View Single Post
  #1   Report Post  
Old May 15th 09, 07:48 AM posted to rec.radio.amateur.antenna
dykesc dykesc is offline
external usenet poster
 
First recorded activity by RadioBanter: Apr 2007
Posts: 53
Default Conjugate Match and Mismatch Attenuation

1. Does achieving a conjugate match via a transmatch between the
transmitter and line do anything to reduce or eliminate mismatch loss
in the line? In other words, if a line is 8:1 swr into a complex
impedance load are the 8:1 "mismatch" losses still occurring even
after achieving low swr with a transmatch?

2. (Unrelated to first question) After installation of a choke at the
antenna input, swr on my off center fed dipole is surprisingly flat
across the amateur bands, never rising much above 8:1 and this only on
the high end of 80 meters. Reading Maxwell's "Reflections" series, it
seems that this may be due to saturation of the choke at higher
frequencies and I may have introduced non negligible loss into my
antenna system. The choke was made by winding my RG-58 coax through a
3" toroid of unknown permeability (14 turns). Other than the toroid
being solid black, I can't tell you anymore about it. I am using an
MFJ-259B for measurements. It would seem to me the 259B would not be
capable of delivering enough power to saturate the large toroid so
maybe my "too flat" readings are occurring due to something else.

Any advice on the above much appreciated. Please include a comment on
the ability of the 259B to be affected by toroid saturation.