Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Old March 10th 11, 05:20 PM posted to rec.radio.amateur.boatanchors
external usenet poster
 
First recorded activity by RadioBanter: Mar 2011
Posts: 9
Default We need better diagnostics... Heathkit - SB-200 Problem - Help!



On Tue, 8 Mar 2011, K1HL wrote:

My SB-200 works perfectly 80-15 meters. 10 M opened the other day and
I found the SB-200 would not tune. Within 30 seconds one of the
572B's blew out and the breakers both tripped. My exciter, when used
without the SB-200, tunes perfectly on 10 - very low SWR, etc. - so
it's not an antenna issue.
It's got me stumped. Built the linear in 1970 and never had a problem
til this.
Tnx - Harry


We need more diagnostics to come up with better suggestions (I read the
other responses, too).

1. How do you "tune" your amplifier? Are you looking at RF output as you
move the plate tuning knob?

2. Like someone else asked: had you ever had it on 10 meters in the past?

3. How did you perceive one of the 572s blow? (flash of light? filament go
out? noise? smoke/smell?).


Look inside, see if you have a cold solder joint on 10 meter position of
bandswitch?

Get one new 572B and restore to test on other bands, first.

Don't wait 30 seconds before you remove drive.

Use less drive (carrier) next time.

Another possibility is that there was some kind of "short" that developed
inside the tube.

Next time check for output on at least one other band before you try 10
meters again.


  #2   Report Post  
Old March 19th 11, 07:15 PM posted to rec.radio.amateur.boatanchors
external usenet poster
 
First recorded activity by RadioBanter: Aug 2009
Posts: 136
Default We need better diagnostics... Heathkit - SB-200 Problem -Help!

On 03/10/2011 12:20 PM, Art Sowers wrote:


On Tue, 8 Mar 2011, K1HL wrote:

My SB-200 works perfectly 80-15 meters. 10 M opened the other day and
I found the SB-200 would not tune. Within 30 seconds one of the
572B's blew out and the breakers both tripped. My exciter, when used
without the SB-200, tunes perfectly on 10 - very low SWR, etc. - so
it's not an antenna issue.
It's got me stumped. Built the linear in 1970 and never had a problem
til this.
Tnx - Harry


We need more diagnostics to come up with better suggestions (I read the
other responses, too).

1. How do you "tune" your amplifier? Are you looking at RF output as you
move the plate tuning knob?

2. Like someone else asked: had you ever had it on 10 meters in the past?

3. How did you perceive one of the 572s blow? (flash of light? filament
go out? noise? smoke/smell?).


Look inside, see if you have a cold solder joint on 10 meter position of
bandswitch?

Get one new 572B and restore to test on other bands, first.

Don't wait 30 seconds before you remove drive.

Use less drive (carrier) next time.

Another possibility is that there was some kind of "short" that
developed inside the tube.

Next time check for output on at least one other band before you try 10
meters again.


Sounds like a parasitic oscillation problem.
  #3   Report Post  
Old April 7th 11, 03:49 AM posted to rec.radio.amateur.boatanchors
external usenet poster
 
First recorded activity by RadioBanter: Mar 2011
Posts: 3
Default We need better diagnostics... Heathkit - SB-200 Problem - Help!

On Mar 19, 3:15*pm, Kenneth Scharf wrote:
On 03/10/2011 12:20 PM, Art Sowers wrote:





On Tue, 8 Mar 2011, K1HL wrote:


My SB-200 works perfectly 80-15 meters. 10 M opened the other day and
I found the SB-200 would not tune. Within 30 seconds one of the
572B's blew out and the breakers both tripped. My exciter, when used
without the SB-200, tunes perfectly on 10 - very low SWR, etc. - so
it's not an antenna issue.
It's got me stumped. Built the linear in 1970 and never had a problem
til this.
Tnx - Harry


We need more diagnostics to come up with better suggestions (I read the
other responses, too).


1. How do you "tune" your amplifier? Are you looking at RF output as you
move the plate tuning knob?


2. Like someone else asked: had you ever had it on 10 meters in the past?


3. How did you perceive one of the 572s blow? (flash of light? filament
go out? noise? smoke/smell?).


Look inside, see if you have a cold solder joint on 10 meter position of
bandswitch?


Get one new 572B and restore to test on other bands, first.


Don't wait 30 seconds before you remove drive.


Use less drive (carrier) next time.


Another possibility is that there was some kind of "short" that
developed inside the tube.


Next time check for output on at least one other band before you try 10
meters again.


Sounds like a parasitic oscillation problem.


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Heathkit CT-1 problem ? Henry Kolesnik Boatanchors 7 October 10th 07 09:45 PM
Heathkit CT-1 problem ? Henry Kolesnik Homebrew 7 October 10th 07 09:45 PM
Heathkit hw-101 drifting problem gil Boatanchors 2 May 1st 05 08:59 PM
heathkit hr-10 hum problem jwb Boatanchors 1 October 23rd 04 03:46 PM
Heathkit SB-200 Amplifier Problem Help? LJ Boatanchors 10 December 13th 03 03:26 AM


All times are GMT +1. The time now is 05:10 AM.