View Single Post
  #88   Report Post  
Old April 17th 04, 08:05 PM
James Meyer
 
Posts: n/a
Default

On Sat, 17 Apr 2004 17:26:15 +0100, John Woodgate
posted this:

I read in sci.electronics.design that James Meyer
wrote (in ) about 'A neat
and compact way to generate RF harmonics...', on Sat, 17 Apr 2004:
IOW, the Q without the probe will be higher than the Q when you insert
the probe to measure the Q.


Use an inductive current pick-off. That how the Marconi Instruments 1245
series Q-meters work(ed).


Nevertheless, *ANY* method used to probe the field associated with the
resonator will load the resonator and degrade the Q.

Jim