Thread
:
Feeding System found it = Mosley
View Single Post
#
3
May 13th 10, 08:59 AM posted to rec.radio.amateur.antenna
Owen Duffy
external usenet poster
First recorded activity by RadioBanter: Dec 2006
Posts: 1,169
Feeding System found it = Mosley
lu6etj wrote in news:90c5c494-45a0-476c-8f9e-
:
On 13 mayo, 02:11, Owen Duffy wrote:
lu6etj wrote in news:e57e2fbf-75a6-4014-a190-
:
Adding an ideal reactance of -155 ohms
Bit is not a fixed reactance, it is a transmission line element, and
you
should model it as that, even if lossless.
Owen
;=D Easy and quick 50 ohm transmission line 0.05121 lambda (-150
ohms) replacement for old fix reactance in the same segment = ¡Same
result...! and now... I'm go to ZZZZZ
If you specified it in wavelengths, wouldn't that have a constant
reactance.
The real stub is a fixed physical length, and its reactance changes with
frequency.
Owen
Reply With Quote
Owen Duffy
View Public Profile
Find all posts by Owen Duffy