On Jun 16, 11:16*pm, Cecil Moore wrote:
On Jun 16, 6:04*pm, K1TTT wrote:

would you care to provide us with the general equation for A given a
complex load impedance and a line length other than a multiple of 90
degrees?


It's simply the relative phase angle between the forward voltage and
reflected voltage at the source resistor. I trust that you can manage
that without my help.
--
73, Cecil, w5dxp.com


ah, so you do have to calculate the voltages, which would requires two
transformations of the length of the coax plus calculating the
magnitude and angle of the complex reflection coefficient then adding
them all up. still sounds like more work than necessary.