctan(50\600)*(1/tan(10)) = 27.0160

What am I missing here?

Arctan(50\600)*(tan(80)) still equ 27.0160

Don't tell me the calc is on the fritz!

Regards,
JS