Richard Fry wrote:
"Wes Stewart" wrote (clip): "Reg Edwards" wrote: |Richard Fry wrote - | The generic function of this meter is to measure | the degree of match between a source and a load. |-------------------------------------------------------- |Exactly! Not! The source plays no role at all. The degree of match that is indicated is that between the line (or system Zo) and the load Z. A 50 ohm instrument with a 50 ohm termination shows a reflection coefficient (or whatever mathematical equivalent you want to use) of zero regardless of the source impedance. __________ I wrote "BETWEEN a source and a load," not OF the source and a load. There is a difference. The only difference between those two terms is that "match between" is normal and grammatical technical usage; and "match of" ain't neither. Wes is correct. What the meter measures is the match (expressed as reflection coefficient, SWR, whatever) between the system Zo for which that meter was designed and calibrated, and the load Z. The meter measures nothing that involves the source, except the level of RF that it supplies. It does not respond in any way whatever to the source impedance. -- 73 from Ian G3SEK 'In Practice' columnist for RadCom (RSGB) http://www.ifwtech.co.uk/g3sek |