Thread: Toriod winding
View Single Post
  #3   Report Post  
Old September 17th 04, 01:49 AM
David Duxbury
 
Posts: n/a
Default

Hi Scott I have tried and no way can i get 40 turns in without
overlapping, also is it correct to wind on only 80 percent of the core

Scott wrote:
Remember, each time the wire passes through the core is counted as a
turn. In other words, just passing the wire straight through the core
is one turn. 24 gauge wire should be fairly easy to get 40 turns in a
single pass. Toroids are usually wound about 330 degrees around (a 30
degree gap between start and end of winding)...

Scott


David Duxbury wrote:

Good day I am putting together a Vectronics 80 Meter Transceiver
Kit , the problem I have is winding the T50-2 toroid , the
instructions state to wind 40 turns of 24 gauge wire, would that be
two passes of twenty as forty on a single pass is nigh impossible.
Help would be appreciated.