Home |
Search |
Today's Posts |
#6
![]() |
|||
|
|||
![]() "Gary Schafer" wrote in message ... Hi John, Thanks for the info. Also thanks to Richard for the link to sphere. They told me that people that have replaced those diodes used 1N5711. They are schottky diodes. Sphere wants $3.00 each for them and digi key has them for 39 cents each. I drug my probes out that I hadn't looked at in several years. I did find my manual and it does have a schematic of the probes but gives no part numbers for the diodes or the FET. In looking at my probe boards one has diodes that have numbers 392 717. They are the input diodes. The other set at the FET input have numbers 393 717. I don't know if they are original or replaced. The other probe has diodes marked HP on them and color bands. The input ones have yellow, green, gray. The ones at the FET input have yellow, violet, blue. Don't know if original or replaced. The color bands you mention sound familiar to me. I think they may be matched pairs. I see the input capacitor on one probe has been replaced and the 100k resistor. I checked the diodes with a meter and they all seem to have proper forward drop (around .3 volts or so) and high reverse reading. Maybe they are not bad? The problem may be the FET? Yours May not be. I verified three of mine had reverse leakage. Haven't worked on the thing in years. Sure would like to get it going. See a.b.s.e., subject HP 8405 Probe Schematic. What is a.b.s.e. ? alt.binaries.schematics.electronic How did you check the FET to find out it was bad? With a DVM. The schematic shows an N-channel junction FET. It should read like a diode with the + lead on the gate and the - lead on the source. It should show open with the leads reversed. It should show open with the + lead on the drain and - lead on the source with the gate connected to source. Mine had reverse gate leakage. The sphere site has some HP house number cross references if you have some HP numbers. They're not available to me right now. Wonder how you found the FET part number 2N3379 ? The part number was stamped on the FET. I used a magnifying glass. Keep in mind that the FET may have been replaced by the previous owner. I have run across several people with 8405,s with bad probes. Would be nice to figure out how to get them going. Yes, it would. You do know that the little probe boards unplug from the probe body, right? If you have a working probe on a working meter, you could try repairing the broken probe and try it on the working meter. I'm going to do that as soon as I can get the time. To email me direct make address garyschafer. Thanks for your help Gary K4FMX And thank you for your help, too, Gary. Maybe together we can get something going eventually. John KD5YI |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
AEA Isoloop: Stepper Motor Repair | Antenna |