Cecil Moore wrote in message ...
David J Windisch wrote: R-f transmission-line swr reduction by what ever means is, I think, akin to what the local power company accomplishes by hanging lumps of reactance across its a-c transmission lines, ie, reducing volt-amps-reactive, in its system. The sum of the loads on a power line is virtually always inductive so the power company adds capacitors where they are needed. That is akin to stubs on an RF transmission line. Guess how long a 1/8WL stub would be at 60 Hz. :-) Depends on the velocity factor of the line used to make the stub... Then there's the old trick of the synchronous condenser for power factor correction. 73 de Jim, N2EY |