Hi gb

St. Louis County, MO (and several municipalities within same) is who
charges additional permit fees for each pull box affixed to the studs
or otherwise properly mounted.

The wiring codes are vastly different for residential, commercial,
schools, hospitals, etc. I know of NO allowance for Romex in any
structure other than residential and even in residential usage,
conduit is still required in several areas.

If I recall correctly, regarding Romex A staple is required within 6
inches of a plastic pull box or 14 inches of a clamped metal pull box.
Some inspectors (whether code or not) will require a staple on ALL
wiring within 6 inches of the pull box, regardless of what kind of
wiring it is. Of course, you know how some inspectors are royal
PITA's.

It's been over 30 years since I worked my way up the ranks and roughly
10 years since I worked in the field. And even then I only worked in
residential. Everything since then was just predication work.

TTUL
Gary

  #2   Report Post  
Old December 12th 04, 04:24 AM
w9gb
 
Posts: n/a
Default

"Gary V. Deutschmann, Sr." wrote in message
...
Hi gb

St. Louis County, MO (and several municipalities within same) is who
charges additional permit fees for each pull box affixed to the studs
or otherwise properly mounted.


OK, that helps ... they should know better .. especially with Emerson
Electric in town and that I believe the IBEW started in St. Louis !

The wiring codes are vastly different for residential, commercial,
schools, hospitals, etc. I know of NO allowance for Romex in any
structure other than residential and even in residential usage,
conduit is still required in several areas.


For residental yes, but I am seeing less of it even in residental.
Much more usage of flexible or rigid conduits ..
although metal vs PVC / composites is a religous war in many areas.

If I recall correctly, regarding Romex A staple is required within 6
inches of a plastic pull box or 14 inches of a clamped metal pull box.
Some inspectors (whether code or not) will require a staple on ALL
wiring within 6 inches of the pull box, regardless of what kind of
wiring it is. Of course, you know how some inspectors are royal
PITA's.


Yup, worked under one for while as summer job. Made me a damn
perfectionist. Very difficult to buy a house these days (better to close my
eyes)

It's been over 30 years since I worked my way up the ranks and roughly
10 years since I worked in the field. And even then I only worked in
residential. Everything since then was just predication work.


It's interesting that since WW2 how the amount of electrical appliances,
computer, etc. in residential and SOHO (small home offices) .. that they are
looking more like commercial every decade !

gb


  #3   Report Post  
Old December 12th 04, 07:54 PM
Gary V. Deutschmann, Sr.
 
Posts: n/a
Default

Hi gb

OK, that helps ... they should know better .. especially with Emerson
Electric in town and that I believe the IBEW started in St. Louis !


It was hard working in St. Louis, we have so many larger companies and
unions controlling the government, that the smaller companies have
virtually no chance of getting ahead.

For residental yes, but I am seeing less of it even in residental.
Much more usage of flexible or rigid conduits ..
although metal vs PVC / composites is a religous war in many areas.


I still prefer metal myself for indoor, PVC for exposed outdoor and
underground installations.
I often use conduit even when not called for, especially in attic runs
where squirrels, etc. might some day be able to get to the wiring.
But within the closed cavity of partition walls, I see no need for
conduit, unless you are considering future additions using same.


Yup, worked under one for while as summer job. Made me a damn
perfectionist. Very difficult to buy a house these days (better to close my
eyes)

Ain't that the truth!


It's interesting that since WW2 how the amount of electrical appliances,
computer, etc. in residential and SOHO (small home offices) .. that they are
looking more like commercial every decade !


That's one of the reasons for so many outlets in my last home!

You may laugh at this, considering it's simple residential wiring.
But every bathroom and/or windowless room that I wired, I ran two
separate lighting branch circuits to each room(s).
If a bathroom had both ceiling lights and vanity lighting, they were
wired on separate branch circuits, so one would not be left in the
dark if one of the breakers was tripped.
Same with long hallways, every other ceiling fixture was on a separate
circuit.

I think I use more electric in my home/office alone than I do in all
the rest of the house, including the kitchen.
Color laser printers and copiers are all on dedicated circuits.
Computers are on their own dedicated circuits, then all the peripheral
components, scanners, hard drives, USB powered ports, etc. all on
another separate circuit.

The nightmare comes in trying to keep both sides of the bus balanced
while keeping spikes from large motors all on one side and away from
the computers.

TTUL
Gary

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Inverted ground plane antenna: compared with normal GP and low dipole. Serge Stroobandt, ON4BAA Antenna 8 February 24th 11 11:22 PM
Mobile Ant L match ? Henry Kolesnik Antenna 14 January 20th 04 05:08 AM
Poor quality low + High TV channels? How much dB in Preamp? lbbs Antenna 16 December 13th 03 04:01 PM
QST Article: An Easy to Build, Dual-Band Collinear Antenna Serge Stroobandt, ON4BAA Antenna 12 October 16th 03 08:44 PM


All times are GMT +1. The time now is 04:00 AM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017