Thanks for the follow-up! Perhaps they used a voltage regulating
transformer. I think some of the telcom rectifiers used them.
I know some mainframe computers did.

It's still a curiosity to me. Though I've seen enough occult
behavior from wound magnetic devices that I wouldn't discount it,
I'm tempted to wonder if there's another variable that was
coincident with the welded laminations.

73



"Henry Kolesnik" wrote in
:

Grumpy
Years ago in 93 or so on a Telco fiber system by Alcatel we took severe
hits when the air conditioner came on and it was traced to the station
rectifier. The Gould rectifiers had a weld bead and when we replaced
them another make which I can't recall that didn't have weld beads the
problem went away. Its quite strange since the rectifiers floated big
batteries but a vco in system was sensitive to the spike. After doing
some research I found an explanation that I can't recall because I was
too busy with other problems and mine had gone away. Alcatel spent
several hundred thousand trying to find the problem and I stumbled on to
it by shear luck.

73
Hank WD5JFR