Hi,
I am wanting to check the match efficiency or return loss of a C-Tap matching network that matches 50 Ohms in to 4500 Ohm load with 2.5pF in parallel. Match at single Freqency = 45 MHz. Using a 134nH inductor with Q of approx. 85 My calculations result in Cap to ground = 864pF, Cap to inductor = 102pF I tried the match on the front end of my IF circuit and it appears to tune smoothly and peak ok at 45MHz. I then wanted to measure the return loss to see how good the match is. Using the MJF-269, I get a lousey reading of 0.9dB. (almost everything reflected). Either my calculations are way off base, or I am not using the MJF-269 correctly. I also get lousey SWR (16.5), match efficiency below 5%. I purchased the analyzer ages ago and have only used it to measure Vp of coax till now. Any help appreciated. Thanks |