200 (197 on my DVM) ohm termination:
R 155 S 051 Z 197 75 (74.5 on my DVM) ohm termination R 047 S102 Z 146 With the cap sweep, with two different caps (a 100pF doorknob and a 30pF air variable trimmer), R is almost never zero until I get up into the 60MHz+ range and even then, rarely. With the coax check, the SWR oscillation amplitude is about 0.2 or so; 1.1-1.3. R and X vary smoothly and more or less cyclically.. I guess the oscillatory SWR variation with frequency is incorrect... I do get more than you mentioned and more than one might expect... i've got about 40 feet of RG-55U terminated in the 74.5 ohm termination that I used above. - - - - - - From what you've said, it seems like alignment time. I guess the large resistive component on capacitors at low frequency is a numerical artifact of a slight misalignment... because the R S Z menu values are really fairly close to yours. I'll build or find some precise SMT terminations and go at it. Thanks much for your help and I'll post after I do the alignment. 73, Dan |