#11
![]() |
|||
|
|||
![]()
If the plate supply has it's own power supply with a separate power
transformer or winding the meter can be placed in the negative lead of the power supply. Be sure to place the meter outside of any bleeder resistors so you don't measure the bleeder current. Thanks for your suggestion, but in my initial message I had mentioned that my power supply is structured in such a way not to permit measuring plate current on the negative lead as it would otherwise be normal to do. As a matter of fact the low-voltage supply is part of the high-voltage supply; they are not separate. Therefore the current flowing in the negative lead is the sum of the currents of the two supplies, and it is then not possible to isolate the plate current of the final tube. Unfortunately no alternative to measuring it on the high-voltage lead. 73 Tony I0JX |
#12
![]() |
|||
|
|||
![]()
Antonio Vernucci wrote:
If the plate supply has it's own power supply with a separate power transformer or winding the meter can be placed in the negative lead of the power supply. Be sure to place the meter outside of any bleeder resistors so you don't measure the bleeder current. Thanks for your suggestion, but in my initial message I had mentioned that my power supply is structured in such a way not to permit measuring plate current on the negative lead as it would otherwise be normal to do. As a matter of fact the low-voltage supply is part of the high-voltage supply; they are not separate. Therefore the current flowing in the negative lead is the sum of the currents of the two supplies, and it is then not possible to isolate the plate current of the final tube. Unfortunately no alternative to measuring it on the high-voltage lead. 73 Tony I0JX Most good panel meters (Triplet, etc) 2" or larger in diameter in thick Bakelite cases having glass windows are probably insulated well enough to safely be used in the high voltage side up to at least 1kv (or more). I wouldn't try it with a cheap imported meter in a thin plastic case and a plastic window. Back in the days when REAL transmitters were housed in relay rack cabinets it was the norm to put an ammeter in the HV lead. Note that trying to switch a single meter between grid, screen, plate, and HV readings (meter is used as a voltmeter and reads voltage across shunts for current) gets tricky, a WELL insulated switch is required with good isolation between selections! Using every other position of a rotary switch and yanking out the unused contacts might have been common. |
#13
![]() |
|||
|
|||
![]()
Most good panel meters (Triplet, etc) 2" or larger in diameter in thick
Bakelite cases having glass windows are probably insulated well enough to safely be used in the high voltage side up to at least 1kv (or more). I wouldn't try it with a cheap imported meter in a thin plastic case and a plastic window. Back in the days when REAL transmitters were housed in relay rack cabinets it was the norm to put an ammeter in the HV lead. Note that trying to switch a single meter between grid, screen, plate, and HV readings (meter is used as a voltmeter and reads voltage across shunts for current) gets tricky, a WELL insulated switch is required with good isolation between selections! Using every other position of a rotary switch and yanking out the unused contacts might have been common. My Geloso transmitter just adopts the arrangement you mention. But I would prefer to avoid it, mainly because of the HV present on the meter switch. The Hall-effect transducer seems to be perfect for measuring current forgetting about HV. When I will get it I will report whether it really works fine for our applications or not. 73 Tony I0JX |
#14
![]() |
|||
|
|||
![]()
On 15 Jan, 21:43, "Antonio Vernucci" wrote:
Most good panel meters (Triplet, etc) 2" or larger in diameter in thick Bakelite cases having glass windows are probably insulated well enough to safely be used in the high voltage side up to at least 1kv (or more). I wouldn't try it with a cheap imported meter in a thin plastic case and a plastic window. *Back in the days when REAL transmitters were housed in relay rack cabinets it was the norm to put an ammeter in the HV lead. *Note that trying to switch a single meter between grid, screen, plate, and HV readings (meter is used as a voltmeter and reads voltage across shunts for current) gets tricky, a WELL insulated switch is required with good isolation between selections! *Using every other position of a rotary switch and yanking out the unused contacts might have been common. My Geloso transmitter just adopts the arrangement you mention. But I would prefer to avoid it, mainly because of the HV present on the meter switch. The Hall-effect transducer seems to be perfect for measuring current forgetting about HV. When I will get it I will report whether it really works fine for our applications or not. 73 Tony I0JX Tony , I should think it will be ok , may be will need a little rf screening ... as a Idea try using a coax as the plate supply cable , with the braid earthed ... the copper 'should' not affect the magnetic field ... try it out with a low voltage psu and resistor as a load ? G .. |
#15
![]() |
|||
|
|||
![]()
Tony , I should think it will be ok , may be will need a little rf
screening ... as a Idea try using a coax as the plate supply cable , with the braid earthed ... the copper 'should' not affect the magnetic field ... try it out with a low voltage psu and resistor as a load ? G .. I will try but I would not expect RF problems because the Hall transducer will be located inside the modulator screened enclosure and inserted before the modulation transformer where there is plenty of bypass capacitance to ground. 73 Tony I0JX |
#16
![]() |
|||
|
|||
![]()
There are a number of rigs that measure cathode current rather than plate
current. Depending upon the tube, screen current is only a small percentage of plate current, so even a 10% change in screen current may result in only in a 1 or 2% in cathode current. I have one other bizarre thought - which I admit has not been given much thought - suppose you fed the screen with a constant current source, so that screen current would not change at resonance? Also, off this subject and back to screen modulation techniques, the old Radio Handbook mentions that many beam power tubes will self modulate, with no additional screen audio supplied. Apparently, it can vary from tube to tube. Despite that stateement, I know of many am transmitters using beam plate final tubes that do have audio applied to the screen, so take the statement with a grain of salt. 73, Colin K7FM |
#17
![]() |
|||
|
|||
![]()
There are a number of rigs that measure cathode current rather than plate
current. Depending upon the tube, screen current is only a small percentage of plate current, so even a 10% change in screen current may result in only in a 1 or 2% in cathode current. I have one other bizarre thought - which I admit has not been given much thought - suppose you fed the screen with a constant current source, so that screen current would not change at resonance? That was the very initial question of my post. My concern was that tuning for the minimum cathode current may not be as sharp as tuning for the minimum plate current, because when plate current decreases the screen current increases (though only about 1/10 in magnitude). I am not feeding the screen through a resistor from the HV because I do not wish to add a clamp tube to avoid screen voltage rising too much in absence of drive. I am feeding it from a very stable low-voltage supply, so screen current will vary. Also, off this subject and back to screen modulation techniques, the old Radio Handbook mentions that many beam power tubes will self modulate, with no additional screen audio supplied. Apparently, it can vary from tube to tube. Despite that stateement, I know of many am transmitters using beam plate final tubes that do have audio applied to the screen, so take the statement with a grain of salt. The self-modulation method is just the one I am using. I have a 20H choke on the screen path, and that will (I hope so!) self-modulate the screen. I plan to finish work in a month from now. At that time I will be able to report to which extent screen self-modulation works. 73 Tony I0JX Rome, Italy |
#18
![]() |
|||
|
|||
![]()
Antonio Vernucci wrote:
There are a number of rigs that measure cathode current rather than plate current. Depending upon the tube, screen current is only a small percentage of plate current, so even a 10% change in screen current may result in only in a 1 or 2% in cathode current. I have one other bizarre thought - which I admit has not been given much thought - suppose you fed the screen with a constant current source, so that screen current would not change at resonance? That was the very initial question of my post. My concern was that tuning for the minimum cathode current may not be as sharp as tuning for the minimum plate current, because when plate current decreases the screen current increases (though only about 1/10 in magnitude). I am not feeding the screen through a resistor from the HV because I do not wish to add a clamp tube to avoid screen voltage rising too much in absence of drive. I am feeding it from a very stable low-voltage supply, so screen current will vary. Also, off this subject and back to screen modulation techniques, the old Radio Handbook mentions that many beam power tubes will self modulate, with no additional screen audio supplied. Apparently, it can vary from tube to tube. Despite that stateement, I know of many am transmitters using beam plate final tubes that do have audio applied to the screen, so take the statement with a grain of salt. The self-modulation method is just the one I am using. I have a 20H choke on the screen path, and that will (I hope so!) self-modulate the screen. I plan to finish work in a month from now. At that time I will be able to report to which extent screen self-modulation works. 73 Tony I0JX Rome, Italy Depending on the choke inductance value and the final tube you may or may not get full 100% modulation. But it will be close enough for government work and will sound just fine. |
#19
![]() |
|||
|
|||
![]()
Depending on the choke inductance value and the final tube you may or may not
get full 100% modulation. But it will be close enough for government work and will sound just fine. Let'see what will happen. By the way, also the T-368 adopts the self-modulation method. As a matter of fact the screen resistor is connected to the cold side of the modulation transformer. 73 Tony I0JX |
Reply |
|
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Antenna Current Measurement | Antenna | |||
If the plate choke changes value how does it affect the plate tuning capacitor? | Homebrew | |||
If the plate choke changes value how does it affect the plate tuning capacitor? | Equipment | |||
PROBLEM: T4XC DRAKE, NO PLATE CURRENT DIP | Boatanchors | |||
Current in antenna loading coils controversy - new measurement | Antenna |