dykesc wrote in news:ad161de6-d48c-4ad5-80a0-
: ... Sounds like even with a conjugate match at the transmitter, I need to calculate total line losses based on SWR readings without the transmatch in the line. Well, that is an approximation based on a number of assumptions. If you don't know the assumptions, or cannot be sure that they apply, it is better to calculate the line loss based on the load impedance (or inference from the input impedance). See TLLC at http://www.vk1od.net/calc/tl/tllc.php , or TWLLC at http://www.vk1od.net/calc/tl/tllc.php . My article "Additional loss due to VSWR" at http://vk1od.net/blog/?p=316 canvasses the issue. Owen |