The loss has nothing to do with the speed of travel, except that the
effective dielectric constant has a direct effect on speed and an indirect effect on loss. At frequencies from at least HF well into the UHF range or higher, the loss in transmission lines having decent insulation (e.g., PE or PTFE) is almost all due to conductor loss rather than dielectric loss. Higher impedance line has lower loss simply because for a given amount of power being conveyed, the current is lower. Therefore, the conductor I^2 * R loss (which is nearly the total loss) is lower. If you introduce a dielectric material (other than air) between conductors, the characteristic impedance drops and the velocity factor increases, due to the same effect. Only in that way are they related in a ladder line. In a coax cable, some of the plastic insulation is sometimes replaced by gas or air to make "foamed" dielectric cable, or by other devices such as plastic disks or a helically wound plastic string. This reduces the effective dielectric constant of the cable, which if the dimensions remained the same, would raise the characteristic impedance. It also increases the velocity factor. In those cables, the characteristic impedance is lowered to its nominal value by increasing the diameter of the center conductor. That is, for a given cable outside diameter and Z0, a cable with more air and less plastic will have a larger center conductor. The larger conductor reduces the I^2 * R loss by decreasing the R. So foam dielectric cable and others having a high velocity factor have lower loss than solid dielectric cables with the same OD because the center conductor is larger. At a frequency of about 1 - 10 GHz or so, dielectric loss begins to dominate, and different relationships exist. The equations describing the relationships among dielectric constant, velocity, impedance, and loss are simple and can be found in a great number of texts. I'm sure they can also be easily found on the web. Roy Lewallen, W7EL Hal Rosser wrote: I've noticed, (but have not studied), some loose relationships in transmission line characteristics (and I guess waveguides fit in here). From an observer's point of view, it seems that a high characteristic impedence line (like 400-ohm or 600-ohm ladder line) also is usually a lower-loss line, and has a higher velocity factor. It also seems that some coax may have a low VF and high loss. Is there a real cause for the relationship of these 3 characteristics of transmission lines ? Is it something we can generalize ? It makes some sense to say that the faster a signal gets through the line, the less loss it will have - and that gives some credence to the relationship in VF and loss being inversely associated. |
VF, low-loss line, high-impedence line - relationship
I've noticed, (but have not studied), some loose relationships in
transmission line characteristics (and I guess waveguides fit in here). From an observer's point of view, it seems that a high characteristic impedence line (like 400-ohm or 600-ohm ladder line) also is usually a lower-loss line, and has a higher velocity factor. It also seems that some coax may have a low VF and high loss. Is there a real cause for the relationship of these 3 characteristics of transmission lines ? Is it something we can generalize ? It makes some sense to say that the faster a signal gets through the line, the less loss it will have - and that gives some credence to the relationship in VF and loss being inversely associated. |
The relationship between the three characteristics is more imaginary
than real. It amounts to little more than an old-wives' tale. The reason attenuation is usually smaller for twin line than coax is because the twin line conductors are usually of greater diameter than the coax inner conductor. And the reason twin line usually has a greater velocity is because the conductors are spaced further apart and usually there's less insulating material between them. But it's quite easy to reverse the situation by obtaining large diameter, high impedance coax and flimsy close-together twin line. ---- Reg, G4FGQ =============================== "Hal Rosser" wrote in message . .. I've noticed, (but have not studied), some loose relationships in transmission line characteristics (and I guess waveguides fit in here). From an observer's point of view, it seems that a high characteristic impedence line (like 400-ohm or 600-ohm ladder line) also is usually a lower-loss line, and has a higher velocity factor. It also seems that some coax may have a low VF and high loss. Is there a real cause for the relationship of these 3 characteristics of transmission lines ? Is it something we can generalize ? It makes some sense to say that the faster a signal gets through the line, the less loss it will have - and that gives some credence to the relationship in VF and loss being inversely associated. |
That makes perfect sense. Just like for power lines - higher voltage means
less loss over the same line. I need to try to use ohms law a little more often. I've wound impedence matching transformers myself - without even thinking about the fact that I was also increasing (or decreasing - depending on the flow) voltage. thanks "Roy Lewallen" wrote in message ... The loss has nothing to do with the speed of travel, except that the effective dielectric constant has a direct effect on speed and an indirect effect on loss. At frequencies from at least HF well into the UHF range or higher, the loss in transmission lines having decent insulation (e.g., PE or PTFE) is almost all due to conductor loss rather than dielectric loss. Higher impedance line has lower loss simply because for a given amount of power being conveyed, the current is lower. Therefore, the conductor I^2 * R loss (which is nearly the total loss) is lower. If you introduce a dielectric material (other than air) between conductors, the characteristic impedance drops and the velocity factor increases, due to the same effect. Only in that way are they related in a ladder line. In a coax cable, some of the plastic insulation is sometimes replaced by gas or air to make "foamed" dielectric cable, or by other devices such as plastic disks or a helically wound plastic string. This reduces the effective dielectric constant of the cable, which if the dimensions remained the same, would raise the characteristic impedance. It also increases the velocity factor. In those cables, the characteristic impedance is lowered to its nominal value by increasing the diameter of the center conductor. That is, for a given cable outside diameter and Z0, a cable with more air and less plastic will have a larger center conductor. The larger conductor reduces the I^2 * R loss by decreasing the R. So foam dielectric cable and others having a high velocity factor have lower loss than solid dielectric cables with the same OD because the center conductor is larger. At a frequency of about 1 - 10 GHz or so, dielectric loss begins to dominate, and different relationships exist. The equations describing the relationships among dielectric constant, velocity, impedance, and loss are simple and can be found in a great number of texts. I'm sure they can also be easily found on the web. Roy Lewallen, W7EL Hal Rosser wrote: I've noticed, (but have not studied), some loose relationships in transmission line characteristics (and I guess waveguides fit in here). From an observer's point of view, it seems that a high characteristic impedence line (like 400-ohm or 600-ohm ladder line) also is usually a lower-loss line, and has a higher velocity factor. It also seems that some coax may have a low VF and high loss. Is there a real cause for the relationship of these 3 characteristics of transmission lines ? Is it something we can generalize ? It makes some sense to say that the faster a signal gets through the line, the less loss it will have - and that gives some credence to the relationship in VF and loss being inversely associated. |
"Reg Edwards" wrote in message ... The relationship between the three characteristics is more imaginary than real. It amounts to little more than an old-wives' tale. The reason attenuation is usually smaller for twin line than coax is because the twin line conductors are usually of greater diameter than the coax inner conductor. *** Thanks - good point and as Roy pointed out - the voltage would be higher - so the loss would be lower. *** And the reason twin line usually has a greater velocity is because the conductors are spaced further apart and usually there's less insulating material between them. **** Does that mean that more insulaton material between the conductors decreases the velocity factor ? Ok - its making more sense. Ladder line just happens to have a high VF and low loss - each for different reasons. **** But it's quite easy to reverse the situation by obtaining large diameter, high impedance coax and flimsy close-together twin line. *** I guess using zip-cord (rubber lamp cord) would be an example. ********* You guys are good. Thanks for the info. |
On Mon, 04 Apr 2005 17:35:37 -0700, Roy Lewallen took
the words right out of my mouth: The loss has nothing to do with the speed of travel, except that the effective dielectric constant has a direct effect on speed and an indirect effect on loss. At frequencies from at least HF well into the UHF range or higher, the loss in transmission lines having decent insulation (e.g., PE or PTFE) is almost all due to conductor loss rather than dielectric loss. Higher impedance line has lower loss simply because for a given amount of power being conveyed, the current is lower. Therefore, the conductor I^2 * R loss (which is nearly the total loss) is lower. If you introduce a dielectric material (other than air) between conductors, the characteristic impedance drops and the velocity factor increases, due to the same effect. Only in that way are they related in a ladder line. In a coax cable, some of the plastic insulation is sometimes replaced by gas or air to make "foamed" dielectric cable, or by other devices such as plastic disks or a helically wound plastic string. This reduces the effective dielectric constant of the cable, which if the dimensions remained the same, would raise the characteristic impedance. It also increases the velocity factor. In those cables, the characteristic impedance is lowered to its nominal value by increasing the diameter of the center conductor. That is, for a given cable outside diameter and Z0, a cable with more air and less plastic will have a larger center conductor. The larger conductor reduces the I^2 * R loss by decreasing the R. So foam dielectric cable and others having a high velocity factor have lower loss than solid dielectric cables with the same OD because the center conductor is larger. At a frequency of about 1 - 10 GHz or so, dielectric loss begins to dominate, and different relationships exist. The equations describing the relationships among dielectric constant, velocity, impedance, and loss are simple and can be found in a great number of texts. I'm sure they can also be easily found on the web. One old wives' tale (*not* attributed to Roy) is that ladderline has lower loss than coax (given as a blanket statement). Therefore, laderline is "good" and coax is "bad." However, compare something like Andrew LDF4-50 to Wireman 554 and you find that the "lossy" coax has a loss of 0.48 dB/100' @ 50 MHz and the "low-loss" ladderline has a loss of 0.41 dB under the same conditions. |
Snip...
But it's quite easy to reverse the situation by obtaining large diameter, high impedance coax and flimsy close-together twin line. *** I guess using zip-cord (rubber lamp cord) would be an example. ********* Snip... The type of lamp cord common in South Africa (don't know about other countries): Two conductors of 0.75mm^2 cross sectional area insulated with about 1mm of white pvc and a spacing of around 2.5mm has an impedance of aproximately 60 Ohms. Close enough to 50 to use for quick&dirty dipoles without balun or tuner. Though have no idea of the velocity factor and don't really need to bother as I just pull apart the cord until I have what looks like enough to get a good swr. Then fine tune by pulling more or cutting. A swr of about 1.3 is achievable. 73 Roger ZR3RC |
Wes Stewart wrote:
However, compare something like Andrew LDF4-50 to Wireman 554 and you find that the "lossy" coax has a loss of 0.48 dB/100' @ 50 MHz and the "low-loss" ladderline has a loss of 0.41 dB under the same conditions. Hi Wes, let's say I'm trying to choose between the two. Wireman 554 is about 25 cents/foot. How much did you say the Andrew LDF4-50 costs? :-) (LMR-1700 is about 8 bucks/foot.) Here's another way to look at things for multi-band non- resonant antenna lengths. The feedpoint impedance for that type antenna may vary from a low of about 50 ohms to a high of about 7500 ohms. To minimize SWR for all conditions, Z0 should equal the square root of those two values or 612 ohms. Given 600 ohm open-wire line, the SWR shouldn't go much above 13:1 for the open-wire line but may go as high as 150:1 for the coax. I don't know about you, but I would rather run with a maximum SWR of 13:1 rather than a maximum SWR of 150:1. -- 73, Cecil http://www.qsl.net/w5dxp ----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups ----= East and West-Coast Server Farms - Total Privacy via Encryption =---- |
Roy Lewallen wrote: .... At frequencies from at least HF well into the UHF range or higher, the loss in transmission lines having decent insulation (e.g., PE or PTFE) is almost all due to conductor loss rather than dielectric loss. Higher impedance line has lower loss simply because for a given amount of power being conveyed, the current is lower. Therefore, the conductor I^2 * R loss (which is nearly the total loss) is lower. If you introduce a dielectric material (other than air) between conductors, the characteristic impedance drops and the velocity factor increases, due to the same effect. Only in that way are they related in a ladder line. Here's a slightly different way to look at the same thing Roy has said. For a given coaxial cable outer conductor diameter, assuming smooth copper conductors, there's a particular ratio of D/d (outer to inner conductor diameters) that gives you the lowest loss. So long as there's negligible loss in the dielectric, that D/d is independent of what dielectric you put in there. But since putting in a dielectric lowers the impedance, the loss goes up as a result of higher current for a given power level. You can put numbers on it pretty easily. Assuming no dielectric loss, the attenuation of the line in dB per unit length is inversely proportional to the line impedance: dB/100ft = 4.34*Rt/Zo, where Rt is the total RF resistance of the wires. But Zo is inversely proportional to the square root of the relative dielectric constant of the dielectric in the line. Putting the two together, for a given conductor configuration (D and d in coax), if there's no loss in the dielectric itself and only loss in the resistance of the wires, the loss in dB/unit length is proportional to the square root of the net effective dielectric constant around the line. Since the velocity factor is inversely proportional to the square root of the same net effective dielectric constant, then for a given configuration of conductors, the loss is indeed dependent on the velocity factor, even with no power dissipated in the dielectric itself. This is true for coax and open wire line in equal measure. But beware that you are more likely to have dielectric loss in open-wire line for a variety of reasons... For lossless dielectric and a fixed conductor configuration (coaxial, two-wire, or other TEM line with fixed conductor sizes and spacings), varying just the dielectric, then, dB/unit length = k1/v.f. = k2/Zo = k3*sqrt(net effective dielectric constant) where k1, k2 and k3 are proportionality constants depending on the conductor configuration. Cheers, Tom |
On Tue, 05 Apr 2005 11:28:46 -0500, Cecil Moore
wrote: |Wes Stewart wrote: | However, compare something like Andrew LDF4-50 to Wireman 554 and you | find that the "lossy" coax has a loss of 0.48 dB/100' @ 50 MHz and the | "low-loss" ladderline has a loss of 0.41 dB under the same conditions. | |Hi Wes, let's say I'm trying to choose between the two. |Wireman 554 is about 25 cents/foot. How much did you say the |Andrew LDF4-50 costs? :-) (LMR-1700 is about 8 bucks/foot.) Typically I buy it at hamfests for $1.00/ft. I have about a dozen short lengths that I bought just for the connectors for $20.00. I also have "in stock" a 110' length of LDF5-50 (7/8") that I paid a guy in San Diego $200 for and a friend brought home to me for free. I've been saving this for a new EME antenna....someday. | |Here's another way to look at things for multi-band non- |resonant antenna lengths. The feedpoint impedance for |that type antenna may vary from a low of about 50 ohms |to a high of about 7500 ohms. To minimize SWR for all |conditions, Z0 should equal the square root of those |two values or 612 ohms. Given 600 ohm open-wire line, |the SWR shouldn't go much above 13:1 for the open-wire |line but may go as high as 150:1 for the coax. I don't |know about you, but I would rather run with a maximum |SWR of 13:1 rather than a maximum SWR of 150:1. Who's talking about multiband non-resonant antennas? I prefer to operate with SWR = 2.0. I can bury my line, strap it to the tower, run it through a hole in the block wall without heartbreak and the only concern I have with rain is that we don't get enough. Furthermore, I don't have concerns with breakage or degradation from UV and the only tuner I need is the one built into the plate circuit of my Drake L-4B. |
Wes Stewart wrote:
|Here's another way to look at things for multi-band non- |resonant antenna lengths. The feedpoint impedance for |that type antenna may vary from a low of about 50 ohms |to a high of about 7500 ohms. To minimize SWR for all |conditions, Z0 should equal the square root of those |two values or 612 ohms. Given 600 ohm open-wire line, |the SWR shouldn't go much above 13:1 for the open-wire |line but may go as high as 150:1 for the coax. I don't |know about you, but I would rather run with a maximum |SWR of 13:1 rather than a maximum SWR of 150:1. Who's talking about multiband non-resonant antennas? Usually, anyone considering ladder-line for the feed system. If the antenna is single-frequency with a 50 ohm feedpoint, there's not much of a reason to even consider ladder-line except for very long runs. -- 73, Cecil http://www.qsl.net/w5dxp ----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups ----= East and West-Coast Server Farms - Total Privacy via Encryption =---- |
K7ITM wrote:
. . . But beware that you are more likely to have dielectric loss in open-wire line for a variety of reasons... . . . Yes, this is something I didn't mention and should have. My statement about the negligibility of dielectric loss below 1 - 10 GHz is strictly true only for coax with decent (common) dielectric material (e.g., PE or PTFE). When the impedance is higher, as it is with ladder line, the effect of the dielectric loss is proportionally higher. On the other hand, a good part of the ladder line field is in the air (although it's most intense directly between conductors, where any insulation typically is), which reduces the effect of loss in the dielectric. Many years ago I measured the attenuation of some common 300 ohm TV twinlead, and found that in some cases when wet its attenuation could exceed that of RG-58 coax. The extra loss is intirely due to degradation of the quality of the dielectric between conductors. See http://eznec.com/Amateur/Articles/Po...Feed_Lines.pdf. I know Wes has done similar measurements on window line and has posted the results at his web site; perhaps he'll remind us again of the URL. Roy Lewallen, W7EL |
The type of lamp cord common in South Africa (don't know about other countries): Two conductors of 0.75mm^2 cross sectional area insulated with about 1mm of white pvc and a spacing of around 2.5mm has an impedance of aproximately 60 Ohms. Close enough to 50 to use for quick&dirty dipoles without balun or tuner. Though have no idea of the velocity factor and don't really need to bother as I just pull apart the cord until I have what looks like enough to get a good swr. Then fine tune by pulling more or cutting. A swr of about 1.3 is achievable. 73 Roger ZR3RC I've heard that lamp cord was low-impedence but had forgotten what the impedence was. Do you just use some tape once you unzip the length you need - to keep it from self-zipping from the tension? I also heard it had a pretty high loss - But like you say - for a quick-and dirty antenna and feedline, its a good trick for a ham's bag. Thanks for the info. |
Hal Rosser wrote:
Do you just use some tape once you unzip the length you need - to keep it from self-zipping from the tension? Just tie a knot at that point. -- 73, Cecil http://www.qsl.net/w5dxp ----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups ----= East and West-Coast Server Farms - Total Privacy via Encryption =---- |
On Tue, 05 Apr 2005 21:55:35 -0500, Cecil Moore
wrote: Hal Rosser wrote: Do you just use some tape once you unzip the length you need - to keep it from self-zipping from the tension? Just tie a knot at that point. Isn't that a differential-mode choke? |
One old wives' tale (*not* attributed to Roy) is that ladderline has lower loss than coax (given as a blanket statement). Therefore, laderline is "good" and coax is "bad." However, compare something like Andrew LDF4-50 to Wireman 554 and you find that the "lossy" coax has a loss of 0.48 dB/100' @ 50 MHz and the "low-loss" ladderline has a loss of 0.41 dB under the same conditions. If they make a coax as low-loss as ladder line, I'll concede you that - but then: Could we agree that ladderline (or window line - or twinlead) has these characteristics: 1. Ladderline (or twinlead or windowline) costs less than an equal length of low-loss coax . 2. The weight of the ladder line would probably be much less than the weight of an equal length of low-loss coax. ---Well, sir - that sells it for me. I'm a cheapskate and I don't like the coax loading down the dipole and stretching it from all that weight. AND I like to play around with something other than the 50-ohm ho-hum stuff. Ham-nerd is a good word, I think. |
From all the responses, I got a lot to think about. Thanks. I got the impression that resistance in the wires is the main cause for loss in a transmission line. NOTE: I recall some line having much higher losses at higher frequencies. (so substitute x for R ??) Another note - I noticed some coax has different capacitance rating per ft. depending on the type and brand, etc. (I thought about using a length of coax for a capacitor in a trap at one time). Question: could some of this loss be caused by the capacitance in the line ? |
On Tue, 05 Apr 2005 18:07:57 -0700, Roy Lewallen
wrote: K7ITM wrote: . . . But beware that you are more likely to have dielectric loss in open-wire line for a variety of reasons... . . . Yes, this is something I didn't mention and should have. My statement about the negligibility of dielectric loss below 1 - 10 GHz is strictly true only for coax with decent (common) dielectric material (e.g., PE or PTFE). When the impedance is higher, as it is with ladder line, the effect of the dielectric loss is proportionally higher. On the other hand, a good part of the ladder line field is in the air (although it's most intense directly between conductors, where any insulation typically is), which reduces the effect of loss in the dielectric. Many years ago I measured the attenuation of some common 300 ohm TV twinlead, and found that in some cases when wet its attenuation could exceed that of RG-58 coax. The extra loss is intirely due to degradation of the quality of the dielectric between conductors. See http://eznec.com/Amateur/Articles/Po...Feed_Lines.pdf. I know Wes has done similar measurements on window line and has posted the results at his web site; perhaps he'll remind us again of the URL. Su http://users.triconet.org/wesandlinda/ladder.htm Wes |
Wes Stewart wrote:
On Tue, 05 Apr 2005 21:55:35 -0500, Cecil Moore wrote: Hal Rosser wrote: Do you just use some tape once you unzip the length you need - to keep it from self-zipping from the tension? Just tie a knot at that point. Isn't that a differential-mode choke? You can make a very good HF common-mode choke by deliberately resonating the inductance of a coil of coax with its self-capacitance... so it seems to follow that a resonant UHF common-mode choke can be made by tying the coax into exactly the right knot. Don't know if it's of any practical use, but it isn't a completely April Fool idea. -- 73 from Ian G3SEK 'In Practice' columnist for RadCom (RSGB) http://www.ifwtech.co.uk/g3sek |
There is no power loss in either pure capacitance or pure inductance.
There is loss only in the resistive (or conductive) components: the RF resistance in the wire and the RF conductance in the dielectric. It is fundamental that the inductance and capacitance in a TEM transmission line are just what cause the energy to propagate from one end to the other...or I suppose if you view it at a higher level, you could say that the same fields which yield the effects we call capacitance and inductance also cause the propagation of energy when they result from a TEM transmission line configuration. I'm sure other valid ways of looking at the situation exist too. (I should also mention that there can be some power lost to radiation, but in most cases that's quite small.) Increased loss at high frequencies comes from several sources: smaller skin depth at higher frequencies means higher resistance in the wires. That goes up as the square root of frequency, once you get to a skin depth which is small compared with the thickness of the copper. Higher frequencies result in higher dielectric loss, though that's generally not an issue below a few GHz. But imperfections along a line can cause significant attenuation because of multiple reflections; dozens of small reflections can add up to a big problem. Cheers, Tom Cheers, Tom |
Question: could some of this loss be caused by the capacitance in
the line ? ================================= Yes. It's another way of looking at it. In addition to current in the load, there is a current which flows between the pair of wires through the capacitance. Increase the capacitance and this current increases. There is negligible loss in the capacitance itself. But the capacitor current has to flow along the wires to get there. And so the additional capacitor-current loss actually occurs in the wire resistance. But this is just the same as saying that loss is greater because the impedance Zo is lower (due to the increase in capacitance). The opposite effect occurs by increasing inductance. An increase in inductance increases Zo and so much reduces attenuation. That's why 88 mH inductive loading coils were used at intervals of 2000 yards at audio frequencies in very long telephone cables. An invention of the great but modest Oliver Heaviside which I think somebody else patented and manufactured by many millions. 88 mH loading coils, spaced at 2000 yards, increases Zo from about 300 ohms to 1100 ohms, thus reducing loss in dB per mile to about one third. ---- Reg, G4FGQ. |
"Hal Rosser" bravely wrote to "All" (04 Apr 05 20:48:04)
--- on the heady topic of "VF, low-loss line, high-impedence line - = relationship" HR Reply-To: "Hal Rosser" HR Xref: aeinews rec.radio.amateur.antenna:27947 HR I've noticed, (but have not studied), some loose relationships in HR transmission line characteristics (and I guess waveguides fit in HR here). From an observer's point of view, it seems that a high HR characteristic impedence line (like 400-ohm or 600-ohm ladder line) HR also is usually a lower-loss line, and has a higher velocity factor. HR It also seems that some coax may have a low VF and high loss. HR Is there a real cause for the relationship of these 3 characteristics HR of transmission lines ? Is it something we can generalize ? HR It makes some sense to say that the faster a signal gets through the HR line, the less loss it will have - and that gives some credence to the HR relationship in VF and loss being inversely associated. You are right there is a connection between wire diameter and spacing. It has to do with the self inductance and resistive losses of two conductors in proximity. By contrast a balanced line has a wider spacing and also allows part of the energy to travel unhindered, so to speak. It helps if the balanced line is designed to be close to the theoretical impedance of free space. The price to pay is that it is more susceptible to the environment. The loss in coax is a trade off to achieve stability. A*s*i*m*o*v .... "Beware of all enterprises that require new clothes." -- THOREAU |
By way of agreeing with what Reg posted about capacitance indirectly
adding to the loss, consider that for any TEM line (twin-lead and coax being two examples), the impedance, Zo, is sqrt(L/C), and the propagation delay, tau, is sqrt(LC) [neglecting the very small contribution of R and G for practical lines at HF and above]. From these two, you can see that C=tau/Zo. If the velocity factor is unity, then tau for a foot of line is one foot divided by the speed of light, about 1.017 nanoseconds. If Zo is 50 ohms, then C for that line would be 20.33pF/foot. If you have line which you know to be 50 ohms and 31.0pF/foot, then you know the v.f. is 20.33/31.0 = 0.656, and by my other recent posting in this thread, you know that its attenuation will be about 1/0.656 = 1.52 times as many dB/unit length as the same line with air dielectric (which would be 50 ohms times 1.52 = 76 ohms). (The interrelation of tau, Z, C, L, line physical length and velocity factor suggests that you can determine Z, for example, by measuring C and v.f. accurately. Some line configurations let you accurately measure conductor diameters as well. You end up with lots of ways to determine a set of line parameters.) But note that a 50 ohm air dielectric coax using the same outer conductor diameter would have a larger inner conductor, but MORE loss than the 76 ohm air dielectric line because of the higher capacitance. Quantitatively, it will have about 1.1 times the dB/unit length loss compared with the 76 ohm line...so the difference in loss between air inslated 50 ohm line and solid polyethylene dielectric 50 ohm line (same OD) will be a ratio of 1.1:1.52, or 1:1.38. Going from 50 ohm line insulated with solid pe to 50 ohm line of the same OD with air insulation will cut the dB loss by about 27%. Going from solid to foamed pe will get you about half that much. There's a bigger effect going from a solid pe 75 ohm line to an air dielectric 75 ohm line, cutting the dB loss by over 42% (assuming I didn't screw up the calcs too badly). Cheers, Tom |
Asimov wrote:
You are right there is a connection between wire diameter and spacing. It has to do with the self inductance and resistive losses of two conductors in proximity. By contrast a balanced line has a wider spacing and also allows part of the energy to travel unhindered, so to speak. Conductors don't "hinder" the traveling of energy. Energy travels just as well along close spaced conductors as it does along wide spaced ones. In fact, loss due to radiation is greater with wider spacing than narrow (although it's still negligible with the lines typically used). It helps if the balanced line is designed to be close to the theoretical impedance of free space. Please explain in what way it "helps". No equation, formula or theoretical treatment I'm aware of shows any advantage, change, or anomaly in tranmission line behavior at a value equal to or near the characteristic impedance of free space. (As has been pointed out many times before in this newsgroup, the impedance of free space is the ratio of E/H fields in a plane wave; the impedance of a transmission line is the ratio of voltage to current of a traveling wave. Although they have the same unit of measure, they're different things -- like foot-pounds of work and foot-pounds of torque.) The price to pay is that it is more susceptible to the environment. Do you mean that lines of approximately 377 ohms impedance are more susceptible to the environment than 200 or 600 ohm lines? In what ways? Why? The loss in coax is a trade off to achieve stability. Coax is more stable than open wire line? Does open wire line drift in some way? A*s*i*m*o*v ... "Beware of all enterprises that require new clothes." -- THOREAU Roy Lewallen, W7EL |
"Hal Rosser" wrote in message . .. The type of lamp cord common in South Africa (don't know about other countries): Two conductors of 0.75mm^2 cross sectional area insulated with about 1mm of white pvc and a spacing of around 2.5mm has an impedance of aproximately 60 Ohms. Close enough to 50 to use for quick&dirty dipoles without balun or tuner. Though have no idea of the velocity factor and don't really need to bother as I just pull apart the cord until I have what looks like enough to get a good swr. Then fine tune by pulling more or cutting. A swr of about 1.3 is achievable. 73 Roger ZR3RC I've heard that lamp cord was low-impedence but had forgotten what the impedence was. Do you just use some tape once you unzip the length you need - to keep it from self-zipping from the tension? I also heard it had a pretty high loss - But like you say - for a quick-and dirty antenna and feedline, its a good trick for a ham's bag. Thanks for the info. Duct tape, insulation tape, etc. or my personal favourite - a cable tie. Confuscious Say: Ham who leaves home without screwdriver, duct tape and cable tie, is same as doctor without stethoscope and syringe. 73 Roger ZR3RC |
"Roy Lewallen" wrote
Energy travels just as well along close spaced conductors as it does along wide spaced ones. In fact, loss due to radiation is greater with wider spacing than narrow ====================================== In fact, the field radiated from correctly balanced twin or open-wire lines is directly proportional to wire spacing. Radiation resistance is the same as a monopole of the same length as the wire spacing in terms of wavelength. Rr even at VHF is quite small. Radiation is off the ends - i.e., in the same direction as the line. Polarisation is in the same direction as the wires are spaced. And, believe it or not, all is independent of the length of the line. ---- Reg, G4FGQ |
Reg Edwards wrote:
And, believe it or not, all is independent of the length of the line. How much does an infinitessimally short line radiate? :-) -- 73, Cecil http://www.qsl.net/w5dxp ----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 100,000 Newsgroups ---= East/West-Coast Server Farms - Total Privacy via Encryption =--- |
"Roy Lewallen" bravely wrote to "All" (06 Apr 05 22:10:02)
--- on the heady topic of " VF, low-loss line, high-impedence line - = relationship" RL From: Roy Lewallen RL Xref: aeinews rec.radio.amateur.antenna:28064 RL Do you mean that lines of approximately 377 ohms impedance are more RL susceptible to the environment than 200 or 600 ohm lines? In what RL ways? Why? Since a portion of the EM field in open wire line is free to travel outside the conductor into the environment then we may safely assume there is an exchange between the environment and the conductor. If the impedance of each is approximately the same then there is less loss in the interface between the two. It has to do with the reflective coefficient where the energy is returned. You will note 300 ohm open line has less loss than 100 ohm open line. RL The loss in coax is a trade off to achieve stability. RL Coax is more stable than open wire line? Does open wire line drift in RL some way? It is susceptible to ambient humidity and proximity to conductive objects (birds, snow, rfi). That is a source of drift in practical terms. A*s*i*m*o*v .... No individual raindrop ever considers itself responsible for the flood |
Cecil,
Almost as much as a "full length" line, if you can feed the power to it. For details check your favorite antenna book. 73, Gene W4SZ Cecil Moore wrote: Reg Edwards wrote: And, believe it or not, all is independent of the length of the line. How much does an infinitessimally short line radiate? :-) -- 73, Cecil http://www.qsl.net/w5dxp |
"Cecil Moore" asks - Reg Edwards wrote: And, believe it or not, all is independent of the length of the line. How much does an infinitessimally short line radiate? :-) ============================ Cec, you took the bait. So just exercise a teeny bit of your imagination. Suppose you have a generator directly connected to a load resistance without any line in between. Let the generator and load terminals both be spaced apart by the same distance as the conductors of the non-existent line. The load carries a current along a length equal to the spacing between its terminals. The load, by virtue of its length, possesses radiation resistance. And so radiation occurs with zero line length. Even a CB-er can understand the obvious. Can you calculate radiating efficiency? ---- Reg, G4FGQ |
Asimov wrote:
Since a portion of the EM field in open wire line is free to travel outside the conductor into the environment then we may safely assume there is an exchange between the environment and the conductor. If the conductors are perfectly conducting, no part of the field at all exists within the conductor. With good conductors like copper and at HF and above, there's very little penetration of the conductor by the fields, either electric or magnetic. As far as an "exchange" goes, it sounds like you're trying to describe radiation. If not, what's the phenomenon you're referring to? If the impedance of each is approximately the same then there is less loss in the interface between the two. No, that's not true. First of all, a mismatch doesn't cause loss. Secondly, as I explained in my last posting, the characteristic impedance of a transmission line isn't the same thing as the characteristic impedance of free space. If you were to construct a transmission line with 377 ohms characteristic impedance (numerically the same as the characteristic impedance of free space), the ratio of E/H fields between the conductors probably won't be anywhere near 377 ohms, as it is in a plane wave propagating without wires. It has to do with the reflective coefficient where the energy is returned. Well, no. There isn't a bundle of energy trying to escape the line and bouncing off the air, or bouncing off the air as it travels along the line, or bouncing off the conductors into the air. So reflection coefficient isn't applicable here. You will note 300 ohm open line has less loss than 100 ohm open line. Yes, and 600 ohm line has less loss than 377 ohm line. You'll have to find a way to fit this into your theory if you want to pursue it. RL The loss in coax is a trade off to achieve stability. RL Coax is more stable than open wire line? Does open wire line drift in RL some way? It is susceptible to ambient humidity and proximity to conductive objects (birds, snow, rfi). That is a source of drift in practical terms. Thanks for the clarification. Because the differential fields are completely confined within a coaxial cable, they are indeed more immune to external influences. I'm afraid that the conclusions you've reached about loss and characteristic impedance are based on a poor understanding of fundamental transmission line operation. The result is some conclusions that are, and are well known to be, untrue. If you really feel that you have a viable theory, you should be able to provide some equations and formulas to quantify the extra loss you're talking about. The existing theory, formulas and equations, in daily use for over a hundred years, have been shown countless times to accurately predict transmission line loss, and they don't include the phenomena you're describing. So although I think it's highly doubtful that your formulations will prove more accurate, if you post them they can pretty easily be tested by actual cable measurement. Roy Lewallen, W7EL |
On Thu, 07 Apr 2005 09:09:51 -0500, Cecil Moore
wrote: Reg Edwards wrote: And, believe it or not, all is independent of the length of the line. How much does an infinitessimally short line radiate? :-) Sterba and Feldman in "Transmission Lines for Short-Wave Radio Systems", Proceedings of the IRE, Volume 20, No 7., July, 1932 give a formula for the radiated power in a balanced line. The line length *is* a factor, however, they give a simplified approximation for the case of a length more than 20 times the line spacing and the line spacing less than 1/10 lambda. P/I^2 = 160 * ( pi * D / lambda)^2 whe P is in watts I is the RMS current in a matched line D / lambda is the wire spacing in wavelengths |
"Wes Stewart" wrote The line length *is* a factor, however, they give a simplified approximation for the case of a length more than 20 times the line spacing and the line spacing less than 1/10 lambda. P/I^2 = 160 * ( pi * D / lambda)^2 whe P is in watts I is the RMS current in a matched line D / lambda is the wire spacing in wavelengths =================================== I don't see line length in the formula. What do they say about line lengths less than 20 times wire spacing for small spacings? ---- Reg. |
Wes Stewart wrote: On Thu, 07 Apr 2005 09:09:51 -0500, Cecil Moore wrote: Reg Edwards wrote: And, believe it or not, all is independent of the length of the line. How much does an infinitessimally short line radiate? :-) Sterba and Feldman in "Transmission Lines for Short-Wave Radio Systems", Proceedings of the IRE, Volume 20, No 7., July, 1932 give a formula for the radiated power in a balanced line. The line length *is* a factor, however, they give a simplified approximation for the case of a length more than 20 times the line spacing and the line spacing less than 1/10 lambda. P/I^2 = 160 * ( pi * D / lambda)^2 whe P is in watts I is the RMS current in a matched line D / lambda is the wire spacing in wavelengths |
Reg Edwards wrote:
Cec, you took the bait. So just exercise a teeny bit of your imagination. Suppose you have a generator directly connected to a load resistance without any line in between. Let the generator and load terminals both be spaced apart by the same distance as the conductors of the non-existent line. The load carries a current along a length equal to the spacing between its terminals. The load, by virtue of its length, possesses radiation resistance. And so radiation occurs with zero line length. You've told us about radiation from the connections to the generator and the termination. Now tell us about radiation from the line. -- 73 from Ian G3SEK 'In Practice' columnist for RadCom (RSGB) http://www.ifwtech.co.uk/g3sek |
Reg Edwards wrote:
"Cecil Moore" asks - How much does an infinitessimally short line radiate? :-) Cec, you took the bait. We probably need an adjective to describe line radiation from a line that isn't there. How about "phantom radiation"? You know, like phantom pain from a leg that isn't there? :-) -- 73, Cecil http://www.qsl.net/w5dxp ----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 100,000 Newsgroups ---= East/West-Coast Server Farms - Total Privacy via Encryption =--- |
On Thu, 7 Apr 2005 23:27:29 +0000 (UTC), "Reg Edwards"
wrote: "Wes Stewart" wrote The line length *is* a factor, however, they give a simplified approximation for the case of a length more than 20 times the line spacing and the line spacing less than 1/10 lambda. P/I^2 = 160 * ( pi * D / lambda)^2 whe P is in watts I is the RMS current in a matched line D / lambda is the wire spacing in wavelengths =================================== I don't see line length in the formula. That's because for the condition of length 20 * spacing it drops out. What do they say about line lengths less than 20 times wire spacing for small spacings? They say a whole bunch of things in a complicated formula full of cosine integrals, etc. Too complicated to express here in plain ASCII. I'll try to scan it to pdf and post is somewhere. Wes |
On Fri, 08 Apr 2005 06:05:49 -0700, Wes Stewart
wrote: I'll try to scan it to pdf and post is somewhere. http://www.qsl.net/n7ws/Sterba_Openwire.pdf |
Wes Stewart wrote:
http://www.qsl.net/n7ws/Sterba_Openwire.pdf There seems to be a dotted line for feedline radiation going to zero as feedline length goes to zero. :-) -- 73, Cecil http://www.qsl.net/w5dxp ----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 100,000 Newsgroups ---= East/West-Coast Server Farms - Total Privacy via Encryption =--- |
You've told us about radiation from the connections to the generator and the termination. Now tell us about radiation from the line. ================================= Ian, you are falling into the same sort of trap as old wives who imagine most radiation comes from the middle 1/3rd of a dipole because that's where most of the current is. It is self-misleading to consider the various parts of a radiating system to be separate components which are capable of radiating independently of each other. They can't. A system's behaviour must be treated as a whole. We have already discussed that the power radiated from a generator + twin-line + load is a constant and is independent of line length. Total power radiated is equal to that radiated from a wire having a length equal to line spacing with a radiation resistance appropriate to that length. The location of the radiator, insofar as the far-field is concerned, can be considered to be at the load. The current which flows in the radiator is the same as that flowing in a matched load. And the load current is independent of line length. Mathematically, the only way for the total power radiated to remain constant and independent of line length is for zero radiation from the line. In summary, the system as a whole BEHAVES as if there is NO radiation from the line itself - only from fictitious very short monopoles (or dipoles?) at its ends. ---- Reg, G4FGQ |