On Tue, 2 Mar 2010 08:07:13 -0000, Barett wrote:
With he 706 disconnected from the supply I put a new fuse and it blew. I then disconnected all the secondary wires from the transformer and put a new fuse in and it didn't blow. I put the multi meter in series with the mains wire input to the transformer and I got a reading of 300mA with all wires disconnected from the secondary side of the transformer. I left the transformer switched on for a few hours the transformer got too hot to touch and I could smell the heat from it. This is the stage I'm up to at the moment Fred. Shorted windings -- probably in one of the secondary sections. Jonesy -- Marvin L Jones | jonz | W3DHJ | linux 38.24N 104.55W | @ config.com | Jonesy | OS/2 * Killfiling google & XXXXbanter.com: jonz.net/ng.htm |