Use of MJF-269 Analyzer help
Hi,
I am wanting to check the match efficiency or return loss
of a C-Tap matching network that matches 50 Ohms in to 4500 Ohm load
with 2.5pF in parallel. Match at single Freqency = 45 MHz.
Using a 134nH inductor with Q of approx. 85
My calculations result in Cap to ground = 864pF, Cap to inductor = 102pF
I tried the match on the front end of my IF circuit and it appears to
tune smoothly and peak ok at 45MHz.
I then wanted to measure the return loss to see how good the match is.
Using the MJF-269, I get a lousey reading of 0.9dB. (almost everything
reflected).
Either my calculations are way off base, or I am not using the MJF-269
correctly. I also get lousey SWR (16.5), match efficiency below 5%.
I purchased the analyzer ages ago and have only used it to measure Vp of
coax till now.
Any help appreciated.
Thanks
|