Home |
Search |
Today's Posts |
#11
![]() |
|||
|
|||
![]()
On Jul 2, 9:33 am, John Smith wrote:
K7ITM wrote: ... The only way to keep a wire--e.g., piece of coax--from being a radiator is to keep net current at zero. If there's no net current, you didn't need the wire anyway (at that frequency, at least). If it's a protective ground for mains frequency, it will probably still work for that purpose if you add ferrite for RF choking. K7ITM: I was hoping the rf/dc/ac could reach ground via a very low resistance/impedance to rf on the inner surface of the braid and the center conductor ... While it would be virtually impossible to reduce rf on the outer braid to absolute zero, I was hoping the choke would provide sufficient impedance to rf to where it became near negligible, at least for practical purposes. Regards, JS If there's a net RF current, there's a net RF current, and it will radiate. It matters not a whit whether you say the net is on the inside or the outside or distributed between them in any proportion. If you choke things so there's no net current, you may as well not have bothered putting the wire/coax/whatever in to begin with. Consider what the current on the inside of the outer conductor must be if the coax is acting as a transmission line, and consider where that current goes at the "top" end of the piece you suggest. To keep RF "out of the shack," put a Faraday cage around the shack and don't turn RF loose inside that cage. Then it doesn't matter (with respect to RF "in the shack") whether the Faraday cage is connected to "ground" or not. What exactly is "ground," anyway? Do you think it has magical properties? What ARE its properties? What does it do for you? |
#12
![]() |
|||
|
|||
![]()
K7ITM wrote:
... If there's a net RF current, there's a net RF current, and it will radiate. It matters not a whit whether you say the net is on the inside or the outside or distributed between them in any proportion. ... Really, then I can throw away the current choke on my coax to my 1/2 wave vertical then? I THINK NOT!!! And, I DON'T think there is rf on the outside of the coax shield--I DO think there is on the inside of the braid ... ... What exactly is "ground," anyway? Do you think it has magical properties? What ARE its properties? What does it do for you? Find an improperly grounded kw xmitter/liner whose case is hot with rf and running into a noticeable SWR, now touch a sharp corner of the case with your finger. Pay attention to the hissing noise(s), the flesh being vaporized into a white smoke, the characteristic white, deep penetrating, slow-to-heal rf burn(s) on your finger, etc. Now ground the case and touch the sharp corner--notice the lack of pain? Now, that you should get you started with what a ground is ... got anymore questions? Now, I can explain all that without having to bring magic into the argument--but hell, go ahead, give me your "magical" version if you would like ... Regards, JS |
#13
![]() |
|||
|
|||
![]()
On Jul 2, 3:07 pm, John Smith wrote:
K7ITM wrote: ... If there's a net RF current, there's a net RF current, and it will radiate. It matters not a whit whether you say the net is on the inside or the outside or distributed between them in any proportion. ... Really, then I can throw away the current choke on my coax to my 1/2 wave vertical then? I THINK NOT!!! And, I DON'T think there is rf on the outside of the coax shield--I DO think there is on the inside of the braid ... ....which is balanced by the RF on the center conductor. If it doesn't radiate, there's no net current; the center conductor current is equal in magnitude and opposite in phase to the current on the adjacent inside of the outer conductor. Why would you think that what you quoted above would imply that you could get rid of the choke on your transmission line, if you want to keep the line from having a net current and therefore radiating? It says just the opposite. But of course, you already knew that, didn't you? Sorry, rhetorical question. |
#14
![]() |
|||
|
|||
![]()
K7ITM wrote:
If there's a net RF current, there's a net RF current, and it will radiate. It matters not a whit whether you say the net is on the inside or the outside or distributed between them in any proportion. If you choke things so there's no net current, you may as well not have bothered putting the wire/coax/whatever in to begin with. Consider what the current on the inside of the outer conductor must be if the coax is acting as a transmission line, and consider where that current goes at the "top" end of the piece you suggest. To keep RF "out of the shack," put a Faraday cage around the shack and don't turn RF loose inside that cage. Then it doesn't matter (with respect to RF "in the shack") whether the Faraday cage is connected to "ground" or not. What exactly is "ground," anyway? Do you think it has magical properties? What ARE its properties? What does it do for you? Interesting ... suggesting that if an inductance/capacitance it added into the shield (or center conductor) and in series with such, so that the current voltages between the center conductor and braid are 90 degrees lagging/leading that a net current would be possible between the inside braid and the center conductor. But, still due to the choke on the outer braid--impossible there (well, vastly reduced.) Hmmm ... a name for it? Perhaps "Tuned Ground" or "Tunable Ground." grin Regards, JS |
#15
![]() |
|||
|
|||
![]()
K7ITM wrote:
... ...which is balanced by the RF on the center conductor. If it doesn't radiate, there's no net current; the center conductor current is equal in magnitude and opposite in phase to the current on the adjacent inside of the outer conductor. Why would you think that what you quoted above would imply that you could get rid of the choke on your transmission line, if you want to keep the line from having a net current and therefore radiating? It says just the opposite. But of course, you already knew that, didn't you? Sorry, rhetorical question. Actually, it took me awhile to put this together, your picture of "the ground" given in your text ... Basically, we are two blind men, you have the trunk of the elephant in hand, me the foot ... but now that I think about it, I remember what picture the trunk brought to my mind ... A radiating ground I have used before, my first exposure to one instance of it was like this: In college, living in a couple of rooms rented to me by an individual having a home near the campus, I resided on the third floor of an old victorian (and, keep in mind, building codes were rather sparse back then.) The plumbing had been "reworked" and sections of it replaced with pvc. The old steam radiators had, had their piping removed in the basement level. In despiration, I had to resort to a wire ran around the base boards of the rooms and "adjusted" for various freqs/bands. This ground DID, indeed, radiate. Indeed, the "fuzz" on the video signal of the tv sets proved this absolutely--at times. The am band on a radio was also, frequently, troubled by my signals/rfi. All the above, because the owner did not want "wires ran about." The "ground wire" I was proposing would attempt to function as a transmission line, and simply carry the signals to a suitable ground; Whether you made that a legitimate number of buried radials of suitable length, a wire ran above ground and through the bushes, a wire connecting a few ground rods, or a run to the pipe in the basement, etc., would be at the users discretion ... however, the "ground wire" would be made to NOT radiate, or radiate as little as possible ... that is "the ground" (but actually, a "grounding transmission line") I was proposing with the coax. Regards, JS |
#16
![]() |
|||
|
|||
![]()
John Smith wrote:
... the current voltages between the center conductor and braid are 90 degrees lagging/leading that a net current would be possible between the ... In the above, 90 = 180 ... just caught that ... JS |
#17
![]() |
|||
|
|||
![]()
Ron Walters wrote:
After reading several articles both on and off the WEB regarding a center fed antenna, only one article mentioned a recommended length for the feed line. There is a webpage that calculates the correct length of the feedline for an antenna: http://www.qsl.net/w4sat/howlong.htm My shack is located on the second floor of a new home, (24') #8 ground wire to 8' ground stake with a further connection to the common ground point for the power and the rebar in the pored walls and flooring of the basement, telephone and cable. I plan on additional ground rods around the property and at a new tower. In a new home so progress is on-going. The 1:1 current balum used to convert the 450 ohm balance line is external to the tuner, use about two feet of coax from the balum to the tuner. Antenna is cut for 80 meters and using about 60-70 ft of line to center of the antenna. Where the antenna lines leave the shack is about four 4 ft from the location inside of the rig and floor mounted PC. I use the antenna on all bands until such time I complete a new tower installation. I want to minimize stray RF around the shack since I rely on a PC and digital sound card as my primary source for ham enjoyment. I have already had some problems with a USB keyboard that I think may have been effected by RF when running over 50 watts on 20 meters only. One article recommended odd multiples of a wave length is desirable at the lowest operating frequency while other articles don't address this. Since you are using ladder line, you don't really want a hwole lot of extra length, since you'd have to figure out what to do with it. Ladder line doesn't like being wound up - note this is what I've been told, I never experimented myself. But it stands to reason. I am having no problem with a match using the tuner on all bands 80-6 meters. The setup should work well. The grounding system isn't ideal, but we work with what we have. Have used the center fed antenna since 1976 but always had the shack on the ground level and had a good and effective ground system short runs with feed lines around the 90 to 100ft in length. never had a RF problem or surge problem. I'm not clear. Do you have an RFI problem now? Seems as if your steup will work FB. - 73 de Mike N3LI - |
#18
![]() |
|||
|
|||
![]() "Michael Coslo" wrote in message ... Ron Walters wrote: After reading several articles both on and off the WEB regarding a center fed antenna, only one article mentioned a recommended length for the feed line. There is a webpage that calculates the correct length of the feedline for an antenna: http://www.qsl.net/w4sat/howlong.htm I love it, the perfect answer at the click of a button! |
#19
![]() |
|||
|
|||
![]()
Dave wrote:
... http://www.qsl.net/w4sat/howlong.htm I love it, the perfect answer at the click of a button! Well, I will never accuse you two of not having a highly developed sense of humor! (and, that calculator is actually HIGHLY ACCURATE--error factor less than .000000000000000000000000001% grin) At first I missed the importance of that URL, thanks for posting a reply to the original--I got a chance to use it. LOL! Warm regards, JS |
#20
![]() |
|||
|
|||
![]() "John Smith" wrote in message ... Dave wrote: ... http://www.qsl.net/w4sat/howlong.htm I love it, the perfect answer at the click of a button! Well, I will never accuse you two of not having a highly developed sense of humor! (and, that calculator is actually HIGHLY ACCURATE--error factor less than .000000000000000000000000001% grin) At first I missed the importance of that URL, thanks for posting a reply to the original--I got a chance to use it. LOL! Warm regards, JS my formula is a little more complicated than the web site though. i take the distance from the shack to the antenna, add in the width of the shack (assuming some day i'll move the radio that it connects to somewhere else), then add a couple feet more just for good measure. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Zo of two wire open line | Antenna | |||
OPEN WIRE LINE | Antenna | |||
Adding lengths to bare wire antenna? | Antenna | |||
WTB: 2" open wire spreaders | Equipment | |||
WTB: 2" open wire spreaders | Swap |