Dr. Slick August 10th 03 01:49 AM

Length of Coax Affecting Incident Power to Meter?
 
Hey,

I've been getting different readings on my power meter that
depend on the length of coax that i use to the meter (into a
Cantenna).

This is a push-pull VHF 300 watt transmitter with a coax stub
harmonic filter on the output. My digital Daiwa will read about 310
watts incident power using a 4 foot RG-8X jumper coax (from filter to
meter), and about 240 watts using a 12 foot section of RG-8X!!?? VSWR
stays the same at about 1.4:1 .

There is the old ham wife's tale that you can tune your
transmitter for a better match if you adjust the legnth of your coax
to the antenna. And from a theoretical point of view, it _should_ be
only a tale, because if your antenna is not a perfect 50 Ohms, the
length of the coax should still not matter, because the constant VSWR
circles around the center of the Smith Chart have just that, the same
SWR independant of the wavelengths away from the antenna (assuming 50
Ohm transmission lines are used).

OTOH, the actual series equivalent complex impedance will be
alternating from inductive to capacitive, every 1/2 wavelength.
So perhaps this will tune/detune the amplifier?

Any non-bullsh** advice/explainations appreciated.


Dr. Slick

K9SQG August 10th 03 02:08 AM

With a non-resistive load, the length of the coax and placement of an
inexpensive (e.g. non-Bird) meter will cause different readings.

'Doc August 10th 03 02:29 AM



"Dr. Slick",
Sure, for the CB crowd, it's in increments of 3 feet.
'Doc

W5DXP August 10th 03 03:13 AM

Dr. Slick wrote:
This is a push-pull VHF 300 watt transmitter with a coax stub
harmonic filter on the output. My digital Daiwa will read about 310
watts incident power using a 4 foot RG-8X jumper coax (from filter to
meter), and about 240 watts using a 12 foot section of RG-8X!!?? VSWR
stays the same at about 1.4:1 .


Remember the maximum power transfer theorem? The transmitter probably works
better into some impedances than into others. With an SWR of 1.4:1, the
transmitter will see a resistance between 35.7 ohms and 70 ohms with a reactance
between zero and about plus or minus j15. Knowing the frequency and VF of the
RG-8X, you should be able to estimate the two impedances seen by the transmitter.
--
73, Cecil http://www.qsl.net/w5dxp



-----= Posted via Newsfeeds.Com, Uncensored Usenet News =-----
http://www.newsfeeds.com - The #1 Newsgroup Service in the World!
-----== Over 80,000 Newsgroups - 16 Different Servers! =-----

Dr. Slick August 10th 03 11:05 AM

"Tarmo Tammaru" wrote in message ...
You don't say what VHF frequency, but the Cantenna is probably unsuitable at
that frequency. Your amp is spec'd to put out 300W into 50 Ohms, not 35 or
70. It could put out more or less power into a different impedance. Your
best bet is to build a little L network right at the Cantenna, adjust it for
1:1 SWR, and then measure the power. Another approach would be to string all
the RG58 you own in series with the 8X.

Tam/WB2TT


Less than 150 MHz. Someone else suggested that i place the meter
right at the cantenna, to at least exclude the patch from meter to
dummy load.

Unfortunately, as i have mentioned before, the cantenna is not the
greatest 50 Ohms at anything above 10-20 MHz.

Slick

Dr. Slick August 10th 03 11:11 AM

W5DXP wrote in message ...

Remember the maximum power transfer theorem? The transmitter probably works
better into some impedances than into others. With an SWR of 1.4:1, the
transmitter will see a resistance between 35.7 ohms and 70 ohms with a reactance
between zero and about plus or minus j15. Knowing the frequency and VF of the
RG-8X, you should be able to estimate the two impedances seen by the transmitter.



Actually, i read off of my Smith Chart about +/- j20, but you are
close.

Anyhow, my point is that the ham "wife's tale" of adjusting the
coax length for lowest SWR may be truly just a tale.

However, in my case, the SWR doesn't change much, while the
INCIDENT power does!!! To me, this may be due to the fact that the PA
isn't 50 Ohms at the output (I'll bet not many really are), and so a
swing of +/- j20 may improve or degrade how close you are to a
conjugate match.

What do you dudes think?


Dr. Slick

W5DXP August 10th 03 12:51 PM

Dr. Slick wrote:
However, in my case, the SWR doesn't change much, while the
INCIDENT power does!!!


Guess I wasn't clear. There are an infinite number of impedances
on a constant SWR circle. The transmitter likes some of those
impedances better than others.
--
73, Cecil http://www.qsl.net/w5dxp



-----= Posted via Newsfeeds.Com, Uncensored Usenet News =-----
http://www.newsfeeds.com - The #1 Newsgroup Service in the World!
-----== Over 80,000 Newsgroups - 16 Different Servers! =-----

Tarmo Tammaru August 10th 03 04:04 PM


"Dr. Slick" wrote in message
om...
Someone else suggested that i place the meter
right at the cantenna, to at least exclude the patch from meter to
dummy load.

No, you don't want to do that. Put as much loss as you can between the meter
and the Cantenna. 100 feet of RG58 will have about 6.5 db of loss. It will
make your load a lot closer to 50 Ohms. There are Tables that show SWR as a
function of cable loss for a given mismatch. One chart that I have in
"Reference Data for Radio Engineers" shows that with a load SWR of 1.4, and
6.5 db of cable loss, the SWR at the driving end is around 1.075. Note that
you DO NOT want low loss coax.

Tam/WB2TT



Richard Clark August 10th 03 04:48 PM

On 9 Aug 2003 17:49:36 -0700, (Dr. Slick) wrote:

Hey,

I've been getting different readings on my power meter that
depend on the length of coax that i use to the meter (into a
Cantenna).


On 10 Aug 2003 03:11:06 -0700,
(Dr. Slick) wrote:

However, in my case, the SWR doesn't change much, while the
INCIDENT power does!!! To me, this may be due to the fact that the PA
isn't 50 Ohms at the output


On 10 Aug 2003 03:05:16 -0700,
(Dr. Slick) wrote:


Unfortunately, as i have mentioned before, the cantenna is not the
greatest 50 Ohms at anything above 10-20 MHz.


A classic re-creation of Mismatch Uncertainty already discussed at
great length in the thread "The Cecilian Gambit, a variation on the
Galilean Defense revisited."

Search google for details.

73's
Richard Clark, KB7QHC

Tom Bruhns August 10th 03 05:17 PM

(Dr. Slick) wrote in message . com...
W5DXP wrote in message ...

Remember the maximum power transfer theorem? The transmitter probably works
better into some impedances than into others. With an SWR of 1.4:1, the
transmitter will see a resistance between 35.7 ohms and 70 ohms with a reactance
between zero and about plus or minus j15. Knowing the frequency and VF of the
RG-8X, you should be able to estimate the two impedances seen by the transmitter.



Actually, i read off of my Smith Chart about +/- j20, but you are
close.

Anyhow, my point is that the ham "wife's tale" of adjusting the
coax length for lowest SWR may be truly just a tale.

However, in my case, the SWR doesn't change much, while the
INCIDENT power does!!! To me, this may be due to the fact that the PA
isn't 50 Ohms at the output (I'll bet not many really are), and so a
swing of +/- j20 may improve or degrade how close you are to a
conjugate match.

What do you dudes think?


Instrument it properly and answer your own question. Measure the
power at both ends at the same time. Then, assuming you have good
power meters, calibrated to the line you're using, you'll know if the
input end of the coax also experiences the same power difference. If
it does, then it's presumably the output of the transmitter/filter
that changes. You've already offered a very reasonably hypothesis
about why that happens, and could prove/disprove that through some
measurements, too. Is the transmitter a linear time-invariant system?
(Or does it have a load sensor that reduces power output for some
loads?) Can you determine the actual source impedance of your
amplifier, and correlate that with the readings you've gotten?

I trust that the readings you got weren't much of a surprise...

Cheers,
Tom

Dr. Slick August 11th 03 02:25 AM

"Tarmo Tammaru" wrote in message ...
"Dr. Slick" wrote in message
om...
Someone else suggested that i place the meter
right at the cantenna, to at least exclude the patch from meter to
dummy load.

No, you don't want to do that. Put as much loss as you can between the meter
and the Cantenna. 100 feet of RG58 will have about 6.5 db of loss. It will
make your load a lot closer to 50 Ohms. There are Tables that show SWR as a
function of cable loss for a given mismatch. One chart that I have in
"Reference Data for Radio Engineers" shows that with a load SWR of 1.4, and
6.5 db of cable loss, the SWR at the driving end is around 1.075. Note that
you DO NOT want low loss coax.

Tam/WB2TT



Perhaps you are correct. That you would only want to use the
meter right at the load if you wanted to measure the real SWR of the
antenna, as the coax loss will improve the return loss (SWR).

I'll try a long piece of RG-58 and see how the incident power is
affected.

Slick

Dr. Slick August 11th 03 02:30 AM

W5DXP wrote in message ...
Dr. Slick wrote:
However, in my case, the SWR doesn't change much, while the
INCIDENT power does!!!


Guess I wasn't clear. There are an infinite number of impedances
on a constant SWR circle. The transmitter likes some of those
impedances better than others.



No, i understood you alright, and your statement above is
understood and agreed to.

However, in this case, we only have two impedances to chose from
(two different coax lengths).


Slick

Tom Bruhns August 11th 03 06:30 AM

(Dr. Slick) wrote in message . com...
....
What do you mean by "calibrated to the line"?


The SWR meter should read zero reflected power when connected to a
load whose impedance is equal to the line's. Does it? If not, it's
not properly calibrated. Putting it another way, what's the
directionality of the bridge?

....

Not so much a surprise as a disappointment! A difference of 70
watts incident power is totally unacceptable with only 8 feet of coax
length added.


But the load presented to the amplifier is totally different in the
two cases, most likely. Only if the amplifier's output impedance were
the complex conjugate of the line's, and the line were lossless, and
the amplifier behaved as a linear time-invariant system would you
(should you) expect the power to remain unchanged.

The transmitter does not have a mismatch sensor on it for reducing
power at high SWR. It naturally does output less wattage as the
transconductance is reduced with higher temperatures, but my
measurements were done in close proximity to each other.

Exactly how would you measure the output impedance (S22) of a PA?
Drive it with a small signal (class A, linear mode) in one frequency
(F1), and then inject another frequency (F2) into the output, and then
measure the reflected F2 power? If i remember correctly, that's how
someone was trying to measure S22 at my former place of employment.
But all bets are off as soon as you go non-linear, or non-class A.
S-parameters are supposed to be all small signal.

I don't think you can properly measure the S22 of a class C PA.

Tam brought up the suggestion that i try a really long piece of
RG-58 from meter to dummy load, to make the Cantenna more like 50
Ohms. Gonna try it.


Or just tune the load to zero reflected power after you're sure the
meter is properly calibrated...but that can be a catch-22 situation
that the really long RG-58 can help with. Be aware, though, that
"50-ohm" line seldom is -- it can be off 5 ohms or more. It's a cause
of some consternation to those of us involved in calibration of
precision RF test equipment.

Load-pull techniques are commonly used to characterize RF source
impedances. You make known incremental changes to the load, and
deduce from the change in output power what the source impedance is,
assuming it's a linear time-invariant system. Note that adding length
to a mismatched line is one way to make an incremental change to the
load... I wouldn't necessarily say that the output impedance of a
class C amplifier is meaningless, but it may well not be constant for
all loads. and may depend on parameters you'd have trouble controlling
from day to day.

Cheers,
Tom

Jimmy August 11th 03 08:03 AM

This means your shield has RF on it .
Also triming cable has nothing to do with SWR. Trimming the cable will
change the impedance the transmitter sees if the transmission line has
standing waves on it.


"Dr. Slick" wrote in message
om...
Hey,

I've been getting different readings on my power meter that
depend on the length of coax that i use to the meter (into a
Cantenna).

This is a push-pull VHF 300 watt transmitter with a coax stub
harmonic filter on the output. My digital Daiwa will read about 310
watts incident power using a 4 foot RG-8X jumper coax (from filter to
meter), and about 240 watts using a 12 foot section of RG-8X!!?? VSWR
stays the same at about 1.4:1 .

There is the old ham wife's tale that you can tune your
transmitter for a better match if you adjust the legnth of your coax
to the antenna. And from a theoretical point of view, it _should_ be
only a tale, because if your antenna is not a perfect 50 Ohms, the
length of the coax should still not matter, because the constant VSWR
circles around the center of the Smith Chart have just that, the same
SWR independant of the wavelengths away from the antenna (assuming 50
Ohm transmission lines are used).

OTOH, the actual series equivalent complex impedance will be
alternating from inductive to capacitive, every 1/2 wavelength.
So perhaps this will tune/detune the amplifier?

Any non-bullsh** advice/explainations appreciated.


Dr. Slick




Jimmy August 11th 03 08:08 AM


"Dr. Slick" wrote in message
om...
W5DXP wrote in message

...

Remember the maximum power transfer theorem? The transmitter probably

works
better into some impedances than into others. With an SWR of 1.4:1, the
transmitter will see a resistance between 35.7 ohms and 70 ohms with a

reactance
between zero and about plus or minus j15. Knowing the frequency and VF

of the
RG-8X, you should be able to estimate the two impedances seen by the

transmitter.


Actually, i read off of my Smith Chart about +/- j20, but you are
close.

Anyhow, my point is that the ham "wife's tale" of adjusting the
coax length for lowest SWR may be truly just a tale.


I hope this is a wifes tale that has long been discredited. Trimming cable
changes the impedance seen by the transmitter with no change to SWR. It is
true that there are a lot of people who dont understand the difference.

However, in my case, the SWR doesn't change much, while the
INCIDENT power does!!! To me, this may be due to the fact that the PA
isn't 50 Ohms at the output (I'll bet not many really are), and so a
swing of +/- j20 may improve or degrade how close you are to a
conjugate match.

What do you dudes think?


Dr. Slick




Jimmy August 11th 03 08:18 AM

That would give you 13db of return loss which would be an SWR less than 2:1
even if the far end was a dead short.
Given his current SWR I woud say this would result in a return loss of
around 30db. Numbers are a lot of by guess and by golly but think I am not
too far off.
"Tarmo Tammaru" wrote in message
...

"Dr. Slick" wrote in message
om...
Someone else suggested that i place the meter
right at the cantenna, to at least exclude the patch from meter to
dummy load.

No, you don't want to do that. Put as much loss as you can between the

meter
and the Cantenna. 100 feet of RG58 will have about 6.5 db of loss. It will
make your load a lot closer to 50 Ohms. There are Tables that show SWR as

a
function of cable loss for a given mismatch. One chart that I have in
"Reference Data for Radio Engineers" shows that with a load SWR of 1.4,

and
6.5 db of cable loss, the SWR at the driving end is around 1.075. Note

that
you DO NOT want low loss coax.

Tam/WB2TT





Dr. Slick August 11th 03 11:25 AM

(Tom Bruhns) wrote in message om...
(Dr. Slick) wrote in message . com...
...
What do you mean by "calibrated to the line"?


The SWR meter should read zero reflected power when connected to a
load whose impedance is equal to the line's. Does it? If not, it's
not properly calibrated. Putting it another way, what's the
directionality of the bridge?


You mean the directionality of the couplers inside the meter? I
don't know.
You can adjust the needle on the analog Daiwas to read zero watts with
nothing hooked up to them.



...

Not so much a surprise as a disappointment! A difference of 70
watts incident power is totally unacceptable with only 8 feet of coax
length added.


But the load presented to the amplifier is totally different in the
two cases, most likely. Only if the amplifier's output impedance were
the complex conjugate of the line's, and the line were lossless, and
the amplifier behaved as a linear time-invariant system would you
(should you) expect the power to remain unchanged.



I'm not sure i agree with your statement as you have written it.

The power would remain the same only if the load and the line
were perfect 50 Ohms and also lossless, then the length of the coax
should not matter at all.

This is certainly not the case on our bench, which is a problem,
because i want to have an approximation of how it will perform
attached to the antenna before i ship it out to the customer. A
difference of 70 watts is not acceptable.




Tam brought up the suggestion that i try a really long piece of
RG-58 from meter to dummy load, to make the Cantenna more like 50
Ohms. Gonna try it.


Or just tune the load to zero reflected power after you're sure the
meter is properly calibrated...but that can be a catch-22 situation
that the really long RG-58 can help with. Be aware, though, that
"50-ohm" line seldom is -- it can be off 5 ohms or more. It's a cause
of some consternation to those of us involved in calibration of
precision RF test equipment.


Oh, definitely, especially the cheap stuff. But if the RG-58 went
around the world a couple of times, the end could be open or shorted,
and you would still measure 50 Ohms, most likely.


Load-pull techniques are commonly used to characterize RF source
impedances. You make known incremental changes to the load, and
deduce from the change in output power what the source impedance is,
assuming it's a linear time-invariant system. Note that adding length
to a mismatched line is one way to make an incremental change to the
load... I wouldn't necessarily say that the output impedance of a
class C amplifier is meaningless, but it may well not be constant for
all loads. and may depend on parameters you'd have trouble controlling
from day to day.

Cheers,
Tom



Right, they did plenty of load-pulling on FETS at my former place
of employment. I think they may have been more meaningful for class A
linear CDMA PAs. But finding the max power transfer impedances with
small signal class A measurements doesn't guarantee that these will be
the optimum impedances the transistor wishes to see in class C mode.

But i don't think there is a practical way to measure the S22 of a
high powered Class C amp. Most companies don't really seem to care
how close or far from 50 Ohms it really is, all they care about is the
%PAE and Pout and harmonics dBc going INTO a 50 Ohm system. But even
ensuring that your bench will match your customer's bench is a
difficult thing.


Slick

Tom Bruhns August 11th 03 05:54 PM

(Dr. Slick) wrote in message . com...
....
You mean the directionality of the couplers inside the meter? I
don't know.
You can adjust the needle on the analog Daiwas to read zero watts with
nothing hooked up to them.


:-) The meter-needle zero generally not a very big part of the
problem! Yes, it's the coupler (bridge) inside that you want to make
sure is calibrated for your reference impedance. If it's not
adjustable, at least learn what it is calibrated to, or how good it is
for your reference impedance.

....

But i don't think there is a practical way to measure the S22 of a
high powered Class C amp. Most companies don't really seem to care
how close or far from 50 Ohms it really is, all they care about is the
%PAE and Pout and harmonics dBc going INTO a 50 Ohm system. But even
ensuring that your bench will match your customer's bench is a
difficult thing.


So you've come back around to what some of us here have been saying
for years. A transmitter or amplifier may be designed to work
optimally into some particular impedance (say 50 ohms), but have a
source impedance vastly different from that. Whether it's a
measurable impedance or not is moot: what matters is that you present
a reasonable load to it. There ARE cases where a matched source
impedance is important, but they are rare in ham transmitter work.

The easy way to insure proper operation is to present the
transmitter/amplifier with the right load. A properly calibrated SWR
meter (or as Reg would have it, a "transmitter loading indicator")
will tell you when you have such a load. Yours is telling you that
you do not. In such a case, I'd work on a match to the antenna (or
the Cantenna or whatever) first--well, right after making sure the
meter was telling me the truth or something close to it. When you get
that correct load, then the length of coax won't matter noticably,
assuming the SWR meter is calibrated to the line impedance.

You generally don't have control of your customer's bench, but you can
specify some particular load impedance and then make sure you test
with that, and leave it to the customer to insure that they provide
that load. It's reasonable (if not common) to specify a range of load
impedances over which some perhaps slightly reduced performance is
achieved. You may, for example, get more power but also higher
distortion products, at a non-optimal load.

Cheers,
Tom

Richard Clark August 11th 03 06:12 PM

On 11 Aug 2003 09:54:47 -0700, (Tom Bruhns) wrote:

In such a case, I'd work on a match to the antenna (or
the Cantenna or whatever) first--well, right after making sure the
meter was telling me the truth or something close to it.


Hi Tom,

This is kind of a chicken and egg problem.

Calibrate the meter against the load.

Calibrate the load against the meter.

It would seem that discussion would eventually get around to bringing
in a known and stable reference. The length of lossy line would
suffice for a rough cut solution but still leaves a bench full of
rather sloppy instruments.

73's
Richard Clark, KB7QHC

W5DXP August 11th 03 07:59 PM

Jimmy wrote:
I hope this is a wifes tale that has long been discredited. Trimming cable
changes the impedance seen by the transmitter with no change to SWR.


However, a 50 ohm SWR meter reading will change as one changes the
length of the ladder-line. When the 50 ohm SWR meter reads 1:1,
the transmitter is seeing 50 ohms. That's how I tune my dipole.
--
73, Cecil http://www.qsl.net/w5dxp



-----= Posted via Newsfeeds.Com, Uncensored Usenet News =-----
http://www.newsfeeds.com - The #1 Newsgroup Service in the World!
-----== Over 80,000 Newsgroups - 16 Different Servers! =-----

Dr. Slick August 11th 03 10:24 PM

"Jimmy" wrote in message . com...
This means your shield has RF on it .
Also triming cable has nothing to do with SWR.


In theory, yes. It would be on the constant VSWR circles, assuming
50 Ohm transmission line!

Trimming the cable WILL have something to do with the series
reactance that the PA will see, and may affect the impedance match.


Slick

Dr. Slick August 11th 03 10:31 PM

(Tom Bruhns) wrote in message om...

:-) The meter-needle zero generally not a very big part of the
problem! Yes, it's the coupler (bridge) inside that you want to make
sure is calibrated for your reference impedance. If it's not
adjustable, at least learn what it is calibrated to, or how good it is
for your reference impedance.


It's all supposted to be for 50 Ohms, or course. And that is the
only adjustment on the meter.



The easy way to insure proper operation is to present the
transmitter/amplifier with the right load. A properly calibrated SWR
meter (or as Reg would have it, a "transmitter loading indicator")
will tell you when you have such a load. Yours is telling you that
you do not. In such a case, I'd work on a match to the antenna (or
the Cantenna or whatever) first--well, right after making sure the
meter was telling me the truth or something close to it. When you get
that correct load, then the length of coax won't matter noticably,
assuming the SWR meter is calibrated to the line impedance.


I've never seen an SWR meter that wasn't designed for 50 Ohms...
:/

If you mean adjusting the meter so that the forward power is full
scale deflection, well, that's not needed for a cross-needle SWR
meter.

I'm gonna try the long RG-58 trick...


Slick

August 11th 03 11:42 PM

My 2 cents (wont even buy a lolipop any more!) From the old VHF,er
magazine, couple of thoughts: 1) Very lossey coax will show a prefect
termination impedence even if open, or shorted, if sufficiant length is used
(for the coax's attenuation ) . For that reason, still keep a coil of RG-8
size coax (for power dissipation), with RUBBER DIALECTRIC (was origianlly
made for attenuators at the Microwave Region) Even at 80 meters, with no
load , has very low SWR! At 10 meters, and up, with a UHF connector on one
end, and a N connector, on the other, with NO TERMINATION, makes a great
dummy load to 2-300 watts!. and, 2) Just because you think you have a great
match, can be a random event. to test , place a 1/4 wavelength piece of
coax (figuring with velocity factor). If the SWR stays flat, you can assume
a good match, if, howerer, the SWR climbs, then you need to check for a
proper match ( this will throw the worst condition into your coax , with
this extra length, kinda like the opposite of trimming coax for the best
match legends of old CB lore)! as info, Jim NN7K


"Tom Bruhns" wrote in message
m...
(Dr. Slick) wrote in message

. com...
...
What do you mean by "calibrated to the line"?


The SWR meter should read zero reflected power when connected to a
load whose impedance is equal to the line's. Does it? If not, it's
not properly calibrated. Putting it another way, what's the
directionality of the bridge?

...

Not so much a surprise as a disappointment! A difference of 70
watts incident power is totally unacceptable with only 8 feet of coax
length added.


But the load presented to the amplifier is totally different in the
two cases, most likely. Only if the amplifier's output impedance were
the complex conjugate of the line's, and the line were lossless, and
the amplifier behaved as a linear time-invariant system would you
(should you) expect the power to remain unchanged.

The transmitter does not have a mismatch sensor on it for reducing
power at high SWR. It naturally does output less wattage as the
transconductance is reduced with higher temperatures, but my
measurements were done in close proximity to each other.

Exactly how would you measure the output impedance (S22) of a PA?
Drive it with a small signal (class A, linear mode) in one frequency
(F1), and then inject another frequency (F2) into the output, and then
measure the reflected F2 power? If i remember correctly, that's how
someone was trying to measure S22 at my former place of employment.
But all bets are off as soon as you go non-linear, or non-class A.
S-parameters are supposed to be all small signal.

I don't think you can properly measure the S22 of a class C PA.

Tam brought up the suggestion that i try a really long piece of
RG-58 from meter to dummy load, to make the Cantenna more like 50
Ohms. Gonna try it.


Or just tune the load to zero reflected power after you're sure the
meter is properly calibrated...but that can be a catch-22 situation
that the really long RG-58 can help with. Be aware, though, that
"50-ohm" line seldom is -- it can be off 5 ohms or more. It's a cause
of some consternation to those of us involved in calibration of
precision RF test equipment.

Load-pull techniques are commonly used to characterize RF source
impedances. You make known incremental changes to the load, and
deduce from the change in output power what the source impedance is,
assuming it's a linear time-invariant system. Note that adding length
to a mismatched line is one way to make an incremental change to the
load... I wouldn't necessarily say that the output impedance of a
class C amplifier is meaningless, but it may well not be constant for
all loads. and may depend on parameters you'd have trouble controlling
from day to day.

Cheers,
Tom





Tarmo Tammaru August 12th 03 05:07 AM

Tom

He is trying to measure the output power of an amplifier. His meter is
calibrated for 50 Ohms; so, he needs a 50 Ohm load.

Tam/WB2TT



Dr. Slick August 12th 03 09:05 AM

(Tom Bruhns) wrote in message om...

I'm not sure i agree with your statement as you have written it.

The power would remain the same only if the load and the line
were perfect 50 Ohms and also lossless, then the length of the coax
should not matter at all.


It's true that if the load and line are the same impedance (e.g. 50
ohms), no matter what the line length is, you'll present that
impedance (e.g. 50 ohms) to the source and it will deliver constant
power, independent of line length. If the line is lossless, then the
power delivered to the load will be independent of line length. Fine.
But your OP suggested that the load is NOT the same as the line
impedance (indicated SWR not 1:1), so another case is perhaps equally
or even more interesting.

If you require that the source impedance match the line impedance (and
because the line is lossless, it's impedance must be purely
resistive), then the net power delivered to the line for a given SWR
on the line is invariant with changes in line length (changes in
reflection coefficient angle in the load presented at the source).
(Straightforward though perhaps tedious to prove, or just convince
yourself with some examples.) Since the line is lossless, the power
to the load is invariant. That's the scenario I suggested above.


You're right about this, and it reminds us that if there is any
loss at all, we theoritically move away from a purely resistive
characteristic impedance into a complex one. This furthers the
complexity on the problem, as we must expect reactance in our coax.

We'll have to wait for the room temperature super-conductor that
is also flexible to come closer to the ideal 50 Ohm test setup!



So with a lossless line, and EITHER the load OR the source matched to
the line impedance, the power delivered to the load will be invariant
with line length.


Agreed, as the impedance will not move on the Smith chart.


Slick

Dr. Slick August 12th 03 09:10 AM

(Tom Bruhns) wrote in message om...

This could be a whole 'nuther thread. For a reference, I don't have
any difficulty making a 50 ohm load with 40dB return loss out to a GHz
or so for less than $10, and most of that is the connector. Does
someone need to document how to do that? But I submit that if you
want accurate SWR measurements on a particular line, you should
calibrate your SWR meter to that line, and that doesn't take any
reference except the line itself.

Cheers,
Tom



But can you make a 50 Ohm dummy load with those specs that can
handle
300 Watts? The stays at 50 Ohms out to at least 200 Megs or so?

And i'm still not sure what you mean by "calibrate your SWR meter
to the line". All the SWR meters i have seen are all for 50 Ohms.

Could you tell us the exact procedure?


Slick

Roy Lewallen August 12th 03 10:48 AM

Almost correct.

The transmitter output impedance has no effect whatsoever on the line's SWR.

Roy Lewallen, W7EL

Dr. Slick wrote:
W5DXP wrote in message ...

Jimmy wrote:

I hope this is a wifes tale that has long been discredited. Trimming cable
changes the impedance seen by the transmitter with no change to SWR.


However, a 50 ohm SWR meter reading will change as one changes the
length of the ladder-line. When the 50 ohm SWR meter reads 1:1,
the transmitter is seeing 50 ohms. That's how I tune my dipole.




This is very interesting, as it may indicate that the "wife's
tale" may have some validity in _some_ cases.

For example, if your antenna happens to have an impedance of say,
60 Ohms, and your transmission line happens to NOT be a perfect 50
Ohms (usually the case), and happens to be around 54.8 Ohms or so...
then at odd integer multiples of 1/4 wavelength (velocity factor
included, of course), you will be right on 50 Ohms.

Additionally, as we have mentioned before, PAs rarely have 50 Ohm
output impedances anyways (who actually measures this??). So an
impedance transform via perfect 50 ohm coax length may indeed get you
closer to a conjugate match and higher incident power, which may
improve your VSWR (which is based upon the incident and reflected, of
course).


Slick



Tom Bruhns August 12th 03 04:36 PM

(Dr. Slick) wrote in message . com...
(Tom Bruhns) wrote in message om...

This could be a whole 'nuther thread. For a reference, I don't have
any difficulty making a 50 ohm load with 40dB return loss out to a GHz
or so for less than $10, and most of that is the connector. Does
someone need to document how to do that? But I submit that if you
want accurate SWR measurements on a particular line, you should
calibrate your SWR meter to that line, and that doesn't take any
reference except the line itself.

Cheers,
Tom



But can you make a 50 Ohm dummy load with those specs that can
handle
300 Watts? The stays at 50 Ohms out to at least 200 Megs or so?


50 +/- what? What return loss are you shooting for in this 300W dummy
load? Do you really need 40dB, or is 30dB good enough? I believe
it's possible to bootstrap yourself into measurements that are far
more accurate than you'll need for what you are doing, and do it quite
economically if you don't count your time. But you ought to first ask
yourself just what accuracy you really need, and understand why.

Probably one can make a quite reasonable broadband power load, at
least to your 200MHz limit. There have been some good construction
articles on making tapered shields for power load resistors, for
example, to get good high frequency performance. But if you can make
just a good low-power one, you can bootstrap your way to accurate
measurements at high power. Use the low power one to insure your
directional coupler is good to some tolerance, and use that to tune
your load at whatever frequency you wish to check. Even your cantenna
should be low enough Q when tuned with an L network that it would be
acceptable over the whole of the 2-meter ham band. It's tedious, but
you can re-tune for any spot frequency inside or outside the ham band.
And given one accurate load, you can determine what impedance your
long, lossy coax is and then use that as a dummy load (probably quite
broadband). For example, if your cantenna is good enough through
30MHz, and pretty good at 54MHz, and under 2:1 SWR at 150MHz, then
perhaps enough RG-58 to give you 10dB loss at 150MHz (150 feet or so),
feeding that cantenna, would work fine from 1MHz to 1GHz. Just beware
of power dissipation in the line itself at higher frequencies. You
can even cascade large coax, small coax and the cantenna, to insure
power handling.

Beware of harmonics messing up your readings!

Also, you'd probably do well to consider how small a change in power
results from a modest load change, for various source impedances.
What's the worst case? What's the best? Is there a reason it might
be nice if an amplifier output was "reasonably close" to 50 ohms, or
doesn't it matter at all? If you think all this through, you may
realize that if your dummy load is even only 20dB return loss, it will
be just fine for the measurements you need to make. But YOU should
convince YOURSELF of that, or of what you really do need.

And i'm still not sure what you mean by "calibrate your SWR meter
to the line". All the SWR meters i have seen are all for 50 Ohms.

Could you tell us the exact procedure?


Of course not; I know nothing about YOUR SWR meter. If you understand
how yours works, you should be able to see how to adjust it, though it
may not be worthwhile. To a close approximation, practically all of
them work by sampling the line current and voltage at a point. The
current is somehow turned into a voltage, and if you adjust either the
voltage sampling percentage or the voltage produced by a given
current, you will have adjusted the calibration impedance. At the
high frequency end, you may need to worry about reactive or
phase-shift effects. If it's not adjustable, don't you at least want
to know WHAT impedance it's calibrated for? Or at VERY least, what it
reads with a 50 ohm load?

Cheers,
Tom

Richard Clark August 12th 03 06:41 PM

On Tue, 12 Aug 2003 02:48:49 -0700, Roy Lewallen
wrote:

Almost correct.

The transmitter output impedance has no effect whatsoever on the line's SWR.

Roy Lewallen, W7EL


Hi Roy,

Entirely incorrect.

Transmitter output impedance that does not conform to transmission
line Z, when presented with a mismatched load through that line, adds
mismatch uncertainty in the form of an indeterminate SWR and
indeterminate Power to the load.

This has already been demonstrated twice. This has long been
documented with NBS/NIST references going back 4 decades. There is
nothing mysterious about it at all, and it conforms to the rather
simple principles of wave interference so poorly presented by Cecil in
months past.

The authoritative site:
http://www.boulder.nist.gov/div813/index.html

Direct reference:
"Juroshek, J. R.; A Direct Calibration Method for Measuring
Equivalent Source Mismatch; Microwave J., pp. 106-118;
October 1997

Obscure references:
http://www.boulder.nist.gov/div813/r...00S_n2nNet.pdf
"With vector measurements of the generator and meter reflection
coefficients Ãg and Ãm, respectively, the power of the incident
signal am can be related to the power of the source."

http://www.boulder.nist.gov/div813/r...FRad_ARFTG.pdf
which describes radiometer calibration (perhaps too exotic for this
group)
"tests are based on two assumptions. First, the network responds
linearly to our signal ( no power compression), and second, the
radiometer is sufficiently isolated from the source impedance."
...
"One of the assumptions made in deriving eq. (2) was that the
output from the radiometer is not dependent on the source
impedance. In the construction of the radiometer, two isolators
are inserted at the input of the radiometer to isolate the
radiometer from the source."
...
"The mismatch uncertainty depends strongly on the poorly known
correlation between uncertainties in the measurements of different
reflection coefficients, and so we use the maximum of the
uncertainties obtained by assuming either complete correlation or
no correlation whatsoever."

"Forthcoming Paper: Influence of Impedance Mismatch Effects on
Measurements of Unloaded Q Factors of Transmission Mode Dielectric
Resonators"
IEEE Transaction on Applied Superconductivity

"Analysis of Interconnection Network and Mismatch in the
Nose-to-Nose Calibration
Automatic RF Techniques Group , June 15-16, 2000 , Boston, MA -
June 01, 2000
"We analyze the input networks of the samplers used in the
nose-to-nose calibration method. Our model demonstrates that the
required input network conditions are satisfied in this method and
shows the interconnection errors are limited to measurement
uncertainties of input reflection coefficients and adapter
S-parameters utilized during the calibration procedure. Further,
the input network model fully includes the effects of mismatch
reflections, and we use the model to reconcile nose-to-nose
waveform correction methods with traditional signal power
measurement techniques."

As I mentioned, obscure references. However, given the impetus of
their discussion is long known (and that I have already provided the
original references they rely on), NIST presumes the investigators
already have that basis of knowledge.

73's
Richard Clark, KB7QHC

JDer8745 August 12th 03 07:02 PM

He sed:

"The transmitter output impedance has no effect whatsoever on the line's SWR."

---------

THIS IS ABSOLUTELY CORRECT!

73 Jack

Richard Clark August 12th 03 07:47 PM

On 12 Aug 2003 18:02:19 GMT, (JDer8745) wrote:

He sed:

"The transmitter output impedance has no effect whatsoever on the line's SWR."

---------

THIS IS ABSOLUTELY CORRECT!

73 Jack


Hi Jack,

Hmm, the world of accurate measurement must be wrong then. :-)

It is correct that into a matched load, it makes little difference -
that is not the subject at hand, and as I have said, it has already
been demonstrated twice.

To this point I have seen no counter demonstrations, nor counter
proposals, nor counter argument (no, Jack, yours is not an argument),
nor conflicting bench data. What I have seen are sweeping statements
without any supporting evidence. Given the amateur preference for the
snuggly comfort of illusion, I suppose none of this will change. Not
that I care, it does provide me entertainment (right now in fact) when
astonished correspondents post their plight and are offered responses
of nostrums and head-bobbing. I would offer that it is a joke that
never grows tired - simply because so few would recognize they had a
problem in the first place. In fact, this second demonstration arose
through the naive investigation of a non-amateur. Too many amateurs
consider themselves above such bench activity and too sophisticated to
trod that path.

The flip side of the argument (and why it is so painfully ignored) is
that reveals that most rigs DO exhibit a Z of nearly 50 Ohms such that
this is rarely a problem. It also reveals a shortfall of bench
experience in amateur construction. There was a time when many more
suffered this because they built their own transmitter instead of
passing a credit card across the display case to a sales clerk.

73's
Richard Clark, KB7QHC

W5DXP August 12th 03 08:13 PM

Richard Clark wrote:
To this point I have seen no counter demonstrations, nor counter
proposals, nor counter argument ...


Not unusual since your above deadline for counter demonstrations,
counter proposals, and counter arguments was 66 minutes from the
time you made the original posting. :-)

You are in a room with a 150 ohm (lossless) transmission line coming
through a hole in the wall and with a 50+j0 ohm load in the center of
the room. Are you telling us that the SWR is not (1+|rho|)/(1-|rho|)?
--
73, Cecil http://www.qsl.net/w5dxp



-----= Posted via Newsfeeds.Com, Uncensored Usenet News =-----
http://www.newsfeeds.com - The #1 Newsgroup Service in the World!
-----== Over 80,000 Newsgroups - 16 Different Servers! =-----

Richard Clark August 12th 03 08:28 PM

On Tue, 12 Aug 2003 14:13:44 -0500, W5DXP
wrote:

Richard Clark wrote:
To this point I have seen no counter demonstrations, nor counter
proposals, nor counter argument ...


Not unusual since your above deadline for counter demonstrations,
counter proposals, and counter arguments was 66 minutes from the
time you made the original posting. :-)


Hi Cecil,

I see you still live in a dimensional aberration where you experience
22 days as 66 minutes. You must be oxygen starved by now.

73's
Richard Clark, KB7QHC

Dr. Slick August 12th 03 10:06 PM

(Tom Bruhns) wrote in message om...
(Dr. Slick) wrote in message . com...

But can you make a 50 Ohm dummy load with those specs that can
handle
300 Watts? The stays at 50 Ohms out to at least 200 Megs or so?


50 +/- what? What return loss are you shooting for in this 300W dummy
load? Do you really need 40dB, or is 30dB good enough? I believe
it's possible to bootstrap yourself into measurements that are far
more accurate than you'll need for what you are doing, and do it quite
economically if you don't count your time. But you ought to first ask
yourself just what accuracy you really need, and understand why.


+/- 5 ohms or so. Something that doesn't swing up to 65-70 ohms or
40 ohms.




And i'm still not sure what you mean by "calibrate your SWR meter
to the line". All the SWR meters i have seen are all for 50 Ohms.

Could you tell us the exact procedure?


Of course not; I know nothing about YOUR SWR meter. If you understand
how yours works, you should be able to see how to adjust it, though it
may not be worthwhile.



I didn't think you could tell us. I've never seen an SWR meter
that you could "calibrate" to 50 or 75 ohms, or less.


Slick

Roy Lewallen August 12th 03 10:25 PM

Egad.

Given only a line's characteristic impedance and the load impedance, I
can tell you exactly what the SWR is for a lossless line. For a lossy
line, I only need to know, in addition, the line's length and the amount
of loss per unit length. In no case do I need to know the source impedance.

If, as you insist, the source impedance affects the SWR on the line,
please provide an equation that gives the SWR on the line, with source
impedance being one of the variables. It's such a simple thing, surely
such an equation appears in one of the several references you cite. I
did notice that SWR doesn't appear in any of the titles or the quoted
passages, though, so you may have to dig a little.

And if Cecil's work leads to the conclusion that the source impedance
impacts the line's SWR, then it's wrong.

It is, for those who are interested, very easy to see intuitively why
the source impedance doesn't affect the SWR. Consider the situation that
occurs when the source is first turned on. A forward voltage wave
travels down the line toward the load. A reflected wave, whose magnitude
and phase are determined by the reflection coefficient at the load end
of the line, returns. If we stop time just as the reflected wave is
returning, we can calculate the SWR, so far, on the line, solely from
the ratio of the forward and reflected waves -- it's the interference
between these waves that create the standing waves. Turning time back on
again, the returning wave reflects off the source (assuming a source
mismatch), producing another forward wave. Let's watch this wave as it
travels toward the load, reflects, and returns. Exactly the same
proportion of this wave is reflected as for the original forward wave.
So, when this new forward wave reflects and its reflected wave returns,
we've got a total of two forward waves and two reflected waves. The
forward/reflected ratio of the second pair is exactly the same as the
forward/reflected ratio of the first pair -- it's the reflection
coefficient at the load end. So the ratio of the total forward wave to
the total reverse wave is the same for the first pair, the second pair,
and the sum of the two pairs. In other words, the second pair of waves
hasn't changed the SWR from what we calculated from the original pair of
waves. You can continue this observation for each forward-reverse pair,
and see that the SWR never changes (at least when observed when each
reflected wave just returns) from the original value. And the original
value was determined only by the load mismatch, not the source. The
source mismatch determines how big the total forward and reflected waves
end up being when all the reflections have died out to a negligible
value. But it has nothing to do with the forward/reverse ratio, which
determines the SWR.

Roy Lewallen, W7EL

Richard Clark wrote:
On Tue, 12 Aug 2003 02:48:49 -0700, Roy Lewallen
wrote:


Almost correct.

The transmitter output impedance has no effect whatsoever on the line's SWR.

Roy Lewallen, W7EL



Hi Roy,

Entirely incorrect.

Transmitter output impedance that does not conform to transmission
line Z, when presented with a mismatched load through that line, adds
mismatch uncertainty in the form of an indeterminate SWR and
indeterminate Power to the load.

This has already been demonstrated twice. This has long been
documented with NBS/NIST references going back 4 decades. There is
nothing mysterious about it at all, and it conforms to the rather
simple principles of wave interference so poorly presented by Cecil in
months past.

The authoritative site:
http://www.boulder.nist.gov/div813/index.html

Direct reference:
"Juroshek, J. R.; A Direct Calibration Method for Measuring
Equivalent Source Mismatch; Microwave J., pp. 106-118;
October 1997

Obscure references:
http://www.boulder.nist.gov/div813/r...00S_n2nNet.pdf
"With vector measurements of the generator and meter reflection
coefficients Ãg and Ãm, respectively, the power of the incident
signal am can be related to the power of the source."

http://www.boulder.nist.gov/div813/r...FRad_ARFTG.pdf
which describes radiometer calibration (perhaps too exotic for this
group)
"tests are based on two assumptions. First, the network responds
linearly to our signal ( no power compression), and second, the
radiometer is sufficiently isolated from the source impedance."
...
"One of the assumptions made in deriving eq. (2) was that the
output from the radiometer is not dependent on the source
impedance. In the construction of the radiometer, two isolators
are inserted at the input of the radiometer to isolate the
radiometer from the source."
...
"The mismatch uncertainty depends strongly on the poorly known
correlation between uncertainties in the measurements of different
reflection coefficients, and so we use the maximum of the
uncertainties obtained by assuming either complete correlation or
no correlation whatsoever."

"Forthcoming Paper: Influence of Impedance Mismatch Effects on
Measurements of Unloaded Q Factors of Transmission Mode Dielectric
Resonators"
IEEE Transaction on Applied Superconductivity

"Analysis of Interconnection Network and Mismatch in the
Nose-to-Nose Calibration
Automatic RF Techniques Group , June 15-16, 2000 , Boston, MA -
June 01, 2000
"We analyze the input networks of the samplers used in the
nose-to-nose calibration method. Our model demonstrates that the
required input network conditions are satisfied in this method and
shows the interconnection errors are limited to measurement
uncertainties of input reflection coefficients and adapter
S-parameters utilized during the calibration procedure. Further,
the input network model fully includes the effects of mismatch
reflections, and we use the model to reconcile nose-to-nose
waveform correction methods with traditional signal power
measurement techniques."

As I mentioned, obscure references. However, given the impetus of
their discussion is long known (and that I have already provided the
original references they rely on), NIST presumes the investigators
already have that basis of knowledge.

73's
Richard Clark, KB7QHC



Roy Lewallen August 12th 03 10:32 PM

Sorry, it's not clear from what you've said just what you're trying to
match to what.

Truly, if you connect a 50 ohm load (be it a resistor, or some impedance
transformed by a transmission line, tuner, or other means -- makes no
difference) to a transmitter, and the transmitter's output impedance
isn't 50 ohms, there will be a mismatch at the transmitter output.

But who cares? Most transmitters are designed to work properly when
terminated with 50 ohms, but that doesn't at all mean that their output
impedances are 50 ohms. And it certainly doesn't affect the SWR on any
transmission line connected to the transmitter. If you were to discover
that your transmitter's output impedance were, say, 10 ohms and you
connected it to a 10 ohm load, you'd have a very unhappy transmitter.
All you have to worry about is presenting the transmitter with the load
it was designed to work into, not what the internal impedance of the
transmitter is.

Roy Lewallen, W7EL

Dr. Slick wrote:
Roy Lewallen wrote in message ...

Almost correct.

The transmitter output impedance has no effect whatsoever on the line's SWR.

Roy Lewallen, W7EL




My point is that if the output impedance really was at a perfect
50 Ohms, then using a perfect 50 ohms transmission line, you can never
match to anything other than 50 ohms.

If the S22 is something other than 50 Ohms (usual case), then a
transformation via 50 ohm coax about a constant VSWR is possible, for
the purposes of matching to a not-quite-perfectly-50 ohms antenna.


Slick



W5DXP August 12th 03 11:04 PM

Richard Clark wrote:
I see you still live in a dimensional aberration where you experience
22 days as 66 minutes.


I see that you still ignore the technical questions so I will repeat mine:
Are you saying that SWR doesn't equal (1+|rho|)/(1-|rho|)?
--
73, Cecil http://www.qsl.net/w5dxp



-----= Posted via Newsfeeds.Com, Uncensored Usenet News =-----
http://www.newsfeeds.com - The #1 Newsgroup Service in the World!
-----== Over 80,000 Newsgroups - 16 Different Servers! =-----

W5DXP August 12th 03 11:20 PM

Dr. Slick wrote:
I didn't think you could tell us. I've never seen an SWR meter
that you could "calibrate" to 50 or 75 ohms, or less.


The calibration of the SWR meter is controlled by the internal sampling
load resistor, the 'R' in Peter's V + IR equation. I have a home-brewed
SWR meter that measures SWR on both balanced 450 ohm feedlines and on
300 ohm feedlines simply by changing the internal load resistors.
--
73, Cecil http://www.qsl.net/w5dxp



-----= Posted via Newsfeeds.Com, Uncensored Usenet News =-----
http://www.newsfeeds.com - The #1 Newsgroup Service in the World!
-----== Over 80,000 Newsgroups - 16 Different Servers! =-----

Tom Bruhns August 12th 03 11:22 PM

Had a look at the refs. I'm curious, did you actually read the
sentence that Roy wrote?

Cheers,
Tom

Richard Clark wrote in message . ..
On Tue, 12 Aug 2003 02:48:49 -0700, Roy Lewallen
wrote:

Almost correct.

The transmitter output impedance has no effect whatsoever on the line's SWR.

Roy Lewallen, W7EL


Hi Roy,

Entirely incorrect.

Transmitter output impedance that does not conform to transmission
line Z, when presented with a mismatched load through that line, adds
mismatch uncertainty in the form of an indeterminate SWR and
indeterminate Power to the load.

This has already been demonstrated twice. This has long been
documented with NBS/NIST references going back 4 decades. There is
nothing mysterious about it at all, and it conforms to the rather
simple principles of wave interference so poorly presented by Cecil in
months past.

The authoritative site:
http://www.boulder.nist.gov/div813/index.html

Direct reference:
"Juroshek, J. R.; A Direct Calibration Method for Measuring
Equivalent Source Mismatch; Microwave J., pp. 106-118;
October 1997

Obscure references:
http://www.boulder.nist.gov/div813/r...00S_n2nNet.pdf
"With vector measurements of the generator and meter reflection
coefficients Ãg and Ãm, respectively, the power of the incident
signal am can be related to the power of the source."

http://www.boulder.nist.gov/div813/r...FRad_ARFTG.pdf
which describes radiometer calibration (perhaps too exotic for this
group)
"tests are based on two assumptions. First, the network responds
linearly to our signal ( no power compression), and second, the
radiometer is sufficiently isolated from the source impedance."
...
"One of the assumptions made in deriving eq. (2) was that the
output from the radiometer is not dependent on the source
impedance. In the construction of the radiometer, two isolators
are inserted at the input of the radiometer to isolate the
radiometer from the source."
...
"The mismatch uncertainty depends strongly on the poorly known
correlation between uncertainties in the measurements of different
reflection coefficients, and so we use the maximum of the
uncertainties obtained by assuming either complete correlation or
no correlation whatsoever."

"Forthcoming Paper: Influence of Impedance Mismatch Effects on
Measurements of Unloaded Q Factors of Transmission Mode Dielectric
Resonators"
IEEE Transaction on Applied Superconductivity

"Analysis of Interconnection Network and Mismatch in the
Nose-to-Nose Calibration
Automatic RF Techniques Group , June 15-16, 2000 , Boston, MA -
June 01, 2000
"We analyze the input networks of the samplers used in the
nose-to-nose calibration method. Our model demonstrates that the
required input network conditions are satisfied in this method and
shows the interconnection errors are limited to measurement
uncertainties of input reflection coefficients and adapter
S-parameters utilized during the calibration procedure. Further,
the input network model fully includes the effects of mismatch
reflections, and we use the model to reconcile nose-to-nose
waveform correction methods with traditional signal power
measurement techniques."

As I mentioned, obscure references. However, given the impetus of
their discussion is long known (and that I have already provided the
original references they rely on), NIST presumes the investigators
already have that basis of knowledge.

73's
Richard Clark, KB7QHC


Richard Clark August 12th 03 11:24 PM

On Tue, 12 Aug 2003 14:25:47 -0700, Roy Lewallen
wrote:
If, as you insist, the source impedance affects the SWR on the line,
please provide an equation that gives the SWR on the line, with source
impedance being one of the variables.


Hi Roy,

Your crafted requirement reveals the shortfall inherent in the
problem. It is distance based too, and without that discussion there
is no way to forecast what SWR or Power reading you would obtain from
simply knowing both the load and source's Z's. This is why it is
called Mismatch Uncertainty.

I have provided NBS and NIST documents both recently and in the past.
Recent offerings are obscure, as I have already admitted. The earlier
citations I provided were direct and to the point and serve as the
basis of the recent work. I have provided data that exhibits the
effect. I have provided the test protocol in how to achieve that
data. I have also described that this data is also, theoretically,
achievable through standard interference math also presented by me in
the past.

It takes little imagination to observe that there is a zone of
confusion that lies between two reflecting interfaces when the path is
not fully described. My data showed that path in one foot increments
of transmission line over an interval of a quarter wavelength or more.

We have been offered evidence of this Mismatch Uncertainty by Dr.
Slick if I am to trust his postings - be that as it may, because it
requires no further proof.

Simply put, bald assertions that SWR is unaffected when read between
two discontinuities is wrong without a concomitant description of all
paths leading to the SWR meter. This is a commonplace of interference
plain and simple. I have observed no one describing this detail
(except Dr. Slick).

As all this is part of the historical record entitled:
"The Cecilian Gambit, a variation on the Galilean Defense revisited"
I do not see how its repetition here brings anything new to the mix.

None the less, this recent example has been fun. :-)

73's
Richard Clark, KB7QHC