Owen Duffy wrote in news:Xns9F98507D98D82nonenowhere@
88.198.244.100: .... (I did consider at one stage extending TLLC to allow specification of mismatch in terms of Gamma, rectangular and polar, but no one ever asked for it and I thought it not in demand. The complication is that finding Z from Gamma needs to use the nominal Zo of the test equipment, not the actual Zo of the lossy transmission line. I usually use a spreadsheet to perform the calcs, Excel can handle complex numbers using the COMPLEX and IM* functions either in the Analysis Tookpak in earlier versions, or built in to the later versions.) Agilen't AppCad can be a convenient tool for one-off calcs. Nevertheless, there is value in see the results of measurement as you make them, it helps to minimise the chance of leaving the task with errored data. Owen |