On May 10, 9:35 pm, walt wrote:
If you are so confident that the number is 88.8889%, please derive the conditions that yield that number. Ã = R(load) - R(source) / R(load) + R(source) SWR = (1 + |Ã|) / (1 - |Ã|) Power Accepted by the Load = Incident Power * (1 - Ã^2) For a 50 ohm source connected to a 100 ohm load: Ã = (100 - 50) / (100 + 50) = 50 / 150 = 0.333333... SWR = (1 + 0.333333) / (1 - 0.333333) = 1.333333 / 0.666666 = 2:1 Load Power = Incident Power * (1 - 0.333333^2) = Incident Power * 0.888889 (or 88.8889%) The answers are the same for a 50 ohm source with a 25 ohm load. RF |