Standing Wave Phase
Tom Donaly wrote:
Cecil Moore wrote: I already did it on another thread, Tom. Adding 43 degrees of Z0=600 ohm feedline to the 10 degrees of Z0=100 ohm feedline will turn the stub into an electrical 1/4 wavelength (90 degree) open stub. And that's exactly how base-loaded mobile antennas work. It will, will it? I'm waiting for you to prove it. Do you really expect it to be resonant at the right frequency? I have proved it in a reply to Dan and verified it with MicroSmith. I don't know what else you are asking for. Yes, it will resonate at the design frequency. Are you incapable of those simple calculations? Note that everything is rounded off to the nearest degree. -- 73, Cecil http://www.w5dxp.com |
Standing Wave Phase
John Smith wrote:
You mean at the frequency where the 600 line length is 53 degrees and the 100 line 10 degrees length ... well, I guess that already answers your own question, doesn't it?--but then, you should have already knew that ... Make that 43 degrees instead of 53 degrees. -- 73, Cecil http://www.w5dxp.com |
Standing Wave Phase
Tom Donaly wrote:
O.K., Cecil, I finally figured out what you want to do. You want a zero ohm input impedance, just like a 1/4 wave open stub. In that case, you're absolutely right, the 600 ohm line should be 43.387 degrees long. If you call the 100 ohm line, line 1, and the 600 ohm line, line 2, then the criterion for what you want is: tan(Bl1)*tan(Bl2)= Z01/Z02. This behaves sort of like a backwards, transmission-line, Helmholtz resonator. I still don't know where you come up with the 90 degree stuff. For an open stub to exhibit a zero ohm input impedance, it must be electrically 90 degrees long (or 270 ...). That's where the 90 degrees comes from. The example stub is electrically 90 degrees long while being 53 degrees long physically. Good for you, Tom, now you have it - "just like a 1/4WL open stub" from 53 degrees of transmission line. Here's another tidbit for you. Using 600 ohm line and 100 ohms line, if you make the two sections equal length, the dual-Z0 stub will be very close to 1/2 the physical length of a single-Z0 stub, i.e. physically 45 degrees long for an electrical 1/4WL (90 deg) stub. On 75m, that cuts the 1/4 stub physical length from ~66 feet to ~33 feet, a much more manageable length. Here's a useful equation. For a 1/4WL stub with equal length sections, the physical length in degrees of each section is: ARCTAN[SQRT(Z0Low/Z0High)] -- 73, Cecil http://www.w5dxp.com |
Standing Wave Phase
"Cecil Moore" wrote in message t... Tom Donaly wrote: O.K., Cecil, I finally figured out what you want to do. You want snip Using 600 ohm line and 100 ohms line, if you make the two sections equal length, the dual-Z0 stub will be very close to 1/2 the physical length of a single-Z0 stub, i.e. physically 45 degrees long for an electrical 1/4WL (90 deg) stub. On 75m, that cuts the 1/4 stub physical length from ~66 feet to ~33 feet, a much more manageable length. Here's a useful equation. For a 1/4WL stub with equal length sections, the physical length in degrees of each section is: ARCTAN[SQRT(Z0Low/Z0High)] -- 73, Cecil http://www.w5dxp.com lurking off NEAT lurking back on |
Standing Wave Phase
Cecil Moore wrote:
... Make that 43 degrees instead of 53 degrees. Sorry, don't know if that is brain atrophy from age or the 20mg hydrocodone the doc has me on for the fractured bone and arthritis in the spine--laying down a bike at ~60mph is something better left for the younger generation. Can't seem to find my glasses after I lay 'em down--wife claims she has already given me something, I claim no, then find 'em in my pocket. By the way, one week in the hospital cost: Hospital $80,000, emergency room $1,900, ambulance $1 |
Standing Wave Phase
John Smith wrote:
Cecil Moore wrote: ... Make that 43 degrees instead of 53 degrees. Sorry, don't know if that is brain atrophy from age or the 20mg hydrocodone the doc has me on for the fractured bone and arthritis in the spine--laying down a bike at ~60mph is something better left for the younger generation. Can't seem to find my glasses after I lay 'em down--wife claims she has already given me something, I claim no, then find 'em in my pocket. By the way, one week in the hospital cost: Hospital $80,000, emergency room $1,900, ambulance $1,500, etc. Oh yeah, and then there is constantly hitting the wrong key and sending email early ... Sorry guys/gals ... keep your medical PAID UP! Regards, JS |
Standing Wave Phase
Cecil Moore wrote:
Tom Donaly wrote: O.K., Cecil, I finally figured out what you want to do. You want a zero ohm input impedance, just like a 1/4 wave open stub. In that case, you're absolutely right, the 600 ohm line should be 43.387 degrees long. If you call the 100 ohm line, line 1, and the 600 ohm line, line 2, then the criterion for what you want is: tan(Bl1)*tan(Bl2)= Z01/Z02. This behaves sort of like a backwards, transmission-line, Helmholtz resonator. I still don't know where you come up with the 90 degree stuff. For an open stub to exhibit a zero ohm input impedance, it must be electrically 90 degrees long (or 270 ...). That's where the 90 degrees comes from. The example stub is electrically 90 degrees long while being 53 degrees long physically. (The rest deleted.) O.k., Cecil, you said it, now prove it. There's no requirement for a 90 degree phase shift when you do the math. Don't expect me to do it for you this time. Since I did some math for you, you can do some for me: Given the above formula, if you know l1, l2, and Z01, and Z02, what's the formula for B? It should be easy, right? 73, Tom Donaly, KA6RUH |
Standing Wave Phase
Cecil Moore wrote:
John Smith wrote: You mean at the frequency where the 600 line length is 53 degrees and the 100 line 10 degrees length ... well, I guess that already answers your own question, doesn't it?--but then, you should have already knew that ... Make that 43 degrees instead of 53 degrees. Some, like me, might like to review some info like this, easily digest-able ...: http://courses.ece.uiuc.edu/ece450/N...sionLines2.pdf Regards, JS |
Standing Wave Phase
John Smith wrote:
By the way, one week in the hospital cost: Hospital $80,000, emergency room $1,900, ambulance $1 I'm sorry that happened. Get well quick. -- 73, Cecil http://www.w5dxp.com |
Standing Wave Phase
Tom Donaly wrote:
O.k., Cecil, you said it, now prove it. There's no requirement for a 90 degree phase shift when you do the math. Are you using the equation for forward and reflected current? If not, you need to do so. The phase shift is not in the standing-wave current. Standing-wave current phase is fixed with respect to the source. Absolutely *nothing* happens to the standing-wave current at the impedance discontinuity. The reflected current is known to be in phase with the forward current at the feedpoint. The forward current is reflected at the tip of the antenna and undergoes a 180 degree phase shift. Something must account for the other 180 degrees or else the feedpoint impedance would not be resistive. I am working on a graphic that illustrates what happens at the impedance discontinuity. Please enlighten us on how the reflected current gets back in phase with the forward current without undergoing a phase shift of 180 degrees in its round-trip path. It is my understanding that the forward phasor rotates in one direction while the reflected phasor rotates in the opposite direction. The key concept there is that a phasor is always rotating. I have waded through the math before but I cannot locate my notes after moving. If you can figure out a reasonable answer to the above question, I will certainly consider it. -- 73, Cecil http://www.w5dxp.com |
Standing Wave Phase
Cecil Moore wrote:
Gene Fuller wrote: But you already knew that . . Of course I did. "Through the coil" does NOT mean "through the coil wire". It means "through the coil". You still uttered a falsehood but I doubt that you will ever admit it. Cecil, You got me. I omitted the word "wire". Of course your time delay "impossibility" complaint makes absolutely no sense at all if you accept that W8JI was not talking about a wave traveling through 50 feet of wire in 3 ns. He was talking about a wave traveling 10 inches in 3 ns. I mistakenly assumed that no one in this discussion even remotely considered superluminal wave propagation. Please accept my humble apology for an utter lack of fine craftsmanship in word games. 73, Gene W4SZ |
Standing Wave Phase
Cecil Moore wrote:
Tom Donaly wrote: O.k., Cecil, you said it, now prove it. There's no requirement for a 90 degree phase shift when you do the math. Are you using the equation for forward and reflected current? If not, you need to do so. The phase shift is not in the standing-wave current. Standing-wave current phase is fixed with respect to the source. Absolutely *nothing* happens to the standing-wave current at the impedance discontinuity. The reflected current is known to be in phase with the forward current at the feedpoint. The forward current is reflected at the tip of the antenna and undergoes a 180 degree phase shift. Something must account for the other 180 degrees or else the feedpoint impedance would not be resistive. I am working on a graphic that illustrates what happens at the impedance discontinuity. Please enlighten us on how the reflected current gets back in phase with the forward current without undergoing a phase shift of 180 degrees in its round-trip path. It is my understanding that the forward phasor rotates in one direction while the reflected phasor rotates in the opposite direction. The key concept there is that a phasor is always rotating. I have waded through the math before but I cannot locate my notes after moving. If you can figure out a reasonable answer to the above question, I will certainly consider it. How about answering the other part of my post, Cecil. I didn't use reflection mechanics to reach my conclusion. I did use two port ABCD parameters (the hard way) which can be derived from reflection mechanics. Anyway, you're being too simple. If you're going to use reflection mechanics, you have to account for all the reflections, and you have to explain yourself each step of the way. Anyway, destroy a few brain cells thinking about the other part of my post and get back to me. 73, Tom Donaly, KA6RUH |
Standing Wave Phase
Cecil Moore wrote:
John Smith wrote: By the way, one week in the hospital cost: Hospital $80,000, emergency room $1,900, ambulance $1 I'm sorry that happened. Get well quick. Off topic, I know you have a harley though ... Had putts since I was 16, never had an accident out of the dirt, nothing ever serious, etc. Be careful on that monster of yours--wishing ya all the luck--and, oh yeah, TAKE CARE on that road! They ARE out to get ya ... ;-) Regards, JS |
Standing Wave Phase
Gene Fuller wrote:
Cecil Moore wrote: "Through the coil" does NOT mean "through the coil wire". It means "through the coil". You still uttered a falsehood but I doubt that you will ever admit it. You got me. I omitted the word "wire". In that case, I apologize for jumping on you. The VF of the coil is approximately double what it would be if the current followed the wire. That's because of the inter-winding interaction. But the magnetic fields from coil#1 do not magically jump 10 inches to coil#100 as W8JI implies they do. His measurements are off by a magnitude because he used standing-wave current for his measurements. I suspect he actually measured less than 3 ns "delay" but knew he couldn't afford to post a faster-than-light measurement. -- 73, Cecil http://www.w5dxp.com |
Standing Wave Phase
Tom Donaly wrote:
If you're going to use reflection mechanics, you have to account for all the reflections, and you have to explain yourself each step of the way. I can do that, Tom, but I am standing by for an emergency trip to New York which involves my daughter's life. In the meantime, let's see if we can agree if 43.4 degrees of 600 ohm line is terminated in -j567 ohms, the forward current will be in phase with the reflected current, i.e. the impedance looking into the line will be zero ohms. Have you used any current reflection coefficients recently? :-) -- 73, Cecil http://www.w5dxp.com |
Standing Wave Phase
Cecil Moore wrote:
Tom Donaly wrote: If you're going to use reflection mechanics, you have to account for all the reflections, and you have to explain yourself each step of the way. I can do that, Tom, but I am standing by for an emergency trip to New York which involves my daughter's life. In the meantime, let's see if we can agree if 43.4 degrees of 600 ohm line is terminated in -j567 ohms, the forward current will be in phase with the reflected current, i.e. the impedance looking into the line will be zero ohms. Have you used any current reflection coefficients recently? :-) Actually, I have. They're built into the formulas for transmission line voltages and currents on my calculator. My calculator is a Cecil disciple. I hope your daughter comes through in good shape. I understand the worry, believe me. 73, Tom Donaly, KA6RUH |
Standing Wave Phase
Cecil Moore wrote:
... I am standing by for an emergency trip to New York which involves my daughter's life. ... Prayers and best wishes ... God protect and speed. Warmest regards, JS |
Standing Wave Phase
Tom Donaly wrote:
Cecil Moore wrote: In the meantime, let's see if we can agree if 43.4 degrees of 600 ohm line is terminated in -j567 ohms, the forward current will be in phase with the reflected current, i.e. the impedance looking into the line will be zero ohms. Have you used any current reflection coefficients recently? :-) Actually, I have. They're built into the formulas for transmission line voltages and currents on my calculator. So are we agreed that a 43.4 degree stub terminated in 0-j567 ohms impedance is electrically 1/4WL, i.e. 90 degrees long? -- 73, Cecil http://www.w5dxp.com |
Standing Wave Phase
Cecil Moore wrote:
Tom Donaly wrote: Cecil Moore wrote: In the meantime, let's see if we can agree if 43.4 degrees of 600 ohm line is terminated in -j567 ohms, the forward current will be in phase with the reflected current, i.e. the impedance looking into the line will be zero ohms. Have you used any current reflection coefficients recently? :-) Actually, I have. They're built into the formulas for transmission line voltages and currents on my calculator. So are we agreed that a 43.4 degree stub terminated in 0-j567 ohms impedance is electrically 1/4WL, i.e. 90 degrees long? No, but I agree with myself that whatever voltage is applied to the input will be canceled by all the reflections in the circuit adding up to a voltage at said input that will cancel the input voltage. It's like finding the zeros of a network equation. 73, Tom Donaly, KA6RUH |
Standing Wave Phase
On Dec 6, 9:48 pm, Cecil Moore wrote:
So are we agreed that a 43.4 degree stub terminated in 0-j567 ohms impedance is electrically 1/4WL, i.e. 90 degrees long? There are many ways to get the 0 input impedance: - 43.4 degrees of 600 ohm line terminated in a lumped 0-j567 impedance (assuming I recall the problem corrrectly and you did the math correctly) - 43.4 degrees of 600 ohm line followed by 46.6 degrees of 600 ohm line, open at the end - 43.4 degrees of 600 ohm line followed by 10 degrees (IIRC) of 100 ohm line, open at the end - a short - 180 degrees of any impedance line shorted at the end - and many, many more Are you claiming that all of these are electrically 1/4WL ? Even the 180 degree line? And the short? Seems like a stretch. And when looked at in detail (think time domain for moment), they each behave quite differently. ....Keith |
Standing Wave Phase
Keith Dysart wrote:
On Dec 6, 9:48 pm, Cecil Moore wrote: So are we agreed that a 43.4 degree stub terminated in 0-j567 ohms impedance is electrically 1/4WL, i.e. 90 degrees long? There are many ways to get the 0 input impedance: (1)- 43.4 degrees of 600 ohm line terminated in a lumped 0-j567 impedance (assuming I recall the problem corrrectly and you did the math correctly) (2)- 43.4 degrees of 600 ohm line followed by 46.6 degrees of 600 ohm line, open at the end (3)- 43.4 degrees of 600 ohm line followed by 10 degrees (IIRC) of 100 ohm line, open at the end (4)- a short (5)- 180 degrees of any impedance line shorted at the end - and many, many more If you calculate the complex rho and calculate the phase shift provided by a -j567 impedance, you will agree with my statement above. Are you claiming that all of these are electrically 1/4WL ? Of course not!!!! I numbered your examples above. Examples 1-3 are electrically 1/4WL long. Example 4 is 0 WL long. Example 5 is 1/2WL long. All my remarks apply only to stubs and antennas that are electrically 1/4WL long. My remarks do NOT apply to any stub or antenna that is not electrically 1/4WL long. An ideal open stub that is 3/4WL long has the same impedance as a 1/4WL stub but is it obviously not 1/4WL long. -- 73, Cecil http://www.w5dxp.com |
Standing Wave Phase
On Dec 7, 12:37 pm, Cecil Moore wrote:
Keith Dysart wrote: On Dec 6, 9:48 pm, Cecil Moore wrote: So are we agreed that a 43.4 degree stub terminated in 0-j567 ohms impedance is electrically 1/4WL, i.e. 90 degrees long? There are many ways to get the 0 input impedance: (1)- 43.4 degrees of 600 ohm line terminated in a lumped 0-j567 impedance (assuming I recall the problem corrrectly and you did the math correctly) (2)- 43.4 degrees of 600 ohm line followed by 46.6 degrees of 600 ohm line, open at the end (3)- 43.4 degrees of 600 ohm line followed by 10 degrees (IIRC) of 100 ohm line, open at the end (4)- a short (5)- 180 degrees of any impedance line shorted at the end - and many, many more If you calculate the complex rho and calculate the phase shift provided by a -j567 impedance, you will agree with my statement above. Are you claiming that all of these are electrically 1/4WL ? Of course not!!!! I numbered your examples above. Examples 1-3 are electrically 1/4WL long. Example 4 is 0 WL long. Example 5 is 1/2WL long. All my remarks apply only to stubs and antennas that are electrically 1/4WL long. My remarks do NOT apply to any stub or antenna that is not electrically 1/4WL long. An ideal open stub that is 3/4WL long has the same impedance as a 1/4WL stub but is it obviously not 1/4WL long. Your original claim was that 43.4 degrees of 600 ohm line terminated with 0-j567 was electricall 90 degrees long. You made no reference to how the 0-j567 was obtained. You have said that 1, 2 and 3 from above are electically 90 degrees. How about: (6) 43.4 degrees of 600 ohm line, 180 degrees of arbitrary line terminated in a lump of 0-j567. This is just another way of placing 0-j567 at the end of the 43.4 degrees of 600 ohm line. And (5), if we use 600 ohm line is also 43.4 degrees of 600 ohm line terminated with 0-j567, this being obtained with 136.6 degrees of 600 ohm line that is short circuited. So while I can accept your statement , "My remarks do NOT apply to any stub or antenna that is not electrically 1/4WL long.", I am having great difficulty coming up for a rule so that I will know when your remarks apply. Can you provide a rule for discerning when a stub or antenna is electrically 1/4WL long? ....Keith |
Standing Wave Phase
Keith Dysart wrote:
You have said that 1, 2 and 3 from above are electically 90 degrees. How about: (6) 43.4 degrees of 600 ohm line, 180 degrees of arbitrary line terminated in a lump of 0-j567. This is just another way of placing 0-j567 at the end of the 43.4 degrees of 600 ohm line. Of course, if you add 180 degrees you have added 180 degrees to whatever existed before. Do you disagree? Can you provide a rule for discerning when a stub or antenna is electrically 1/4WL long? Of course! When the reflected wave undergoes a phase shift of 180 degrees in its round trip to the end of the stub and back, the stub is electrically 1/4WL long. How can you disagree with that? -- 73, Cecil http://www.w5dxp.com |
Standing Wave Phase
On Dec 7, 4:21 pm, Cecil Moore wrote:
Keith Dysart wrote: You have said that 1, 2 and 3 from above are electically 90 degrees. How about: (6) 43.4 degrees of 600 ohm line, 180 degrees of arbitrary line terminated in a lump of 0-j567. This is just another way of placing 0-j567 at the end of the 43.4 degrees of 600 ohm line. Of course, if you add 180 degrees you have added 180 degrees to whatever existed before. Do you disagree? So this meets the criteria you originally proposed and is an example of 90 degree electical length? Can you provide a rule for discerning when a stub or antenna is electrically 1/4WL long? Of course! When the reflected wave undergoes a phase shift of 180 degrees in its round trip to the end of the stub and back, the stub is electrically 1/4WL long. How can you disagree with that? So (4), a short, meets this criteria. It did not have to go far down the stub, but it did arrive back with a 180 degree phase change. But previously, you did not include (4). Is it now in the list? ....Keith |
Standing Wave Phase
Keith Dysart wrote:
Cecil Moore wrote: Keith Dysart wrote: Of course, if you add 180 degrees you have added 180 degrees to whatever existed before. Do you disagree? So this meets the criteria you originally proposed and is an example of 90 degree electical length? Don't be silly. 180 degrees plus any positive angle is more than 180 degrees. The context was mobile loaded antennas shorter than a physical 1/4WL. -- 73, Cecil http://www.w5dxp.com |
Standing Wave Phase
On Dec 8, 12:43 am, Cecil Moore wrote:
Keith Dysart wrote: Cecil Moore wrote: Keith Dysart wrote: Of course, if you add 180 degrees you have added 180 degrees to whatever existed before. Do you disagree? So this meets the criteria you originally proposed and is an example of 90 degree electical length? Don't be silly. 180 degrees plus any positive angle is more than 180 degrees. The context was mobile loaded antennas shorter than a physical 1/4WL. Hmmmm. So you are no longer in agreement with your original question: "So are we agreed that a 43.4 degree stub terminated in 0-j567 ohms impedance is electrically 1/4WL, i.e. 90 degrees long?" This is good. You can now understand why some were not quick to jump to agreement. The concept of electrical/physical degrees is an occasionally useful way to think about delay on a transmission line that is used in a single frequency environment. It even helps understand stubs where the reflection arrives back with some phase shift from the original. But extending the concept to lumped circuits or expecting to find 90 degrees when different impedances are involved has little value. It leads to worthless questions like "where did the missing degrees go?" This is much like ascribing excessive reality to "reflected power" which leads to worthless questions like "where did the reflected power go?". Or asking "where is the missing dollar?'. The flawed underpinnings lead to worthless questions. Well maybe not worthless, like the hotel puzzle, they test the ability of the answerer to detect flawed assumptions. ....Keith |
Standing Wave Phase
Keith Dysart wrote:
On Dec 8, 12:43 am, Cecil Moore wrote: Keith Dysart wrote: Cecil Moore wrote: Keith Dysart wrote: Of course, if you add 180 degrees you have added 180 degrees to whatever existed before. Do you disagree? So this meets the criteria you originally proposed and is an example of 90 degree electical length? Don't be silly. 180 degrees plus any positive angle is more than 180 degrees. The context was mobile loaded antennas shorter than a physical 1/4WL. Hmmmm. So you are no longer in agreement with your original question: "So are we agreed that a 43.4 degree stub terminated in 0-j567 ohms impedance is electrically 1/4WL, i.e. 90 degrees long?" Now I understand your confusion. I was talking about a -j567 ohm *capacitor*, not a virtual impedance. I was, of course, using the "impedor" definition of impedance but since that confused you, let me restate the question: "So are we agree that a 43.4 degree stub terminated in a -j567 ohm impedor is electrically 1/4WL, i.e. 90 degrees long?" This was the original meaning of the question. I'm sorry that you took it the wrong way and wasted so many postings on such a trivial misunderstanding. It leads to worthless questions like "where did the missing degrees go?" Click on "Load Dat" in the EZNEC model below. There are *no* missing degrees. All necessary degrees are present and accounted for. But you will never see them if you are trying to use standing-wave current to see them. http://www.w5dxp.com/coil512.ez This is much like ascribing excessive reality to "reflected power" which leads to worthless questions like "where did the reflected power go?". Since energy must be conserved, the proper question is: "Where did the reflected wave *energy* go?" Do you even know the answer? The answer is that there is exactly the amount of energy existing in a transmission line to support the forward wave and the reflected wave. -- 73, Cecil http://www.w5dxp.com |
Standing Wave Phase
On Dec 8, 9:18 am, Cecil Moore wrote:
Keith Dysart wrote: On Dec 8, 12:43 am, Cecil Moore wrote: Keith Dysart wrote: Cecil Moore wrote: Keith Dysart wrote: Of course, if you add 180 degrees you have added 180 degrees to whatever existed before. Do you disagree? So this meets the criteria you originally proposed and is an example of 90 degree electical length? Don't be silly. 180 degrees plus any positive angle is more than 180 degrees. The context was mobile loaded antennas shorter than a physical 1/4WL. Hmmmm. So you are no longer in agreement with your original question: "So are we agreed that a 43.4 degree stub terminated in 0-j567 ohms impedance is electrically 1/4WL, i.e. 90 degrees long?" Now I understand your confusion. I was talking about a -j567 ohm *capacitor*, not a virtual impedance. I was, of course, using the "impedor" definition of impedance but since that confused you, let me restate the question: "So are we agree that a 43.4 degree stub terminated in a -j567 ohm impedor is electrically 1/4WL, i.e. 90 degrees long?" This was the original meaning of the question. I'm sorry that you took it the wrong way and wasted so many postings on such a trivial misunderstanding. So does this new question rule out the cases (previously accepted) where the 0-j567 is obtained with 46.4 degrees of 600 ohm line or 10 degrees of 100 ohm line? These are not lumped capacitors. Some consistency that persists longer than one post would be valuable. ....Keith |
Standing Wave Phase
Keith Dysart wrote:
So does this new question rule out the cases (previously accepted) where the 0-j567 is obtained with 46.4 degrees of 600 ohm line or 10 degrees of 100 ohm line? These are not lumped capacitors. No, but they are an electrical 1/4WL, not any other length. The electrical length of a stub is whatever it is. If it is not 1/4WL, it is some other length. Why is that difficult to understand? -- 73, Cecil http://www.w5dxp.com |
Standing Wave Phase
On Dec 8, 5:59 pm, Cecil Moore wrote:
Keith Dysart wrote: So does this new question rule out the cases (previously accepted) where the 0-j567 is obtained with 46.4 degrees of 600 ohm line or 10 degrees of 100 ohm line? These are not lumped capacitors. No, but they are an electrical 1/4WL, not any other length. The electrical length of a stub is whatever it is. If it is not 1/4WL, it is some other length. Why is that difficult to understand? Well, I know what I mean by 1/4WL and in my definition there is no way that (46.4 + 10) = 90. However I am trying to help you articulate your definition in a way that is sufficiently precise that I can use it to determine what you would consider to be 1/4WL. Unfortunately, at the moment, it is sufficiently fuzzy that the only way to determine if something is 90 degrees (according to your definition) is to ask you. The need of an oracle to answer such questions is not the basis for sound science. Tautologies such as "If it is not 1/4WL, it is some other length." do not further the definition, but are good if you want to keep the job of oracle. ....Keith |
Standing Wave Phase
Keith Dysart wrote:
Well, I know what I mean by 1/4WL and in my definition there is no way that (46.4 + 10) = 90. Of course, those are *physical* degrees. We are talking about *electrical* degrees. It is impossible to get the reflected wave in phase with the forward wave unless there is an electrical 90 degree phase shift. If you lay the 43.4 degrees out starting at Z=0 toward the load on the Smith Chart and lay the 10 degrees out starting at Z=infinity toward the source, you will observe the phase shift caused by the impedance discontinuity. ... the only way to determine if something is 90 degrees (according to your definition) is to ask you. All one has to do is plot it on a Smith Chart and the number of electrical degrees is obvious. If you don't know how to use a Smith Chart it might be time to learn how. -- 73, Cecil http://www.w5dxp.com |
Standing Wave Phase
On Dec 9, 12:21 am, Cecil Moore wrote:
Keith Dysart wrote: Well, I know what I mean by 1/4WL and in my definition there is no way that (46.4 + 10) = 90. Of course, those are *physical* degrees. Yes indeed. And they have the benefit of concreteness and they are easy to account. We are talking about *electrical* degrees. It is impossible to get the reflected wave in phase with the forward wave unless there is an electrical 90 degree phase shift. Except that I have offerred a number of examples which you, the oracle, have declared are not 90 "electrical degrees". If you lay the 43.4 degrees out starting at Z=0 toward the load on the Smith Chart and lay the 10 degrees out starting at Z=infinity toward the source, you will observe the phase shift caused by the impedance discontinuity. I, too, can subtract (43.4 + 10) from 90 and get a number. This does not, by itself, a useful proposition make. ... the only way to determine if something is 90 degrees (according to your definition) is to ask you. All one has to do is plot it on a Smith Chart and the number of electrical degrees is obvious. Please provide your algorithm in sufficient detail that I can test it against the various examples. So far, each time you have provided a rule, I have constructed examples according to the rule which the oracle has declared are not 90 "electrical degrees". Without a testable rule that successfully distinguishes those cases which are 90 "electrical degress" from those which are not, there is nothing. Having to ask the oracle does not suffice. And the Smith chart is insufficient. One of your examples began with "take the impedance of 0-j567 and plot it on the chart", which is okay, but it turned out that how that impedance was created is important. It had to be a capacitor (sometimes). No amount of Smith charting will reveal that detail. A testable rule, please... ....Keith |
Standing Wave Phase
Keith Dysart wrote:
Except that I have offerred a number of examples which you, the oracle, have declared are not 90 "electrical degrees". If it is 90 electrical degrees then it is 90 electrical degrees. If it is not 90 electrical degrees, it is not 90 electrical degrees. I don't know how to make it any clearer than that. I, too, can subtract (43.4 + 10) from 90 and get a number. This does not, by itself, a useful proposition make. It does if we know the reflected wave undergoes a 180 degree round-trip phase shift or else the reflected wave would not be in phase with the forward wave and therefore the feedpoint impedance would not be purely resistive. Please provide your algorithm in sufficient detail that I can test it against the various examples. It's the same as determining if an antenna is 0.5WL or 1.5WL or 2.5WL or 3.5WL or ... Do you also have a problem with that? If the phase shift end-to-end is 180 degrees, the device is 90 electrical degrees long. If the phase shift end-to-end is not 180 degrees, the device is not 90 electrical degrees long. So far, each time you have provided a rule, I have constructed examples according to the rule which the oracle has declared are not 90 "electrical degrees". I have provided no rule. Everything is common sense. If a dipole is 130 feet, it is 1/2WL on ~3.6 MHz. If the antenna is 403 feet long, it is 1.5WL on ~3.6 MHz. Why do you have a problem telling the difference between a 130 foot dipole and a 403 foot dipole? -- 73, Cecil http://www.w5dxp.com |
Standing Wave Phase
Cecil Moore wrote:
... It does if we know the reflected wave undergoes a 180 degree round-trip phase shift or else the reflected wave would not be in phase with the forward wave and therefore the feedpoint impedance would not be purely resistive. ... Or, to sum that up in a nut shell, "Does everyone here know we can reverse the leads on our SWR meter (input goes to output--output goes to input) and the fwd/ref switch will just work "backwards." (but, readings should remain the same.) Indeed, an excellent way to check homebuilt SWR bridges and make sure they are "balanced." Regards, JS |
Standing Wave Phase
On Dec 9, 3:27 pm, Cecil Moore wrote:
Keith Dysart wrote: Except that I have offerred a number of examples which you, the oracle, have declared are not 90 "electrical degrees". If it is 90 electrical degrees then it is 90 electrical degrees. If it is not 90 electrical degrees, it is not 90 electrical degrees. I don't know how to make it any clearer than that. I suspect you are correct there. I, too, can subtract (43.4 + 10) from 90 and get a number. This does not, by itself, a useful proposition make. It does if we know the reflected wave undergoes a 180 degree round-trip phase shift or else the reflected wave would not be in phase with the forward wave and therefore the feedpoint impedance would not be purely resistive. Please provide your algorithm in sufficient detail that I can test it against the various examples. It's the same as determining if an antenna is 0.5WL or 1.5WL or 2.5WL or 3.5WL or ... Do you also have a problem with that? I use a measuring tape for that, so there is no problem. But if I recall correctly, your definition of 90 degress is not amenable to the use of measuring tapes. If the phase shift end-to-end is 180 degrees, the device is 90 electrical degrees long. If the phase shift end-to-end is not 180 degrees, the device is not 90 electrical degrees long. So far, each time you have provided a rule, I have constructed examples according to the rule which the oracle has declared are not 90 "electrical degrees". I have provided no rule. Everything is common sense. Everyone thinks they are full of "common sense" and that few others are. Science is not advanced by claiming common sense. If you do not have articulatable rules, then you do not even have a hypothesis, much less a theory. If a dipole is 130 feet, it is 1/2WL on ~3.6 MHz. If the antenna is 403 feet long, it is 1.5WL on ~3.6 MHz. Why do you have a problem telling the difference between a 130 foot dipole and a 403 foot dipole? No problem. But I am allowed to use a measuring tape to answer that question. And if you wrote a rule using measuring tapes for this 90 degree stuff, I would have no trouble with it either. But if the best you can do is claim "common sense", you can be sure that my "common sense" will arrive at different answers than yours. ....Keith |
Standing Wave Phase
Keith Dysart wrote:
If you do not have articulatable rules, then you do not even have a hypothesis, much less a theory. The theory I support is the distributed network model. It was invented before you or I were born. I do not have to defend it. If you disagree with it, you have to prove it false. -- 73, Cecil http://www.w5dxp.com |
Standing Wave Phase
On Dec 9, 8:50 pm, Cecil Moore wrote:
Keith Dysart wrote: If you do not have articulatable rules, then you do not even have a hypothesis, much less a theory. The theory I support is the distributed network model. It was invented before you or I were born. I do not have to defend it. If you disagree with it, you have to prove it false. A truly intriguing riposte: completely devoid of technical content, fails to further the discussion in any way, and yet deeply revealing about the thought processes at work. ....Keith |
Standing Wave Phase
Keith Dysart wrote:
On Dec 9, 8:50 pm, Cecil Moore wrote: Keith Dysart wrote: If you do not have articulatable rules, then you do not even have a hypothesis, much less a theory. The theory I support is the distributed network model. It was invented before you or I were born. I do not have to defend it. If you disagree with it, you have to prove it false. A truly intriguing riposte: completely devoid of technical content, fails to further the discussion in any way, and yet deeply revealing about the thought processes at work. I'm disappointed in you, Keith. You appeared to be a reasonably intelligent person. Now that you have apparently performed my suggested experiment and know that I am right, you try to tuck your tail and run. I'm disapointed, but not surprised. -- 73, Cecil http://www.w5dxp.com |
Standing Wave Phase
On Dec 9, 10:14 pm, Cecil Moore wrote:
I'm disappointed in you, Keith. You appeared to be a reasonably intelligent person. Thank you. And I continue to be so. Now that you have apparently performed my suggested experiment There is no evidence that I have performed the experiment. The need for current probes probably means that I will not be doing so, though you never know. Rest assured that should I do so, results will be published. and know that I am right, you try to tuck your tail and run. Ahhh, your favourite accusation. You play the game of last man standing, and when everyone has left the field (in this case because you had nothing further technical to add), you convince yourself that it is because you must be right, and they must know it. I can't decide if this logic is more amusing or sad. Now if you want to recover, make some better attempts to write the rule. Look back through the posts for your sentences that begin with "Can we agree that", or some such. These were your attempts at a rule. Complete them to the point that we agree that they are self consistent and accurately convey your definition and we will have gotten somewhere. Your later attempts, which amount to "I know it when I see it", were not nearly as good as your earlier ones. ....Keith |
Standing Wave Phase
Keith Dysart wrote:
Now if you want to recover, make some better attempts to write the rule. Look back through the posts for your sentences that begin with "Can we agree that", or some such. These were your attempts at a rule. Complete them to the point that we agree that they are self consistent and accurately convey your definition and we will have gotten somewhere. What is it that you need a rule for? Is it the electrical length of a stub? The stub is electrically half as long as the phase shift undergone by the reflected wave during its round trip to the open or shorted end and back to the feedpoint. If that phase shift in a dual-Z0 stub is the same as the phase shift in a single-Z0 stub at the same frequency, the two stubs are the same electrical length at that frequency. -- 73, Cecil http://www.w5dxp.com |
All times are GMT +1. The time now is 02:17 PM. |
Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
RadioBanter.com