Frank Gilliland wrote:
Point is that they are usually calibrated for Z0=50 ohms and are in error when used in Z0 environments differing from Z0=50 ohms, e.g. Z0=75 ohms. The point is that the error is insignificant when the directional coupler is much shorter than the wavelength. Nope, that's not the point at all. It is true that a 50 ohm SWR meter designed for HF may not work on 70 cm but the error I'm talking about is the calibration error in a 50 ohm SWR meter designed for HF and used on HF in, for instance, a Z0 = 450 ohm environment instead of its calibrated-for 50 ohm environment. It works perfectly in a 50 ohm environment at the HF frequency of operation. Here's the proof using a 50 ohm SWR meter: XMTR--1/2WL 450 ohm line--SWR meter--1/2WL 450 ohm line--50 ohm load The 50 ohm SWR meter will read 1:1, nowhere near the actual SWR XMTR--1/4WL 450 ohm line--SWR meter--1/4WL 450 ohm line--50 ohm load The 50 ohm SWR meter will read 81:1, nowhere near the actual SWR An SWR meter calibrated for 450 ohms will correctly read 9:1 in both cases. -- 73, Cecil http://www.qsl.net/w5dxp ----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 100,000 Newsgroups ---= East/West-Coast Server Farms - Total Privacy via Encryption =--- |