Default Hammurlund SP600 S Meter Issues

Hello,

I'm the owner of an SP600 now aligned, and receiving well. The only
issue I'm stuck on is the signal strength meter is not reading. The
AVC (?) side where it reads modulation works when switched in, but no
S reading. This indicates a live meter, but why no signal strength on
any signals? Strong or weak, nothing registers. Any ideas or
suggestions?


Thanks,

GB
  #2   Report Post  
Old June 29th 09, 03:51 AM posted to rec.radio.amateur.boatanchors
external usenet poster
 
First recorded activity by RadioBanter: Oct 2006
Posts: 527
Default Hammurlund SP600 S Meter Issues


"Radiola" wrote in message
...
Hello,

I'm the owner of an SP600 now aligned, and receiving well.
The only
issue I'm stuck on is the signal strength meter is not
reading. The
AVC (?) side where it reads modulation works when switched
in, but no
S reading. This indicates a live meter, but why no signal
strength on
any signals? Strong or weak, nothing registers. Any
ideas or
suggestions?


Thanks,

GB


The S meter reads carrier level at the detector and is
switched off when in Man RF gain contol. Make sure the
momentary meter switch is working properly. You can squirt
some contact cleaner into it around the terminals. I've had
one go dead until cleaned. Other than that make sure the
side of the AVC-MAN switch that connects the meter is good.
Again, some contact cleaner there may fix the problems.
Also, check the meter level adjustment to make sure its not
all the way off and is not open. This is a very simple
circuit and not very much can go wrong with it.
BTW, the meter will vary with the modulation level on
AM because the AVC time constant is so fast. You can slow it
down if you like by hanging a capacitor across the AVC
terminals on the back of the RX. This will also cure low
frequency intermodulation distortion in the audio.




--
Richard Knoppow
Los Angeles
WB6KBL



  #3   Report Post  
Old June 29th 09, 02:11 PM posted to rec.radio.amateur.boatanchors
external usenet poster
 
First recorded activity by RadioBanter: Jun 2007
Posts: 9
Default Hammurlund SP600 S Meter Issues

On Jun 28, 9:51*pm, "Richard Knoppow" wrote:
"Radiola" wrote in message

...



Hello,


I'm the owner of an SP600 now aligned, and receiving well.
The only
issue I'm stuck on is the signal strength meter is not
reading. *The
AVC (?) side where it reads modulation works when switched
in, but no
S reading. *This indicates a live meter, but why no signal
strength on
any signals? *Strong or weak, nothing registers. *Any
ideas or
suggestions?


Thanks,


GB


* * * The S meter reads carrier level at the detector and is
switched off when in Man RF gain contol. Make sure the
momentary meter switch is working properly. You can squirt
some contact cleaner into it around the terminals. I've had
one go dead until cleaned. Other than that make sure the
side of the AVC-MAN switch that connects the meter is good.
Again, some contact cleaner there may fix the problems.
Also, check the meter level adjustment to make sure its not
all the way off and is not open. This is a very simple
circuit and not very much can go wrong with it.
* * * BTW, the meter will vary with the modulation level on
AM because the AVC time constant is so fast. You can slow it
down if you like by hanging a capacitor across the AVC
terminals on the back of the RX. This will also cure low
frequency intermodulation distortion in the audio.

--
Richard Knoppow
Los Angeles
WB6KBL


Thanks Richard,

I will give this a try. There's been a garden variety of contact
problems with this receiver because of where it was stored, so on.
Hopefully this may do the trick. Again, thank you for your help.


Thanks,

GB.
  #4   Report Post  
Old June 29th 09, 03:10 PM posted to rec.radio.amateur.boatanchors
external usenet poster
 
First recorded activity by RadioBanter: Oct 2006
Posts: 527
Default Hammurlund SP600 S Meter Issues


"Radiola" wrote in message
...
On Jun 28, 9:51 pm, "Richard Knoppow"
wrote:
"Radiola" wrote in message

...



Hello,


I'm the owner of an SP600 now aligned, and receiving
well.
The only
issue I'm stuck on is the signal strength meter is not
reading. The
AVC (?) side where it reads modulation works when
switched
in, but no
S reading. This indicates a live meter, but why no
signal
strength on
any signals? Strong or weak, nothing registers. Any
ideas or
suggestions?


Thanks,


GB


The S meter reads carrier level at the detector and is
switched off when in Man RF gain contol. Make sure the
momentary meter switch is working properly. You can squirt
some contact cleaner into it around the terminals. I've
had
one go dead until cleaned. Other than that make sure the
side of the AVC-MAN switch that connects the meter is
good.
Again, some contact cleaner there may fix the problems.
Also, check the meter level adjustment to make sure its
not
all the way off and is not open. This is a very simple
circuit and not very much can go wrong with it.
BTW, the meter will vary with the modulation level on
AM because the AVC time constant is so fast. You can slow
it
down if you like by hanging a capacitor across the AVC
terminals on the back of the RX. This will also cure low
frequency intermodulation distortion in the audio.

--
Richard Knoppow
Los Angeles
WB6KBL


Thanks Richard,

I will give this a try. There's been a garden variety of
contact
problems with this receiver because of where it was stored,
so on.
Hopefully this may do the trick. Again, thank you for your
help.


Thanks,

GB.

First thing make sure the RF Meter adjustment on the
back is turned up. If turned down all the way the meter
won't register.
SP-600s are great receivers.




--
Richard Knoppow
Los Angeles
WB6KBL



  #5   Report Post  
Old June 30th 09, 03:33 PM posted to rec.radio.amateur.boatanchors
external usenet poster
 
First recorded activity by RadioBanter: Jun 2007
Posts: 9
Default Hammurlund SP600 S Meter Issues

On Jun 29, 9:10*am, "Richard Knoppow" wrote:
"Radiola" wrote in message

...
On Jun 28, 9:51 pm, "Richard Knoppow"



wrote:
"Radiola" wrote in message


...


Hello,


I'm the owner of an SP600 now aligned, and receiving
well.
The only
issue I'm stuck on is the signal strength meter is not
reading. The
AVC (?) side where it reads modulation works when
switched
in, but no
S reading. This indicates a live meter, but why no
signal
strength on
any signals? Strong or weak, nothing registers. Any
ideas or
suggestions?


Thanks,


GB


The S meter reads carrier level at the detector and is
switched off when in Man RF gain contol. Make sure the
momentary meter switch is working properly. You can squirt
some contact cleaner into it around the terminals. I've
had
one go dead until cleaned. Other than that make sure the
side of the AVC-MAN switch that connects the meter is
good.
Again, some contact cleaner there may fix the problems.
Also, check the meter level adjustment to make sure its
not
all the way off and is not open. This is a very simple
circuit and not very much can go wrong with it.
BTW, the meter will vary with the modulation level on
AM because the AVC time constant is so fast. You can slow
it
down if you like by hanging a capacitor across the AVC
terminals on the back of the RX. This will also cure low
frequency intermodulation distortion in the audio.


--
Richard Knoppow
Los Angeles
WB6KBL


Thanks Richard,

I will give this a try. *There's been a garden variety of
contact
problems with this receiver because of where it was stored,
so on.
Hopefully this may do the trick. *Again, thank you for your
help.

Thanks,

GB.

* * * First thing make sure the RF Meter adjustment on the
back is turned up. If turned down all the way the meter
won't register.
* * * SP-600s are great receivers.

--
Richard Knoppow
Los Angeles
WB6KBL


Yes sir, I believe I did that but next time I tackle work on the rig,
I'll look at that as well.


Thanks,

GB.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Need SP600 JX-17 Front Panel Repainted [email protected] Swap 0 February 24th 08 08:54 PM
FA SP600 Cabinet and New ARC-5s Charlie Hugg Swap 0 September 4th 05 04:49 PM
FA: SP600/JX21 "BLACK" Dan Robinson Boatanchors 0 July 19th 04 01:29 AM
FA: SP600/JX21 "BLACK" Dan Robinson Shortwave 1 July 19th 04 01:04 AM
FS: Old tube sockets, 4, 5, 6, 7 pin, Hammurlund, GR, ceramic, phenolic,matching plugs, extenders Al Schapira Boatanchors 0 January 19th 04 10:54 PM


All times are GMT +1. The time now is 11:17 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017