Jerry August 20th 03 12:14 AM

ladderline underground??
 
Is 450 ohm ladderline effective underground if enclosed in underground PVC
conduit? It would run from the outside of the shack underground to the base
of the antenna, and then run exposed to the feed point of the antenna.

Thanks.

Jerry



CW August 20th 03 01:30 AM

It's about the same as laying it on the ground. You don't think 3/32" of
plastic is going to make any difference do you?
"Jerry" wrote in message ...
Is 450 ohm ladderline effective underground if enclosed in underground PVC
conduit? It would run from the outside of the shack underground to the

base
of the antenna, and then run exposed to the feed point of the antenna.

Thanks.

Jerry





Owen Duffy August 20th 03 01:43 AM



Jerry wrote:
Is 450 ohm ladderline effective underground if enclosed in underground PVC
conduit? It would run from the outside of the shack underground to the base
of the antenna, and then run exposed to the feed point of the antenna.


One of the techniques for terminating a rhombic is to connect the
terminating resistor to the rhombic via a buried transmission line. The
loss on the buried line reduces the power requirements for the
terminating resistor.

Don't know that I would be burying the line to the antenna. If you use a
large enough conduit (dia greater than say 10 times the wire separation)
and the line is supported centrally, and you ensure that it will remain
dry, it might be acceptable - but somehow, I don't think that was what
you had in mind.

Owen


Thanks.

Jerry




Reg Edwards August 20th 03 02:36 AM

Ladder-line will work fine if running down the exact center of a 9- inch or
greater diameter plastic or cast-iron or earthenware pipe provided water is
kept out of it.



Jerry August 20th 03 12:13 PM

Thanks all for the responses. Moisture would be most difficult to keep out.
Moisture in the form of condensation would be a greater problem for it than
the rain, snow, and ice it would be exposed to if it were above ground.
"Jerry" wrote in message ...
Is 450 ohm ladderline effective underground if enclosed in underground PVC
conduit? It would run from the outside of the shack underground to the

base
of the antenna, and then run exposed to the feed point of the antenna.

Thanks.

Jerry