On Fri, 19 Dec 2003, G.Beat wrote:
Wow, I didn't think that my question would generate so many responses!
Thanks everyone for your input.

The Red-Glow tells you 2 things:

1. The heater (Weller EC234) is still working (but you are shortening its
life operating in this manner - cherry red)


Well, I don't operate with it cherry red. This is the first time it's done
that--hence my knowing that something is amiss.

2. The WTCP series temperature control (which works with the "PT" tip and
the SW60 switch) is not working properly.


Recommend: Change tips. Improper tips will cause this problem.
Get a Weller PTA7 (which is the standard tip shipped with this iron).
The barrel net (BA-60 may also require replacement.


I'll take a look and see. The station came with two tips, both #7, but in
the 11-odd years I've owned the iron I've never used the second one.

I also have the Weller Tech Sheet for this model -- if you need
a copy. This has part numbers, diagrams and troubleshooting advice (shipped
with every unit new)


Actually, I would like a copy, thank you. Since I got mine at a yard sale
I don't have any documentation. Please e-mail to
, removing the reversed "nospam" first.

-Josh, AE6IQ