Hi All

Idea
IF amp. 9MHz - single ad600 working in sequential mode, AGC realized
with AD8307 and opamp (http://www.mydarc.de/dc4ku/S_Meter.pdf -
bild1)
control voltage for AGC realized with TL431 similar to cdg2000.

Problems
1. - find a simplest way to implement a manual IF control. ("manual"
does NOT mean turning off AGC but possibility to change amplification)

How? Change a control voltage? add a manual regulated stage??? How to
realize threshold?

2. How to changing a time constant of AGC

Any directions or ideas? (www?)

73
MAc
 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
ad8307 Gary Homebrew 3 October 15th 06 09:17 AM
problem ts-870 gianluca Shortwave 0 June 3rd 06 06:40 AM
Haynie admits to problem, alzheimers victims respond with, "What problem?" John Smith Policy 111 June 23rd 05 01:55 AM
A problem PhalanxX General 5 November 11th 04 05:10 AM
IC-746 PRO tx problem steve 73 Equipment 0 October 13th 03 08:56 PM


All times are GMT +1. The time now is 07:56 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017