"Michael A. Terrell" wrote in message ...
"G.Beat" wrote:

I also have the Weller Tech Sheet for this model -- if you need
a copy. This has part numbers, diagrams and troubleshooting advice (shipped
with every unit new)

Yes, I will consider repairing for you - but it would have to be after the
holidays.
Greg
Repairing the Weller WTCP series since 1975


I would like a copy of that, if you don't mind.


Bugger me - I'm glad you lot are not troubleshooting a nuclear power
station!
The Weller WTCP must be one of the simplest decent temperature
controlled irons on the market, mine runs 15hrs/day and does so year
in / year out. Sometimes more when I forget to turn it off - the new
ones dont have the neon in the mains switch so it does happen - I have
2 of them now, one on each bench...

Test procedure.

1. Runs continually, therefore base station and element OK.

2. Check switch - unscrew bit retainer and remove (iron off). Pull
tip in and out - should hear click if switch working. If not, then
switch or tip faulty.

3. LOOK at tip, see if mangnet thingo at bottom has fallen of - if so,
buy new tip (and after all the years youve had it, I wonder if it
could solder anything except 2 wires together, my tips last about 3
months on average, I buy them by the half dozen). If tip defective,
completely dismantle iron and remove magnet from switch assembly.

4. If tip OK (go on, be a devil, buy a new one anyway....) then switch
faulty. Buy new one.

5. Exception to item 4 - if you have done bugger all maintenance to
your iron, clean the garbage out of the barrel - it is rare for
switches to fail "on" (never had one do it, as a matter of fact, but
have only been using Wellers for 20 years so it COULD happen...) - use
a bamboo satay skewer to clean out the crap, then follow procedure 2.

Hope this helps,

de VK3BFA Andrew (at 50, an "official old grump")