Default Collins R-188/51J-3 S-Meter Problem and Cure

Thanks for the tip, Richard. I will look for this issue next time my
R-388 has its turn at the main listening position.

73,
Joe


In article ,
"Richard Knoppow" wrote:

I recently aquired an R-388. Its in good condition but
I found the S-meter read very low. From the entries in the
archives of the Collins Collector's List this seems fairly
common. I found that the problem was R-163, a 160ohm
resistor in series with the meter, it had increased in value
to over 200ohms. After replacing it with a good 160ohm film

(snip)
 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
sx-42 s meter problem clive & kristi ingram Boatanchors 5 January 19th 10 11:40 PM
What would you check - A4S 10 meter problem R.Scott Antenna 6 June 3rd 08 02:42 AM
SP-600-JX problem and cure Richard Knoppow Boatanchors 7 February 9th 07 12:05 AM
Question Collins 75A-3 image problem David Austerman Boatanchors 1 August 21st 05 10:47 PM
Collins 32S1 ALC problem K9SQG Boatanchors 0 January 16th 04 03:41 AM