Default ladderline underground??

Is 450 ohm ladderline effective underground if enclosed in underground PVC
conduit? It would run from the outside of the shack underground to the base
of the antenna, and then run exposed to the feed point of the antenna.

Thanks.

Jerry


  #2   Report Post  
Old August 20th 03, 01:30 AM
CW
 
Posts: n/a
Default

It's about the same as laying it on the ground. You don't think 3/32" of
plastic is going to make any difference do you?
"Jerry" wrote in message ...
Is 450 ohm ladderline effective underground if enclosed in underground PVC
conduit? It would run from the outside of the shack underground to the

base
of the antenna, and then run exposed to the feed point of the antenna.

Thanks.

Jerry




  #3   Report Post  
Old August 20th 03, 01:43 AM
Owen Duffy
 
Posts: n/a
Default



Jerry wrote:
Is 450 ohm ladderline effective underground if enclosed in underground PVC
conduit? It would run from the outside of the shack underground to the base
of the antenna, and then run exposed to the feed point of the antenna.


One of the techniques for terminating a rhombic is to connect the
terminating resistor to the rhombic via a buried transmission line. The
loss on the buried line reduces the power requirements for the
terminating resistor.

Don't know that I would be burying the line to the antenna. If you use a
large enough conduit (dia greater than say 10 times the wire separation)
and the line is supported centrally, and you ensure that it will remain
dry, it might be acceptable - but somehow, I don't think that was what
you had in mind.

Owen


Thanks.

Jerry



  #4   Report Post  
Old August 20th 03, 02:36 AM
Reg Edwards
 
Posts: n/a
Default

Ladder-line will work fine if running down the exact center of a 9- inch or
greater diameter plastic or cast-iron or earthenware pipe provided water is
kept out of it.


  #5   Report Post  
Old August 20th 03, 12:13 PM
Jerry
 
Posts: n/a
Default

Thanks all for the responses. Moisture would be most difficult to keep out.
Moisture in the form of condensation would be a greater problem for it than
the rain, snow, and ice it would be exposed to if it were above ground.
"Jerry" wrote in message ...
Is 450 ohm ladderline effective underground if enclosed in underground PVC
conduit? It would run from the outside of the shack underground to the

base
of the antenna, and then run exposed to the feed point of the antenna.

Thanks.

Jerry




Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



All times are GMT +1. The time now is 09:56 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017