On Tue, 15 Jul 2003 13:10:26 -0500, "Dick, AA5VU"
wrote (with possible editing):

The subject says it all - I have a CDE Ham-IV control head that is
acting up and I recall web page that contains tips on how to trouble
shoot.

Mine light up and the indicator falls to the right side. If I mess with
the brake control it sometimes comes back to live. BTW, It still turns
the beam even thought the indicator is stuck in the South position.

Anyone have the URL on the tip sheet?

73 de Dick, AA5VU


Dick,

Just a guess, but if I remember correctly, the CDE rotors'
meters just measure the voltage across a 500 ohm potentiometer. What
I would do is to disconnect the meter from the rotor and measure the
resistance across the pot and swing arm. Then connect again and move
it, say, 90 degrees or so, then measure again. If you don't get a
reading under 500 ohms and/or it doesn't change, you have a problem in
the rotor. If it reads ok and changes, then the problem is likely in
the control.

73,

Larry W1HJF

  #2   Report Post  
Old July 16th 03, 02:12 PM
L. M. Rappaport
 
Posts: n/a
Default

On Tue, 15 Jul 2003 13:10:26 -0500, "Dick, AA5VU"
wrote (with possible editing):

The subject says it all - I have a CDE Ham-IV control head that is
acting up and I recall web page that contains tips on how to trouble
shoot.

Mine light up and the indicator falls to the right side. If I mess with
the brake control it sometimes comes back to live. BTW, It still turns
the beam even thought the indicator is stuck in the South position.

Anyone have the URL on the tip sheet?

73 de Dick, AA5VU


Dick,

Just a guess, but if I remember correctly, the CDE rotors'
meters just measure the voltage across a 500 ohm potentiometer. What
I would do is to disconnect the meter from the rotor and measure the
resistance across the pot and swing arm. Then connect again and move
it, say, 90 degrees or so, then measure again. If you don't get a
reading under 500 ohms and/or it doesn't change, you have a problem in
the rotor. If it reads ok and changes, then the problem is likely in
the control.

73,

Larry W1HJF

  #3   Report Post  
Old July 16th 03, 04:50 PM
Carl R. Stevenson
 
Posts: n/a
Default


"L. M. Rappaport" wrote in message
...
On Tue, 15 Jul 2003 13:10:26 -0500, "Dick, AA5VU"
wrote (with possible editing):

The subject says it all - I have a CDE Ham-IV control head that is
acting up and I recall web page that contains tips on how to trouble
shoot.

Mine light up and the indicator falls to the right side. If I mess with
the brake control it sometimes comes back to live. BTW, It still turns
the beam even thought the indicator is stuck in the South position.

Anyone have the URL on the tip sheet?

73 de Dick, AA5VU


Dick,

Just a guess, but if I remember correctly, the CDE rotors'
meters just measure the voltage across a 500 ohm potentiometer. What
I would do is to disconnect the meter from the rotor and measure the
resistance across the pot and swing arm. Then connect again and move
it, say, 90 degrees or so, then measure again. If you don't get a
reading under 500 ohms and/or it doesn't change, you have a problem in
the rotor. If it reads ok and changes, then the problem is likely in
the control.

73,

Larry W1HJF


I was also going to venture a WAG that the indicator pot (or wiring to it)
may have "gone south."

The suggestions above are a good way to verify/discount that WAG.

Carl - wk3c

  #4   Report Post  
Old July 16th 03, 04:50 PM
Carl R. Stevenson
 
Posts: n/a
Default


"L. M. Rappaport" wrote in message
...
On Tue, 15 Jul 2003 13:10:26 -0500, "Dick, AA5VU"
wrote (with possible editing):

The subject says it all - I have a CDE Ham-IV control head that is
acting up and I recall web page that contains tips on how to trouble
shoot.

Mine light up and the indicator falls to the right side. If I mess with
the brake control it sometimes comes back to live. BTW, It still turns
the beam even thought the indicator is stuck in the South position.

Anyone have the URL on the tip sheet?

73 de Dick, AA5VU


Dick,

Just a guess, but if I remember correctly, the CDE rotors'
meters just measure the voltage across a 500 ohm potentiometer. What
I would do is to disconnect the meter from the rotor and measure the
resistance across the pot and swing arm. Then connect again and move
it, say, 90 degrees or so, then measure again. If you don't get a
reading under 500 ohms and/or it doesn't change, you have a problem in
the rotor. If it reads ok and changes, then the problem is likely in
the control.

73,

Larry W1HJF


I was also going to venture a WAG that the indicator pot (or wiring to it)
may have "gone south."

The suggestions above are a good way to verify/discount that WAG.

Carl - wk3c

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



All times are GMT +1. The time now is 06:41 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017