Tarmo Tammaru wrote:
Interesting situation. You are short by a couple of inches from what one would expect. I wonder if you have to take into account the few inches of line inside the meter. Does the manual say anything about that? Recent MFJ manuals recommend using an external coax T-adapter with a 50 ohm load on one arm, and looking for the dip in SWR reading (short-circuited quarter-wave, or open-circuited half-wave). That does not require accounting for any extra length inside the meter, only inside the T-adapter itself. You should certainly count the length of any connectors/adapters as part of the line length. Certainly. If you don't like math, then plan to install the resonant line in the same way as you tested it, using a T-adapter. -- 73 from Ian G3SEK 'In Practice' columnist for RadCom (RSGB) Editor, 'The VHF/UHF DX Book' http://www.ifwtech.co.uk/g3sek |