Old October 30th 03, 12:25 AM
RB
 
Posts: n/a
Default Tek 475 Scope Help???

Hi....recently I picked up an old Tek 475 200Mhz scope not working
I managed to get a full service manual for it but have had no luck getting
it running.

The +50 Volt rail (which I belive all other rails are derived from) is
perfect, as is the 110V, +15, +5 rails.

The negative rails are out, the -8Volt rail reads -6 volts but the -15 Volt
rail is way out at -23 volts.

Im not an expert with this stuff but like to have a go, it would be a shame
to chuck it out.

Its really annoying me because the schematic for the -15 volt supply "looks"
so simple, Ive checked caps, all resistors, transistors and even replaced
the IC (MC1458) with no change at all.

The CRT works fine, lots of brightness, the vertical amps both appear fine
but the timebase is werid, some (lower) ranges wont display a trace at all
and the higher ranges show multiple horizontal line (with no input) and the
trace "curves" to the left hand side of the screen.

If I apply the cal signal input I can see the square wave but triggering is
erratic, reminds me of my first "KnightKit" scope I got when I was a kid
that used a thyratron in the timebase.

Info/parts are a little scarce in this part of the world (Australia)

Does anyone have any hints/suggestions????
Thanks


  #2   Report Post  
Old October 30th 03, 01:55 AM
Steve
 
Posts: n/a
Default

Check the filter caps in the power supply. You've got a terrific scope.
With a little patience and a few caps you'll be up and running.

The erratic sweep could be caused bt dirty contacts on the sweep switch.

Steve

RB wrote in message
...
Hi....recently I picked up an old Tek 475 200Mhz scope not working
I managed to get a full service manual for it but have had no luck getting
it running.

The +50 Volt rail (which I belive all other rails are derived from) is
perfect, as is the 110V, +15, +5 rails.

The negative rails are out, the -8Volt rail reads -6 volts but the -15

Volt
rail is way out at -23 volts.

Im not an expert with this stuff but like to have a go, it would be a

shame
to chuck it out.

Its really annoying me because the schematic for the -15 volt supply

"looks"
so simple, Ive checked caps, all resistors, transistors and even replaced
the IC (MC1458) with no change at all.

The CRT works fine, lots of brightness, the vertical amps both appear fine
but the timebase is werid, some (lower) ranges wont display a trace at all
and the higher ranges show multiple horizontal line (with no input) and

the
trace "curves" to the left hand side of the screen.

If I apply the cal signal input I can see the square wave but triggering

is
erratic, reminds me of my first "KnightKit" scope I got when I was a kid
that used a thyratron in the timebase.

Info/parts are a little scarce in this part of the world (Australia)

Does anyone have any hints/suggestions????
Thanks




  #3   Report Post  
Old October 30th 03, 01:55 AM
Steve
 
Posts: n/a
Default

Check the filter caps in the power supply. You've got a terrific scope.
With a little patience and a few caps you'll be up and running.

The erratic sweep could be caused bt dirty contacts on the sweep switch.

Steve

RB wrote in message
...
Hi....recently I picked up an old Tek 475 200Mhz scope not working
I managed to get a full service manual for it but have had no luck getting
it running.

The +50 Volt rail (which I belive all other rails are derived from) is
perfect, as is the 110V, +15, +5 rails.

The negative rails are out, the -8Volt rail reads -6 volts but the -15

Volt
rail is way out at -23 volts.

Im not an expert with this stuff but like to have a go, it would be a

shame
to chuck it out.

Its really annoying me because the schematic for the -15 volt supply

"looks"
so simple, Ive checked caps, all resistors, transistors and even replaced
the IC (MC1458) with no change at all.

The CRT works fine, lots of brightness, the vertical amps both appear fine
but the timebase is werid, some (lower) ranges wont display a trace at all
and the higher ranges show multiple horizontal line (with no input) and

the
trace "curves" to the left hand side of the screen.

If I apply the cal signal input I can see the square wave but triggering

is
erratic, reminds me of my first "KnightKit" scope I got when I was a kid
that used a thyratron in the timebase.

Info/parts are a little scarce in this part of the world (Australia)

Does anyone have any hints/suggestions????
Thanks




  #4   Report Post  
Old October 30th 03, 06:05 AM
RB
 
Posts: n/a
Default


"RB" wrote in message
...


Thanks to Steve, Jim and Harvey for all the suggestions.
Ive spent a few hours on it today and have got both rails working within
specs.

-15 Volt rail was a crook 1458 Op Amp (some time was wasted trying to
desolder it from the top of the PCB till I realised it was in a socket!

-8 Volt rail was a dud electro.

All working now, triggering perfect upto nearly 400Mhz, only fault is trace
has some 50Hz "wobble" in it, Id say maybe replace all electro's in psu????

Are the values of these electros important????? ie, across the -8Volt rail
Tek have used a 5500uF, at the moment Ive got a 6800uF tacked across the
bottom of the board, Id never be able to find a 5500 cap but could probably
source a 5600 locally...is it that critical???

Thanks again



  #5   Report Post  
Old October 30th 03, 06:05 AM
RB
 
Posts: n/a
Default


"RB" wrote in message
...


Thanks to Steve, Jim and Harvey for all the suggestions.
Ive spent a few hours on it today and have got both rails working within
specs.

-15 Volt rail was a crook 1458 Op Amp (some time was wasted trying to
desolder it from the top of the PCB till I realised it was in a socket!

-8 Volt rail was a dud electro.

All working now, triggering perfect upto nearly 400Mhz, only fault is trace
has some 50Hz "wobble" in it, Id say maybe replace all electro's in psu????

Are the values of these electros important????? ie, across the -8Volt rail
Tek have used a 5500uF, at the moment Ive got a 6800uF tacked across the
bottom of the board, Id never be able to find a 5500 cap but could probably
source a 5600 locally...is it that critical???

Thanks again





  #6   Report Post  
Old October 30th 03, 03:02 PM
Mike Nowlen
 
Posts: n/a
Default

Are the values of these electros important????? ie, across the -8Volt rail
Tek have used a 5500uF, at the moment Ive got a 6800uF tacked across the
bottom of the board, Id never be able to find a 5500 cap but could

probably
source a 5600 locally...is it that critical???


6800uF is plenty close enough.


  #7   Report Post  
Old October 30th 03, 03:02 PM
Mike Nowlen
 
Posts: n/a
Default

Are the values of these electros important????? ie, across the -8Volt rail
Tek have used a 5500uF, at the moment Ive got a 6800uF tacked across the
bottom of the board, Id never be able to find a 5500 cap but could

probably
source a 5600 locally...is it that critical???


6800uF is plenty close enough.


  #8   Report Post  
Old October 30th 03, 05:27 PM
Mike Knudsen
 
Posts: n/a
Default

In article , "RB"
writes:

Are the values of these electros important????? ie, across the -8Volt rail
Tek have used a 5500uF, at the moment Ive got a 6800uF tacked across the
bottom of the board, Id never be able to find a 5500 cap but could probably
source a 5600 locally...is it that critical???


The difference between a 5500 uF and 6800 uF is not critical in a PS. It's
when you go double or more the original value that you get into trouble with
inrush currents being hard on your diodes and blowing fuses. And ISTR those
big Teks have a relay that brings up the power supplies in sequence for extra
protection.
--Mike K.

Oscar loves trash, but hates Spam! Delete him to reply to me.
  #9   Report Post  
Old October 30th 03, 05:27 PM
Mike Knudsen
 
Posts: n/a
Default

In article , "RB"
writes:

Are the values of these electros important????? ie, across the -8Volt rail
Tek have used a 5500uF, at the moment Ive got a 6800uF tacked across the
bottom of the board, Id never be able to find a 5500 cap but could probably
source a 5600 locally...is it that critical???


The difference between a 5500 uF and 6800 uF is not critical in a PS. It's
when you go double or more the original value that you get into trouble with
inrush currents being hard on your diodes and blowing fuses. And ISTR those
big Teks have a relay that brings up the power supplies in sequence for extra
protection.
--Mike K.

Oscar loves trash, but hates Spam! Delete him to reply to me.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
FA: ORIGINAL P&H DL-1 SCOPE MANUAL Bob Rinaldi Boatanchors 0 October 28th 03 03:02 PM
FA: ORIGINAL P&H DL-1 SCOPE MANUAL Bob Rinaldi Boatanchors 0 October 28th 03 03:02 PM
FA: Heathkit SB-614 Monitor scope GS Boatanchors 0 September 19th 03 10:30 PM
FA: Heathkit SB-614 Monitor scope GS Boatanchors 0 September 19th 03 10:30 PM
scope probes Swells8044 Boatanchors 1 August 6th 03 04:22 AM


All times are GMT +1. The time now is 08:42 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017