On Tue, 08 Nov 2005 23:09:51 GMT, Cecil Moore wrote:

Owen Duffy wrote:
In my 100m of W551 with a 16+j0 load at 30MHz, the loss in one metre
of line nearest the load is over 4%, the good news is that since 75%
of the transmitter power is already lost, the weighted effect of that
4.3% is nearer 1% of tx output.


What the heck is one "metre"? Netscape says that is misspelled and
probably should be corrected to "metro". Why aren't you guys on
the English system?


Met The fundamental base of the metre is the quarter of the
terrestrial meridian, or the distance from the pole to equator, which
has been divided into ten millions of equal parts, one of which is of
the length of the metre.

I think we saw the light before the English, but I think they have a
partial metrication now.

If the loss in each meter is 4%, wouldn't the loss in 100 meters
be 400%? What am I missing?


I did not say "the loss in each meter is 4%", I said "the loss in one
metre of line nearest the load is over 4%".

Firstly, percentage losses on cascaded sections are not additive...
you know that. Losses multiply, dB losses add because adding exponents
is multiply the fundamental quantity.

As I have said before, you seem to be under the misconception that the
overall loss (ie Pin/Pout) per unit length of a transmission line
operating with VSWR1 is constant,

It is not necessarily a constant. It is for a lossless cable, and I
think it probably is for a distortionless cable... but I would have to
check that.

(It is true that the loss per unit length of a transmission line
operating with VSWR=1 is constant.)

We were discussing an example based on Wireman 551 ladder-line. The
dominant factor affecting loss at 30MHz is the series resistance
element. Does it make sense that since in that example, the magnitude
of the current varies by nearly 25:1 along the line, that the I**2*R
loss per unit length along the line is not constant, and will vary by
a factor approaching 625:1?

Owen
--
 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
FS: Coax Connectors & Adapters W6KRC Swap 0 October 6th 05 11:41 PM
The "TRICK" to TV 'type' Coax Cable [Shielded] SWL Loop Antennas {RHF} RHF Antenna 27 November 3rd 04 01:38 PM
The "TRICK" to TV 'type' Coax Cable [Shielded] SWL Loop Antennas {RHF} RHF Shortwave 23 November 3rd 04 01:38 PM
Poor quality low + High TV channels? How much dB in Preamp? lbbs Antenna 16 December 13th 03 03:01 PM
Poor quality low + High TV channels? How much dB in Preamp? lbbs Shortwave 16 December 13th 03 03:01 PM


All times are GMT +1. The time now is 09:35 AM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017