On Jan 2, 10:01*pm, (Scott Dorsey) wrote:
Graham wrote:
Ok thanks for the link , thats very close , this is from a *skanti
400 w ssb tx , but as its no longer in production, the makers are not
'helping' * looks like the easey way may be to *use a 500mA microwave
oven fuse ... but i dont think that will be a 'quick blow' type of
fuse , the pa uses *qty *2 *4cx250-b in parallel and a big *400hz
invertor psu running from 24 v dc @ 45 amps for the whole set ...
Microwave oven fuses are on the transformer primary and are normally
intended for 250VAC maximum use. *3AG types will sustain an arc for a hell
of a long time with 1KVDC across them. *Remember, AC arcs will quench a
lot easier than DC.
Call Bussman and see what they can do for you.
--scott
--
"C'est un Nagra. *C'est suisse, et tres, tres precis."
oK , The fuse ive had to use in the past is 500mA @ 5 Kv , it would
be nicer to fit the original , even the microwave ones are not
cheap !
Ill try them in the moring - tnx - G ..