Howdy - WDØHCO Biz here ...
I am working on a moldie oldie - an old SBE-33 - one of the first transistor/hybrid tube rigs of the mid-60's. This rig was new when "I Dream of Jeannie" was broadcasted on NBC - 42 years ago I think. Well anyway that's what I remembered - the rig is fixed and working great - but every now and then the "PA Load" cap shorts to ground and output goes bye-bye. Old Faust Gonset used a trimmer cap for the PA LOAD. It's an ARCO L305 compression trimmer type - no value on the schematic but I am assuming its 180 mfd by the size. Question is... has anyone worked on this and I am thinkin of pulling the whole thing out and putting a "REAL" variable cap in it's place. Opinions Please... thanks - B |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
FYI: LONG WAIT 4 REPAIRS @ MFJ! | Swap | |||
who repairs Alinco HF? | Swap | |||
Who repairs Sony 2010 | Shortwave | |||
Who Repairs Hallicrafters HT-37? | Boatanchors | |||
Grundig Repairs | Shortwave |