Old June 30th 05, 05:56 AM
Cecil Moore
 
Posts: n/a
Default

Roy Lewallen wrote:
There are several
examples at Food for thought.txt available at
http://eznec.com/misc/food_for_thought/.


Regarding errors in the first food_for_thought:

A 100w source equipped with a circulator and load while
looking into an open line, will generate 100w and dissipate
100w in the circulator load. That 100w is definitely not free
power. It can be demonstrated to have made a round trip to
the open end of the feedline and then back to the circulator
load.

The error in your thinking is that the source would see an open
circuit when it is equipped with a circulator and load. It won't.
It will *always* see the Z0 of the feedline as its load (assuming
the circulator load equals Z0). That's the purpose of using
the circulator and load - to allow the source to see a fixed
load equal to Z0.
--
73, Cecil http://www.qsl.net/w5dxp

----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==----
http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups
----= East and West-Coast Server Farms - Total Privacy via Encryption =----


 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



All times are GMT +1. The time now is 09:36 AM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017