Home |
Search |
Today's Posts |
#10
![]() |
|||
|
|||
![]() "Massi" wrote in message . .. "Massi" ha scritto nel messaggio ... Thanks a lot for all the answers, I'm doing some tests in laboratory with a network analyzer and will let you know asap what I will find. Massimo I have done some tests with trasmission line builded in FR4 (30cm long, 2cm wide), according to them I have the following notes: VSWR MICROSTRIP 50 OHM 13.56 MHz = 1.0129 1 GHz = 1.0457 3 GHz = 1.0994 VSWR COPLANAR WAVEGUIDE 50 OHM 13.56 MHz = 1.0250 1 GHz = 1.1698 3 GHz = 1.3500 VSWR STRIPLINE 50 OHM 13.56 MHz = 1.0315 1 GHz = 1.0269 3 GHz = 1.2665 LOSS MICROSTRIP 50 OHM 13.56 MHz = - 0.03360 dB 1 GHz = - 0.83380 dB 3 GHz = - 2.40590 dB LOSS COPLANAR WAVEGUIDE 50 OHM 13.56 MHz = - 0.04660 dB 1 GHz = - 0.84300 dB 3 GHz = - 2.12640 dB LOSS STRIPLINE 50 OHM 13.56 MHz = - 0.06340 dB 1 GHz = - 1.00830 dB 3 GHz = - 3.05160 dB bye, Massimo Isn't waveguide kind of big at 13.56 MHz? John |