With a 1/4wl vertical (mounted close to ground level) and you add a parasitic
(either a reflector or director) do you just ground mount it or do you need radials or does it depend upon the ground conditions? I noticed in running a few simple examples on EZNEC that the impedance drops with the number of parasitics and the spacing. for example the 1/4wl alone will be close to 50 ohms and with a parasitic the impedance will drop to less than half in some arrangements (especially with 0.15wl spacing). Is this due to the interactions of the driven and parasitic element? By the way I was quite impressed by the potential F/B ratio and almost cardioid pattern with a reflector and director added Alan KB7MBI Woodinville, WA |