View Single Post
  #10   Report Post  
Old March 13th 09, 08:56 PM posted to rec.radio.amateur.boatanchors
Antonio Vernucci Antonio Vernucci is offline
external usenet poster
 
First recorded activity by RadioBanter: Jun 2006
Posts: 395
Default Paper capacitor and Hallicrafters S-40A notes

That might happen using a capacitance meter than does
not measure the series and parallel resistance. The GR
bridge does, which is not to say that you might not be
right.


Dick,

what I meant to say is the following:

At 1kHz, a 500 pF capacitor with a 500,000 ohm resistance in parallel is
equivalent to the series of of 702 pF capacitor and 144,200 ohm resistior
(using the well known parallel-to-seriel translation formulas).

So, if your meter has the ability to separately measure the series resistance
and capacitance, it should correctly indicate 702 pF, i.e. a value higher than
that marked on the capacitor.

73

Tony I0JX