Roy Lewallen wrote in message ...
Quite a number of the things we "know" about transmission lines are actually true only if the assumption is made that Z0 is purely real; that is, they're only approximately true, and only at HF and above with decent cable. Among them are the three I've already mentioned, the simplified formula for Z0, the relationship between power components, and the optimum load impedance. Yet another is that the magnitude of the reflection coefficient is always = 1. That would be only into a passive network. As people mainly concerned with RF issues, we have the luxury of being able to use the simplifying approximation without usually introducing significant errors. But whenever we deal with formulas or situations that have to apply outside this range, we have to remember that it's just an approximation and apply the full analysis instead. Tom, Ian, Bill, and most of the others posting on this thread of course know all this very well. We have to know it in order to do our jobs effectively, and all of us have studied and understood the derivation and basis for Z0 calculation. But I hope it'll be of value to some of the readers who might be misled by statements that "authorities" claim that Z0 is purely real. Roy Lewallen, W7EL No one ever said that Zo is always purely real. But many texts do approximate it this way. Even the ARRL "bible". Slick |