Home |
Search |
Today's Posts |
|
#1
![]() |
|||
|
|||
![]()
N4JOY wrote:
Hi -- I recently completed some repair work on a National NC-57. I did the typical replacement of electrolytics, out of tolerance resistors, etc. It was functioning reasonably well beforehand but was in need of some TLC. Following my repair work, I turned the unit on and am only receiving a hum with no RX. I conducted some resistance measurements at all tube sockets and every measurement was nominal (according to my NC-57 manual) except for pin 6 of tube 7 (6V6GT). The manual indicates a resistance reading of 380K ohms and I'm receiving around 50K ohms (same as pin 3 and pin 4). To be honest, I can't see how pin 6 should be 380K ohms. The output transformer primary shunt resistor is 22K ohms and everything is wired correctly at the tube socket. I double checked my work and carefully reviewed the schematics -- everything looks good. I'm really stumped here... Remove the tube. Does the resistance change? --scott -- "C'est un Nagra. C'est suisse, et tres, tres precis." |
#2
![]() |
|||
|
|||
![]()
On Jan 28, 3:03*pm, (Scott Dorsey) wrote:
N4JOY wrote: Hi -- I recently completed some repair work on a National NC-57. *I did the typical replacement of electrolytics, out of tolerance resistors, etc. *It was functioning reasonably well beforehand but was in need of some TLC. *Following my repair work, I turned the unit on and am only receiving a hum with no RX. *I conducted some resistance measurements at all tube sockets and every measurement was nominal (according to my NC-57 manual) except for pin 6 of tube 7 (6V6GT). The manual indicates a resistance reading of 380K ohms and I'm receiving around 50K ohms (same as pin 3 and pin 4). *To be honest, I can't see how pin 6 should be 380K ohms. *The output transformer primary shunt resistor is 22K ohms and everything is wired correctly at the tube socket. *I double checked my work and carefully reviewed the schematics -- everything looks good. *I'm really stumped here... Remove the tube. *Does the resistance change? --scott -- "C'est un Nagra. *C'est suisse, et tres, tres precis." Hi -- the resistance of pin 6 to ground at 6V6 is 67.9K ohms. It remains unchanged when the tube is removed. Thanks, Chris, N4JOY |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
What's the problem? | Policy | |||
Haynie admits to problem, alzheimers victims respond with, "What problem?" | Policy | |||
FA: NATIONAL NC-270 HAM RECEIVER - ONE THE LAST NATIONAL BUILT | Boatanchors | |||
National NCX-5 transmit/receive offset problem | Equipment | |||
National NCX-5 transmit/receive offset problem | Equipment |