Tarmo Tammaru wrote:
Now for Cecil 1. ZL = 50 - j400. VF=1.62, VR=1.56, SWR=53, PF=1.33W, PR=1.24W. Now for Cecil 2. ZL=50-j400, BUT ZS= 0 + J400. VF=11.2, VR=10.9, SWR=73.7, PF=64W, PR=60.6W. I am at such a high impedance here, that I suspect the 10K sampling resistors are loading down the circuit somewhat. (I might try 100K instead). Note that there is absolutely nothing explicit in the circuit that has anything to do with transmission lines. All components are perfect; there are no stray inductances or stray capacitors. Chipman alludes to such a "phenomenon of resonance" in Chapter 10, "Resonant Transmission Line Circuits". For instance, at a conjugate match point where 100+j100 is seen looking in one direction and 100-j100 is seen looking in the opposite direction, there seems to be a *localized* exchange of extra energy between +j100 and -j100 that can adversely affect the value indicated by an SWR meter placed between those two values. -- 73, Cecil http://www.qsl.net/w5dxp -----= Posted via Newsfeeds.Com, Uncensored Usenet News =----- http://www.newsfeeds.com - The #1 Newsgroup Service in the World! -----== Over 100,000 Newsgroups - 19 Different Servers! =----- |